Thermostats

www.usa.siemens.com/hvaccomponents

A-46

TECH TIPS

Check your order status quickly and easily 
via our secure Order Tracker feature. To take 
advantage of time-saving benefits, go online to 

www.usa.siemens.com/hvaccomponents

click on site360, and register today.

Содержание RAB10.1U

Страница 1: ...Features Fan Speed Switch RAB90 1U for remote switching location 24 277 Vac Two point control algorithm for on off control Line voltage 2 pipe or 4 pipe fan coil applications 3 speed fan control Fan on only models for ventilation Manual or external changeover Two mounting styles electrical wall box or drywall Adjustable upper lower limit stops Dual Fahrenheit Celsius scale Applications The RAB Ele...

Страница 2: ...ty 95 RH Safety UL 873 Wiring Screw Terminals for Wires of 2 x 16 or 1 x 14 AWG 20 AWG max Cover Color White Shipping Weight 0 08 lb 0 18 kg Ordering Note 1 Includes wallplate ARG70 to be UL compliant for switching line voltage Description Part Nos RAB A 77 Accessories Service Kits 3 speed Change Vent Fan Electric Wall Application over ilation Control Switch Box1 Dry Wall 2 pipe Heating Cooling Ve...

Страница 3: ...Wall Plate for Mounting RAB10 1U RAB20 1U and RAB30 1U Dimensions shown in inches mm RAB90 1U and Wall Plate for Mounting 1 10 1 10 1 18 1 18 1 10 0 14 1 18 1 18 1 10 28 3 6 28 30 30 86 86 28 28 30 30 3 39 3 39 TH0491R2 3 80 96 4 3 92 99 6 1 53 38 9 TH0721R1 Wall Plate ARG70 for Mounting ...

Страница 4: ... Thermostat G1 Control Output Fan Speed I G2 Control Output Fan Speed II G3 Control Output Fan Speed III ZV Zone or Thermal Valve W Y Control Output Actuator AS Aqua Sensor RAB20 1U Key T Room Temperature SD Switching Differential SP Room Temperature Setpoint W Valve Output Signal Heating Y Valve Output Signal Cooling Operating Diagrams Heating Mode Cooling Mode ...

Страница 5: ...cal heater Output for three speed fan Dual setpoint temperature scale Control depending on the room or return air temperature remote sensing Automatic Heating Cooling changeover Operating modes Normal Energy Saving Frost Protection and Off Operating mode changeover input for remote control Selectable control parameters Applications The RCC Series of Room Temperature Controllers are typically used ...

Страница 6: ...30 C Setpoint Energy Saving Mode Heating 61 F 16 C Setpoint Energy Saving Mode Cooling 82 F 28 C Operation Temperature 32 to 122 F 0 to 50 C Humidity 95 RH Shipping and Storage Temperature 13 to 158 F 25 to 70 C Humidity 95 RH Agency Approvals UL 873 cUL Certification C22 2 No 24 93 Conforms to CE Requirements Connection Terminals Solid Wires or Prepared Standard Wires 2 X16 AWG or 1 X14 AWG Minim...

Страница 7: ...hangeover Operating modes Normal Energy Saving Freeze Protection and Off Operating mode changeover input for remote control Selectable control parameters Free Energy Band between Heating and Cooling for energy conservation Applications The RCC Series is typically used for the following applications Controlling room temperature in individual rooms that are heated or cooled with four pipe fan coil u...

Страница 8: ...ferential in Heating Mode SDH Selectable 2 or 7 F 1 or 4 C Switching Differential in Cooling Mode SDC 1 or 3 5 F 0 5 or 2 C selectable Dead Zone in Normal Operation 3 5 or 9 F 2 or 5 C Setpoint Energy Saving mode Heating 61 F 16 C Setpoint Energy Saving mode Cooling 82 F 28 C Setpoint Freeze Protection 46 F 8 C Operation Temperature 32 to 122 F 0 to 50 C Humidity 95 RH Shipping and Storage Tempera...

Страница 9: ...ents Thermostats A 45 TH0612R1 3 80 96 6 4 49 114 15 1 88 48 TH0613R1 3 54 90 0 16 4 0 16 4 1 10 28 1 10 28 1 10 28 1 10 28 1 02 26 1 18 30 1 38 35 1 18 30 0 46 11 8 4 09 104 0 16 4 RCC30U FEB Controller Dimensions shown in inches mm Baseplate ...

Страница 10: ...vaccomponents A 46 TECH TIPS Check your order status quickly and easily via our secure Order Tracker feature To take advantage of time saving benefits go online to www usa siemens com hvaccomponents click on site360 and register today ...

Страница 11: ...cooling RCU15U Control depending on room or return air temperature RCU15U Automatic heating cooling changeover RCU15U and RCU50U Manual heating cooling changeover RCU50 2U Operating modes Normal Energy Saving Freeze Protection and Standby RCU15U and RCU50U Operating modes Normal and OFF RCU50 2U Active 0 to 10 Vdc input for setpoint shifting RCU50U Operating mode changeover input for remote contro...

Страница 12: ...10 Vdc Neutral position no setpoint shift 5 Vdc Signal Input Terminals 2 and 3 for Changeover Sensor QAH11 1 safety class 2 NTC resistor 3KΩ 77 F 25 C Maximum Copper Cable Length 16 AWG For Input Signal terminals 1 2 RCU50U 262 feet 80m For Input Signal D1 RCU50U 262 feet 80m Operation Temperature 32 to 122 F 0 to 50 C Humidity 95 RH Shipping and Storage Temperature 13 to 158 F 25 to 70 C Humidity...

Страница 13: ...rential for cooling 2 P 2 position outputs RCU50U Heating Cooling with Minimum Limitation Cooling Key T Room temperature Y10 Output percentage W Room temperature setpoint XpH Proportional band heating XpK Proportional band cooling VR 0 to 100 minimum limitation of cooling output c o Changeover RCU50 2U Heating Cooling Key T Room temperature Y10 Output percentage W Room temperature setpoint XpH Pro...

Страница 14: ...Dimensions Thermostats www usa siemens com hvaccomponents A 50 RCU15 50 Controller Dimensions shown in inches RCU15 50 Baseplate ...

Страница 15: ...limitation for cooling output Operating voltage 24 Vac Ergonomic design Dual Fahrenheit Celsius scale Applications Controlling individual room temperature in HVAC installations that are heated or cooled the RCU61U Temperature Controllers are suited for use with VAV systems with auxiliary heating with VAV compact controllers valve actuators and air damper actuators RCU61U Room Temperature Controlle...

Страница 16: ... Insulation Against Live Voltage 4 kV Maximum Number of Contacts per Panel 50 Status Input B1 Setpoint Shift of 36 F 12 5 C 0 to 10 Vdc Neutral Position No Setpoint Shift 5 Vdc Signal Input B2 for Changeover Sensor QAH11 1 Safety Class 2 Maximum Copper Cable Length 16 AWG For Input Signal B1 B2 RCU61U 262 ft 80 m For Input Signal D1 RCU61U 262 ft 80 m Operation Temperature 32 to 122 F 0 to 50 C Hu...

Страница 17: ...Dimensions www usa siemens com hvaccomponents Thermostats A 53 RCU61U Controller Dimensions shown in inches Baseplate ...

Страница 18: ...vaccomponents A 54 TECH TIPS Check your order status quickly and easily via our secure Order Tracker feature To take advantage of time saving benefits go online to www usa siemens com hvaccomponents click on site360 and register today ...

Страница 19: ...ctuators with selectable operating action of control signals for heating only cooling only or heating and cooling in sequence Relay input for fan pump or other controls Minimum limitation of the supply air temperature Outputs are independently selectable direct acting DA or reverse acting RA Adjustable proportional band Applications Single stage heating Single stage cooling Two stage heating Heati...

Страница 20: ... solid wires or stranded wires 2 x 16 AWG or 1 x 14 AWG Sensor Sensing Element Siemens Ni 1000 Ω at 32 F 0 C Shipping Weight 1 40 lb 0 64 kg Device Combinations Actuators and controls must meet the following specifications Operating voltage 24 Vac Control input modulating 0 to 10 Vdc Description Type Reference OpenAirTM GDE Series Damper Actuator GDE161 1T with 44 lb in torque GDE161 1P OpenAirTM ...

Страница 21: ...ion Diagrams RLA162 5U Room Temperature Controller RLA162 5U and RLM162U Room Temperature Controllers Key N1 Room Temperature Controller RLA162 5U N2 Air Duct Temperature Controller RLM162U controls minimum or maximum limitation of discharge air Y1 Heating valve Y2 Cooling valve ...

Страница 22: ...Dimensions Thermostats www usa siemens com hvaccomponents A 58 RLA162 5U Controller Dimensions shown in inches mm RLA162 5U Baseplate ...

Страница 23: ...des Normal Energy Saving and Off RDU20U and RDU50U Operating mode changeover input for day night remote control Selectable installation and control parameters Adjustable minimum limitation for cooling output RDU50U Optional selectable Direct Acting or Reverse Acting output RDU50U and RDU50 2U Selectable display of room temperature or setpoint Fahrenheit or Celsius selectable display Minimum and ma...

Страница 24: ... Mode Cooling 75 to 95 F 24 to 35 C Operation Temperature 32 to 122 F 0 to 50 C Humidity 95 RH Shipping and Storage Temperature RDU50U and RDU50 2U 13 to 158 F 25 to 70 C RDU20U 13 to 140 F 25 to 60 C Humidity 95 RH Agency Approvals Conforms to CE Requirements NEMA 1 Connection Terminals Use Solid Wires or Prepared Stranded Wires 2 x 16 AWG or 1 x 14 AWG Maximum 20 AWG Housing Color Cover White Ba...

Страница 25: ...vaccomponents Thermostats A 61 RDU Controller Dimensions shown in inches mm TH0769R1 4 61 117 3 78 96 1 38 35 Baseplate TH0772R1 4 21 107 1 77 45 1 18 30 0 16 4 0 98 25 3 54 90 1 10 28 1 10 28 0 1 6 4 1 10 28 1 10 28 0 28 7 0 46 11 8 ...

Страница 26: ...Thermostats www usa siemens com hvaccomponents A 62 TECH TIPS Visit us on the web at www usa siemens com hvaccomponents for printable product specification sheets on all products in this catalog ...

Страница 27: ...r Operating modes Normal heating cooling Energy Saving Off Operating mode changeover input for remote control Selectable installation and control parameters Operating voltage 24 Vac Applications The RDX Series of Room Temperature Controllers are used for control of the following Heat pump systems with reversing valve optional electric heater one or two stage heating and one stage cooling Four pipe...

Страница 28: ...rential WD Adjustable 1 to 9 F 3 5 F 2 K Setpoint Energy Saving Mode Heating 46 to 64 F 61 F 16 C Setpoint Energy Saving Mode Cooling 75 to 95 F 82 5 F 28 C Operation Temperature 32 to 122 F 0 to 50 C Humidity 95 RH Shipping and Storage Temperature 13 to 158 F 25 to 70 C Humidity 95 RH Agency Approvals Conforms to CE Requirements NEMA 1 Connection Terminals Use Solid Wires or Prepared Stranded Wir...

Страница 29: ...vaccomponents Thermostats A 65 TH0870R1 4 33 117 3 78 96 1 38 35 RDX Controller Dimensions shown in inches mm Baseplate TH0772R1 4 21 107 1 77 45 1 18 30 0 16 4 0 98 25 3 54 90 1 10 28 1 10 28 0 1 6 4 1 10 28 1 10 28 0 28 7 0 46 11 8 ...

Страница 30: ...nents A 66 TECH TIPS Visit us on the web at www usa siemens com hvaccomponents You can search for products by part number or description print out product information for submittals link to technical documentation locate a distributor near you ...

Страница 31: ...g voltage 24 Vac Applications Typical use for RDF10U Control of the room temperature in individual rooms that are heated or cooled with two pipe fan coil units Opening or closing a valve and switching a three speed fan Typical use for RDF20U Control of the room temperature in individual rooms that are heated or cooled with two pipe fan coil units equipped with an electric heater Opening or closing...

Страница 32: ... at 77 F 25 C 1 F 0 5 K maximum Switching Differential In Heating Mode Adjustable 2 K 3 6 F Switching Differential In Cooling Mode Adjustable 1 K 1 8 F Setpoint Economy Mode Heating Adjustable 61 F 16 C Setpoint Economy Mode Cooling Adjustable 82 F 28 C Setpoint Standby Heating Adjustable 46 F 8 C Setpoint Standby Cooling Adjustable OFF Operation Temperature 32 to 122 F 0 to 50 C Humidity 95 RH Tr...

Страница 33: ...ts Thermostats A 69 TH0870R1 4 33 117 3 78 96 1 38 35 RDF Controller Dimensions shown in inches mm Baseplate TH0772R1 4 21 107 1 77 45 1 18 30 0 16 4 0 98 25 3 54 90 1 10 28 1 10 28 0 1 6 4 1 10 28 1 10 28 0 28 7 0 46 11 8 Dimensions ...

Страница 34: ...vaccomponents A 70 TECH TIPS Check your order status quickly and easily via our secure Order Tracker feature To take advantage of time saving benefits go online to www usa siemens com hvaccomponents click on site360 and register today ...

Страница 35: ...ts Applications 141 Surface Mounted Thermostat The 141 Surface Mounted Thermostat is ideal as a low or high limit control on unit heaters Also can be used as a convector or fan coil changeover control for automatically selecting the heating or cooling function based on water temperature 141 Electric High Temperature Thermostat The 141 Electric High Temperature Thermostat is nor mally located in a ...

Страница 36: ...ions 2 30 W x 5 38 H x 1 84 D 58 mm W x 173 mm H x 47 mm D Shipping Weight 2 0 lb 0 9 kg Part No 141 0530 Setpoint Range 25 to 215 F 4 to 102 C Switch Action SPST open on rise Factory Temperature Setting 125 F 52 C Electrical Ratings Motor Rating 10 FLA 120 Vac 6 FLA 240 Vac Noninductive Rating 1 A 0 3 to 12 Vac 6 A 12 50 Vac Agency Approvals UL MP3487 CSA LR6246 Cover Finish Gray Baked Enamel Dim...

Страница 37: ...t stops with a fixed differential Available with manual or automatic reset Electroplated copper capillary tube for sensitivity and durability Switches 120 V or 20 Vac Universal mounting bracket included Applications The 134 Electric Low Temperature Detection Thermostats are ideally suited for detecting potential freeze up conditions of heating coils cooling coils liquid heating pipes and similar a...

Страница 38: ... x 3 19 H x 2 31 D 59 mm W x 81 mm H x 59 mm D Shipping Weight 1 8 lb 0 8 kg Part No 134 1511 Dimensions 2 31 W x 3 19 H x 2 31 D 59 mm W x 81 mm H x 59 mm D Shipping Weight 1 8 lb 0 8 kg 134 A 91 Accessories Service Kits Switch Reset Temperature Range Action Bulb Size Action Part No 35 to 45 F 1 7 to 7 2 C SPDT 1 8 x 20 3 mm x 6 m Automatic 134 1510 35 to 45 F 1 7 to 7 2 C SPDT 1 8 x 20 3 mm x 6 ...