background image

 Environmental protection  

en

5

7

Environmental protection

Environmen

tal prote

ction

Your new appliance is particularly energy-efficient. Here 

you can find tips on how to save even more energy 

when using the appliance, and how to dispose of your 

appliance properly.

Saving energy

During cooking, ensure that there is a sufficient 

supply of air so that the extractor hood can work 

efficiently and with a low level of operating noise.

Adjust the fan speed to the intensity of the cooking 

fumes. Only use intensive mode where this is 

required. A lower fan speed means that less energy 

is consumed.

If there are intensive cooking fumes, select a higher 

fan speed in good time. If cooking fumes have 

already spread in the kitchen, the extractor hood 

must be operated for longer.

Switch off the extractor hood if you no longer require 

it.

Switch off the lighting if you no longer require it.

Clean and, if required, replace the filter at regular 

intervals in order to increase the effectiveness of the 

ventilation system and to prevent the risk of fire.

Environmentally-friendly disposal

Dispose of packaging in an environmentally-friendly 

manner.

Ç

Operating modes

Operating

 modes

Exhaust air mode

Note: 

The exhaust air must not be conveyed into a 

functioning smoke or exhaust gas flue or into a shaft 

which is used to ventilate installation rooms which 

contain heat-producing appliances.

Before conveying the exhaust air into a non-

functioning smoke or exhaust gas flue, obtain the 

consent of the heating engineer responsible.

If the exhaust air is conveyed through the outer wall, 

a telescopic wall box should be used.

Air recirculation

Note: 

To bind odours in air recirculation mode, you 

must install an activated carbon filter. The different 

options for operating the appliance in air recirculation 

mode can be found in the brochure. Alternatively, ask 

your dealer. The required accessories are available 

from specialist retailers, from customer service or from 

the Online Shop.

This appliance is labelled in accordance with 

European Directive 2012/19/EU concerning 

used electrical and electronic appliances 

(waste electrical and electronic equipment - 

WEEE). The guideline determines the 

framework for the return and recycling of used 

appliances as applicable throughout the EU.

The air which is drawn in is cleaned 

by the grease filters and conveyed to 

the exterior by a pipe system.

The air which is drawn in is cleaned by 

the grease filters and an activated 

carbon filter, and is conveyed back into 

the kitchen.

Содержание LI94MA530B

Страница 1: ...Register your product online siemens home com welcome HQ QVWUXFWLRQV IRU LQVWDOODWLRQ DQG XVH Extractor hood ...

Страница 2: ...location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance may be use...

Страница 3: ...coming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Grease deposits in the grease f...

Страница 4: ...bles replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Causes of damage Caution Risk of damage due to corrosion Always switch on t...

Страница 5: ...des Operatingmodes Exhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible If the exhaust air is conveyed through...

Страница 6: ... button to change the fan strength Switching off Press the button Slide the filter pull out in Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Press the button until all of the LEDs in the display light up The intensive setting is activated After approx six minutes the electronics automatically reduce the fan to a lower setting If you wa...

Страница 7: ...tal mesh grease filters also clean the holder for the metal mesh grease filters in the appliance using a damp cloth The metal mesh grease filters can be cleaned in the dishwasher or by hand By hand Note You can use a special grease solvent for stubborn dirt It can be ordered via the Online Shop Soak the metal mesh grease filters in a hot soapy solution Clean the filters with a brush and then rinse...

Страница 8: ...les replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Malfunction table Replacing bulbs These instructions apply to several appliance variants It is possible that individual features are described which do not apply to your appliance Warning Risk ...

Страница 9: ...Please be aware that a visit by an after sales engineer will be charged if a problem turns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed customer service list To book an engineer visit and product advice Rely on the professionalism of the manufacturer You can therefore be sure that the repair is carried out by t...

Страница 10: ...dividual features are described which do not apply to your appliance This appliance is installed in a upper cabinet Follow the enclosed installation instructions for additional special accessories e g for circulating air mode The surfaces of the appliance are sensitive Avoid damaging them during installation Appliance width 60 cm Appliance width 90 cm ...

Страница 11: ...ependent heat producing appliance is being operated Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system e g a chimney In combination with an activated vapour extractor hood room ai...

Страница 12: ... an electrician may install the fixed connection We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit Warning Danger of suffocation Packaging material is dangerous to children Never allow children to play with packaging material KGeneral information Generalinformation Exhaust air mode Warning Risk of death Risk of poisoning from flue gases that ar...

Страница 13: ...a residual current circuit breaker RCCB in the appliance s power supply circuit Preparing the units The fitted unit must be level and have sufficient load bearing capacity The max weight of the extractor hood is 18 kg Appliance dimensions and safety clearances Observe the appliance s dimensions Comply with the safety clearances If the installation instructions for the gas cooking appliances specif...

Страница 14: ...e the handle strip to the filter pull out 2 Connect the power cord provided to the appliance 3 Use the strain relief to secure the power cord in place 4 Screw the four angle brackets to the appliance Ensure that the screws are positioned correctly ª Screw in the screws until 8 mm of the threaded section is still protruding 5Installation Installation Installation 1 Use the angle brackets to hang th...

Страница 15: ...ales service Appliance width 90 cm You must also screw the appliance onto the side upper cabinets Change the filter pull out s limit stop On some versions of the appliance the limit stop for the filter pull out can be changed Spacers are included with these appliances in order to set the appliance s handle strip so that it is flush with the fitted unit 1 Pull the filter pull out forwards 2 Shorten...

Страница 16: ...BSH Hausgeräte GmbH Carl Wery Straße 34 81739 München GERMANY 9001057428 9001057428 960311 www siemens home com 0DQXIDFWXUHG E 6 DXVJHUlWH PE XQGHU 7UDGHPDUN LFHQVH RI 6LHPHQV ...

Отзывы: