Mounting
3-6
SIMATIC Panel PC 670 / 870 Operating Unit, Equipment Manual
Edition 07/02
3.2.2
Panel PC 870
The operating unit can be fitted in the mounting cut-out with either clamps
or screws.
S
Protection class IP 65 is possible when the operating unit is secured with
clamps (in conjunction with a continuous gasket).
S
Protection class IP 54 is achieved with screw fixings.
L1
L2
112
±
0.5
L4
L5
11
2
±
0.5
±
1
56
min. 1.5 – max. 6
L3
±
1
A1
±
1
A2
±
1
Clamp with grub screws
Drill hole for
±
0.2
±
0.2
+1
+1
Rz 120 (in gasket area)
Gasket area
M6/ 7
Pressure points
for clamps
screw fixings
L3
±
1
112
±
0.5
Operating units
L1 L2 L3 L4 L5 A1 A2
(a) with key-based front panels:
12.1” TFT
450 290
78 465 235 16
10
15.1” TFT (8 modules)
450 321
51 465 279 16
17
(b) with touchscreen front panel:
15.1” TFT
450 290 81 465 235 16
10
*)
*)
*)
cut-outs only for 15” TFT
(keyboard version),
(for dimensions, see Fig. 3-2)
Fig. 3-4
Dimensions for installation of the operating unit of Panel PC 870