  Important safety information   

en

3

(

Important safety 

information

Important

 safety i

nformatio

n

:

Warning

Danger of suffocation!

Packaging material is dangerous to children. 

Never allow children to play with packaging 

material.

:

Warning

Danger of death!

Risk of poisoning from flue gases that are 

drawn back in.

Always ensure adequate fresh air in the room 

if the appliance is being operated in exhaust 

air mode at the same time as room air-

dependent heat-producing appliance is being 

operated.

Room air-dependent heat-producing 

appliances (e.g. gas, oil, wood or coal-

operated heaters, continuous flow heaters or 

water heaters) obtain combustion air from the 

room in which they are installed and discharge 

the exhaust gases into the open air through an 

exhaust gas system (e.g. a chimney).

In combination with an activated vapour 

extractor hood, room air is extracted from the 

kitchen and neighbouring rooms - a partial 

vacuum is produced if not enough fresh air is 

supplied. Toxic gases from the chimney or the 

extraction shaft are sucked back into the living 

space.

Adequate incoming air must therefore 

always be ensured.

An incoming/exhaust air wall box alone will 

not ensure compliance with the limit.

Safe operation is possible only when the 

partial vacuum in the place where the heat-

producing appliance is installed does not 

exceed 4 Pa (0.04 mbar). This can be 

achieved when the air needed for combustion 

is able to enter through openings that cannot 

be sealed, for example in doors, windows, 

incoming/exhaust air wall boxes or by other 

technical means.

In any case, consult your responsible Master 

Chimney Sweep. He is able to assess the 

house's entire ventilation setup and will 

suggest the suitable ventilation measures to 

you.

Unrestricted operation is possible if the vapour 

extractor hood is operated exclusively in the 

circulating-air mode.

:

Warning

Risk of fire!

Grease deposits in the grease filter may 

catch fire.

Clean the grease filter at least every 

2 months. 

Never operate the appliance without the 

grease filter.

Risk of fire!

Grease deposits in the grease filter may 

catch fire. Never work with naked flames 

close to the appliance (e.g. flambéing). Do 

not install the appliance near a heat-

producing appliance for solid fuel (e.g. 

wood or coal) unless a closed, non-

removable cover is available. There must 

be no flying sparks.

Risk of fire!

Hot oil and fat can ignite very quickly. Never 

leave hot fat or oil unattended. Never use 

water to put out burning oil or fat. Switch off 

the hotplate. Extinguish flames carefully 

using a lid, fire blanket or something similar. 

Risk of fire!

When gas burners are in operation without 

any cookware placed on them, they can 

build up a lot of heat. A ventilation 

appliance installed above the cooker may 

become damaged or catch fire. Only 

operate the gas burners with cookware on 

them.

Risk of fire!

Operating several gas burners at the same 

time gives rise to a great deal of heat. A 

ventilation appliance installed above the 

cooker may become damaged or catch fire. 

Never operate two gas burners 

simultaneously on the highest flame for 

longer than 15 minutes. One large burner of 

more than 5 kW (wok) is equivalent to the 

power of two gas burners.

Содержание LI94MA530B

Страница 1: ...Register your product online siemens home com welcome HQ QVWUXFWLRQV IRU LQVWDOODWLRQ DQG XVH Extractor hood ...

Страница 2: ...location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance may be use...

Страница 3: ...coming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Grease deposits in the grease f...

Страница 4: ...bles replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Causes of damage Caution Risk of damage due to corrosion Always switch on t...

Страница 5: ...des Operatingmodes Exhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible If the exhaust air is conveyed through...

Страница 6: ... button to change the fan strength Switching off Press the button Slide the filter pull out in Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours Press the button until all of the LEDs in the display light up The intensive setting is activated After approx six minutes the electronics automatically reduce the fan to a lower setting If you wa...

Страница 7: ...tal mesh grease filters also clean the holder for the metal mesh grease filters in the appliance using a damp cloth The metal mesh grease filters can be cleaned in the dishwasher or by hand By hand Note You can use a special grease solvent for stubborn dirt It can be ordered via the Online Shop Soak the metal mesh grease filters in a hot soapy solution Clean the filters with a brush and then rinse...

Страница 8: ...les replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Malfunction table Replacing bulbs These instructions apply to several appliance variants It is possible that individual features are described which do not apply to your appliance Warning Risk ...

Страница 9: ...Please be aware that a visit by an after sales engineer will be charged if a problem turns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed customer service list To book an engineer visit and product advice Rely on the professionalism of the manufacturer You can therefore be sure that the repair is carried out by t...

Страница 10: ...dividual features are described which do not apply to your appliance This appliance is installed in a upper cabinet Follow the enclosed installation instructions for additional special accessories e g for circulating air mode The surfaces of the appliance are sensitive Avoid damaging them during installation Appliance width 60 cm Appliance width 90 cm ...

Страница 11: ...ependent heat producing appliance is being operated Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heaters or water heaters obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open air through an exhaust gas system e g a chimney In combination with an activated vapour extractor hood room ai...

Страница 12: ... an electrician may install the fixed connection We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit Warning Danger of suffocation Packaging material is dangerous to children Never allow children to play with packaging material KGeneral information Generalinformation Exhaust air mode Warning Risk of death Risk of poisoning from flue gases that ar...

Страница 13: ...a residual current circuit breaker RCCB in the appliance s power supply circuit Preparing the units The fitted unit must be level and have sufficient load bearing capacity The max weight of the extractor hood is 18 kg Appliance dimensions and safety clearances Observe the appliance s dimensions Comply with the safety clearances If the installation instructions for the gas cooking appliances specif...

Страница 14: ...e the handle strip to the filter pull out 2 Connect the power cord provided to the appliance 3 Use the strain relief to secure the power cord in place 4 Screw the four angle brackets to the appliance Ensure that the screws are positioned correctly ª Screw in the screws until 8 mm of the threaded section is still protruding 5Installation Installation Installation 1 Use the angle brackets to hang th...

Страница 15: ...ales service Appliance width 90 cm You must also screw the appliance onto the side upper cabinets Change the filter pull out s limit stop On some versions of the appliance the limit stop for the filter pull out can be changed Spacers are included with these appliances in order to set the appliance s handle strip so that it is flush with the fitted unit 1 Pull the filter pull out forwards 2 Shorten...

Страница 16: ...BSH Hausgeräte GmbH Carl Wery Straße 34 81739 München GERMANY 9001057428 9001057428 960311 www siemens home com 0DQXIDFWXUHG E 6 DXVJHUlWH PE XQGHU 7UDGHPDUN LFHQVH RI 6LHPHQV ...