Siemens NET-7 Скачать руководство пользователя страница 2

2

INSTALLATION

Remove all system power before installation,
first battery and then AC. 

(To power up, first

connect the AC and then the battery.)

All wiring must comply with national and
local codes.

1.

Remove the NET-7 from the antistatic bag.

CAUTION:

Do not touch the gold plated
card edge on the NET-7.

2.

Set the address for the NET-7 using switch S1.
Refer to Table 1 for the switch settings.  Be sure
that the address agrees with the CSG-M network
map.

3.

Determine whether the communication mode is
Style 4 or Style 7. Place the shorting jumper on
P3 to agree with the style selected. (See Figure 1
for the location of P3.)

NOTE:

On the MMB set jumper P15 to the S7
position regardless of the communication
mode (Style 4 or Style 7) selected on the
NET-7.

4.

Decide whether to install the NET-7 into a PSR-1
or into the enclosure with the MMB. If the
installation is in a PSR-1, skip to step 8.

5.

Install the NET-7 that is in the enclosure with the
MMB in a MOM-4 slot. Any available MOM-4 slot
can be used. Mount one of the two card guides
provided in the MOM-4. Slip the guide under the
mounting screw in the center of the MOM-4 and
tighten.

6.

Refer to Figure 2 for the wiring diagram. Check
all wiring prior to installing the NET-7 into the
MOM-4. Failure to properly wire the NET-7 can
cause damage to the board.

7.

Install the NET-7 into the MOM-4 slot. Be sure
that the board is firmly seated in the card edge
connector. This completes the installation of the
NET-7 with the MMB.

8.

When used with a PSR-1, install the NET-7 into
connector P7.

• If screws are in the location where the card

guide is to be installed, remove the screws
and mount the card guide with the hardware
supplied.

• Mount the two card guides supplied onto the

PSR-1 by loosening the screws above and
below P7. Then slide the guides under the
screws and tighten them.

9.

Refer to Figure 2 for the wiring diagram. Connect
the network wires to TB4 on the PSR-1 as shown.

10. Install the NET-7 into P7. Be sure that the board

is firmly seated.

11. If an MKB-2 is installed, the NET-7 must be

located in a MOM slot. In this configuration, the
setting in the CSG-M for the PSR-1 style type
should be

 none

 and a NET-7 should be installed

in the network map.

Note on End of Line Resistors

End of line resistors are provided with each NET-7.

DO NOT PLACE AN END OF LINE RESISTOR AT
EACH NET-7. 

These devices are required at the two

extreme ends of each network pair as shown in
Figure 2. It is not required that the MMB be at one of
the ends. It may be at any location along the net-
work. T-Tapping is not allowed on the network.

ELECTRICAL RATINGS

Figure 1   NET-7 Board

t

n

e

r

r

u

C

e

l

u

d

o

M

C

D

V

5

e

v

i

t

c

A

A

m

0

2

1

t

n

e

r

r

u

C

e

l

u

d

o

M

C

D

V

4

2

e

v

i

t

c

A

A

m

0

t

n

e

r

r

u

C

e

l

u

d

o

M

C

D

V

4

2

y

b

d

n

a

t

S

A

m

0

3

Содержание NET-7

Страница 1: ...to the modules in the enclosure In normal operation the SELECT LED turns on and off every time there is network activity If this LED remains in one state either on or off it indicates that one or both of the pairs is not functional The SELECT LED lights when the PRIMARY pair is selected The NET 7 can also provide a Style 4 communication mode In that configuration all NET 7s must be set to Style 4 ...

Страница 2: ...e to the board 7 Install the NET 7 into the MOM 4 slot Be sure that the board is firmly seated in the card edge connector This completes the installation of the NET 7 with the MMB 8 When used with a PSR 1 install the NET 7 into connector P7 If screws are in the location where the card guide is to be installed remove the screws and mount the card guide with the hardware supplied Mount the two card ...

Страница 3: ... INSTALLED IN MAIN ENCLOSURE WIRING MUST BE CONNECTED AT THE NET 7 ONLY SET JUMPER P7 TO POSITION 2 3 SEE MMB 3 INSTALLATION INSTRUCTIONS P N 315 048860 CSG M CONFIGURATION MUST BE LOADED VIA NET 7 PROGRAMMING PORT P1 MAKE SURE THE CSG M SETTING LOCAL NETWORK COMM STYLE IS SET TO STYLE 7 AND MMB 3 MNET STYLE 7 IS SET TO NO 6 REFER TO WIRING SPECIFICATION FOR MXL MXL IQ AND MXLV SYSTEMS P N 315 091...

Страница 4: ...OXXO OXXXOXXX 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 XOOOOOXX XOOOOXOO XOOOOXOX XOOOOXXO XOOOOXXX XOOOXOOO XOOOXOOX XOOOXOXO XOOOXOXX XOOOXXOO XOOOXXOX XOOOXXXO XOOOXXXX XOOXOOOO XOOXOOOX XOOXOOXO XOOXOOXX XOOXOXOO XOOXOXOX XOO...

Отзывы: