Faults, causes and remedies
BA 2515
Operating Instructions, 10/2016, A5E38123453A/RS-AB
39
Faults
Causes
Remedy
Oil leak at the
gearbox vent.
Incorrect oil level for the mounting
position used and / or incorrect
venting position.
Check the venting position, the
mounting position (Page 63) and the oil
Frequent cold starts during which the
oil foams up.
Call Technical Support.
Gearbox overheats. Motor fan cover and / or gearbox
very dirty.
Clean the fan cover and surface of the
geared motor (Page 55).
Incorrect oil level for the mounting
position being used.
Check the mounting position (Page 63)
and the oil level (Page 43).
Incorrect oil being used (e.g.
incorrect viscosity).
Checking the oil quality (Page 45).
Oil is too old.
Check the date of last oil change. If
required, change the oil (Page 43).
Excessive bearing play and / or
bearing defective.
Check the bearing and replace if
necessary.
Backstop not running freely.
Replace the backstop.
Output shaft does
not turn when the
motor is running.
Force flow interrupted by breakage in
gearbox.
Call Technical Support.
Содержание MOTOX BA 2515
Страница 1: ......
Страница 2: ......
Страница 8: ...Table of contents BA 2515 8 Operating Instructions 10 2016 A5E38123453A RS AB ...
Страница 58: ...Disposal BA 2515 58 Operating Instructions 10 2016 A5E38123453A RS AB ...
Страница 75: ...Spare parts 11 2 Spare parts lists BA 2515 Operating Instructions 10 2016 A5E38123453A RS AB 75 ...
Страница 78: ...Declaration of Incorporation BA 2515 78 Operating Instructions 10 2016 A5E38123453A RS AB ...
Страница 79: ......
Страница 80: ......