Pointek CLS500 – INSTRUCTION MANUAL
7ML19985GG03
Rotary Switch Positions – Quick Reference (FSH Mode)
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Menu LEVEL 0 (00 to OF) MSP2002-1 Transmitter in F(ail) S(afe) H(igh) or F(ail) S(afe) L(ow) mode
Units
PV Units
Num.
Selection
PV Units
Seconds
Seconds
%
%
mA
mA
Numeri-
cal
Numeri-
cal
PV Units
PV Units
PV Units
PV Units
PV Units
NO KEYS
Value
read-out
PV Value
or
Fault
Show
select PV
variable
Highest/
Lowest
PV
Memory
Activation
Time Delay
Current sig-
nal
De-Activation
Time Delay
Current signal
Upper Thresh-
old
Activation
Current signal
Lower Thresh-
old
De-Activation
Current signal
Loop Current
in mA
Failsafe
Mode
Actual
Step
Size
Damping
Value
LOWER limit
PV
UPPER limit
PV
Delta Value
PV
for 4 or 20
mA
LRV Value
PV
for 4 mA
URV Value
PV
for 20 mA
Up
KeyRED
(+)
Set
Menu
Level
00 to 0F
Step TV0 to
TVmax
Highest
PV Memory
Read-out
Increase
Delay Time
Increase
Delay Time
Increase
Upper
Threshold
Point
Increase
Lower
Threshold
Point
Loop Current
in mA
F(ail)
S(afe)
H(igh)
Increase
Step Size
to 10000
Increase
Damping
Value
Increase
PV
LOWER limit
Increase
PV
UPPER limit
Increase
PV
Delta
Increase
PV
LRV
Increase
PV
URV
Down
Key-
BLUE (–)
Set
Menu
Level
10 to 1F
Step TVmax
to TV0
Lowest
PV Memory
Read-out
Decrease
Delay Time
Decrease
Delay Time
Decrease
Upper Thresh-
old
Point
Decrease
Lower Thresh-
old Point
Loop Current
in mA
F(ail)
S(afe)
L(ow)
Decrease
Step Size
to 0.01
Decrease
Damping
Value
Decrease
PV
LOWER limit
Decrease
PV
UPPER limit
Decrease
PV
Delta
Decrease
PV
LRV
Decrease
PV
URV
Both
Keys
Show-
Menu
Level
Set
% Mode
Reset Hi/Lo
memories to
actual PV
Toggle
Delay Time
00 < – > 100
Toggle
Delay Time
00 < – > 100
Preset Upper
Threshold
Point to 75%
Preset Lower
Threshold
Point to 25%
Loop Current
in mA
Set to 1
Set to 1
Preset
Lower Limit to
Actual (PV)
Preset Upper
Limit to
Actual (PV)
URV– LRV
= Min.
LRV = Actual
Value (PV)
URV =
Actual
Value (PV)
*
TVO
*
00
00
75%
25%
FSH
FSH
1.0
1
1.0 pF
330 pF
330 pF
0 pF
330 pF
Menu LEVEL 1 (10 to 1F) MSP2002-1 Transmitter in F(ail) S(afe) H(igh) or F(ail) S(afe) L(ow) mode
Units
PV Units
Numerical
Factory
Settings
Seconds
Seconds
%
%
O/ C
O/C
nor / inv
Resp. Units
FSM
Keylock
NO KEYS
Value
read-out
PV Value
or
Fault
Display
check
Fault code
FAC
(factory set-
tings)
Activation
Time Delay
Transistor
Switch
De-Activation
Time Delay
Transistor
Switch)
Upper Thresh-
old Activation
Transistor
Switch
Lower Thresh-
old De-Activa-
tion Transistor
Switch
Status
Solid State
Output
Failsafe
Mode
MODE
Normal /
Inverse
—
Spare
—
Spare
Transmitter
Var 0
Read-Out
—
Spare
Show
Failsafe
Mode
Keylock
Level
Up
KeyRED
(+)
Set Menu
Level
00 to 0F
FAC
(factory set-
tings)
Increase
Delay Time
Increase
Delay Time
Increase
Upper Thresh-
old Point
Increase
Lower Thresh-
old Point
Status
Solid State
Output
F(ail)
S(afe)
H(igh)
MODE
Normal /
Inverse
Transmitter
Var 1
Read-Out
F(ail)
S(afe)
H(igh
Increase
Keylock
Level