PROFIBUS Optional Board Operating instructions
56
6SE6400-5AK00-0BP0
Parameter accessing error (r2054.04), error numbers < 240 correspond to PKW
error numbers:
Table 7-5
1R
&DXVH
5HPHG\HJLQ3UR7RRO
No. 0 .. 199: Parameter access has been converted to a PKW request. Error detected in converter.
Additional info in r2054.05, r2054.06: Parameter number, index word
0
Parameter number does not exist
Check data block number
1
Parameter value cannot be modified
-
2
Minimum/maximum not reached or
exceeded
-
3
Subindex does not exist
Check data block offset
4
Access to single value with array identifier
Set data block offset = 0
5
Access to word with double word request or
vice versa
Use correct data type
(e.g. INT for word, DINT for double word)
6
Setting not allowed (resetting only)
-
7
Descriptive element cannot be modified
-
11
No status as master control
-
12
Key word missing
-
17
Request cannot be processed due to
operating state
-
101
Parameter number currently deactivated
-
102
Channel not wide enough
-
104
Illegal parameter value
-
106
Request not implemented
-
200/
201
Modified minimum/maximum not
reached/exceeded
Minimum/maximum can be further limited in
operation
No. 240-249: Parameter access is incorrectly formatted. Error detected on the PROFIBUS-DP
communication board.
Additional info in r2054.05, r2054.06: Parameter number or S7 data block number, subindex or S7
data block offset.
240
Error in variable address (no additional info)
Legal: "Data block" area
241
Data block number illegally formatted
Legal: 1...31999
242
Data block offset illegally formatted
Legal: 0...116
243
Illegal "type"
Legal: CHAR. BYTE, INT, WORD, DINT,
DWORD, REAL
244
Illegal "Number of elements" on accessing
parameter value
Legal: Effectively 2 or 4 bytes
248
Illegal text/description modification
-
249
Inconsistency in write request: "Type" and
"Number of elements" does not match "Data
type" and "Data length"
(error in communication partner)
No. 250: Parameter access has been converted to a PKW request. Response from converter is
errored. Error detected on the PROFIBUS-DP communication board. Additional info in r2054.05,
r2054.06: Parameter number, subindex.
250
PKW response does not match request
(error in converter)
No. 251: Error detected on the PROFIBUS-DP communication board; no additional info
251
Response too long for response telegram
(error in communication partner)
Содержание Micromaster Profibus
Страница 1: ...0 520 67 5 352 86 2SWLRQDO RDUG 2SHUDWLQJ LQVWUXFWLRQV GLWLRQ 8VHU RFXPHQWDWLRQ ...
Страница 2: ......
Страница 8: ... GLWLRQ PROFIBUS Optional Board Operating instructions 8 6SE6400 5AK00 0BP0 ...
Страница 10: ... GLWLRQ PROFIBUS Optional Board Operating instructions 10 6SE6400 5AK00 0BP0 ...
Страница 16: ... HQHUDO HILQLWLRQ RI 352 86 3 GLWLRQ PROFIBUS Optional Board Operating instructions 16 6SE6400 5AK00 0BP0 ...
Страница 52: ... LQNV WR 352 86 3 0DVWHU 6 VWHPV GLWLRQ PROFIBUS Optional Board Operating instructions 52 6SE6400 5AK00 0BP0 ...
Страница 58: ... LDJQRVWLFV DQG 7URXEOHVKRRWLQJ GLWLRQ PROFIBUS Optional Board Operating instructions 58 6SE6400 5AK00 0BP0 ...
Страница 60: ... SSHQGL GLWLRQ PROFIBUS Optional Board Operating instructions 60 6SE6400 5AK00 0BP0 ...
Страница 62: ... ORVVDU GLWLRQ PROFIBUS Optional Board Operating instructions 62 6SE6400 5AK00 0BP0 ...
Страница 64: ......
Страница 65: ......