Siemens LI60LBC24 Скачать руководство пользователя страница 12

en 

Installation instructions

12

11.7 Instructions for the electrical
connection

In order to safely connect the appliance to the elec-
trical system, follow these instructions.

WARNING ‒ Risk of electric shock!

It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed.

The mains plug for the mains power cable must be
easily accessible after the appliance is installed.

If this is not possible, an all-pole isolating switch
must be integrated into the permanent electrical in-
stallation according to the conditions of overvoltage
category III and according to the installation regula-
tions.

The permanent electrical installation must only be
wired by a professional electrician. We recommend
installing a residual-current circuit breaker (RCCB)
in the appliance's power supply circuit.

Sharp-edged components inside the appliance may
damage the connecting cable.

Do not kink or trap the connecting cable.

¡

The connection data can be found on the rating
plate. → 

Page 8

¡

The connecting cable is approx. 1.30 m long.

¡

This appliance complies with the EC interference
suppression regulations.

¡

The appliance corresponds to protection class 1.
You should therefore only use the appliance with a
protective earth connection.

¡

Do not connect the appliance to the power supply
during installation.

¡

Ensure that the protection against contact is guaran-
teed during installation.

11.8 Instructions for the exhaust air pipe

The appliance manufacturer does not provide any war-
ranty for faults attributable to the pipeline.

¡

Use a short, straight exhaust air pipe with as large a
pipe diameter as possible.

¡

Long, rough exhaust air pipes, many pipe bends or
small pipe diameters reduce the suction power and
increase the fan noise.

¡

Use an exhaust pipe that is made of non-combust-
ible material.

¡

To prevent condensate from returning, fit the ex-
haust pipe with a 1° gradient from the appliance.

Round pipes

Use round pipes with an inner diameter of 150 mm (re-
commended) or at least 120 mm.

11.9 Instructions for the air extraction mode

For air extraction mode, a one-way flap should be in-
stalled.

Notes

¡

If a one-way flap is not included with the appliance,
one can be ordered from a specialist retailer.

¡

If the exhaust air is conveyed through the external
wall, a telescopic duct should be used.

11.10 Installation

Checking the unit

1.

Check whether the fitted unit is level and has suffi-
cient load-bearing capacity.
The max. weight of the appliance is 6 kg.

2.

Ensure that the fitted unit is heat-resistant up to
90 °C.

3.

Ensure that the fitted unit is still stable after the cut-
outs have been made.

Preparing the units

Requirement:

 The unit is suitable for the installation. 

→ 

"Checking the unit", Page 12

1.

Cover the hob to prevent damage.

2.

Ensure that the fitted unit is still stable after the cut-
outs have been made.

3.

Make the cut-out for the exhaust pipe.

4.

When installing in cabinets with an intermediate
floor, make the cut-out in the intermediate floor.

5.

Remove any shavings.

Preparing the appliance

Remove the grease filters.
To avoid causing damage, do not bend the grease
filters.

Installing the appliance

1.

When installing without an intermediate floor, meas-
ure and mark the holes for the mounting brackets
on the side walls.

102
83

2.

When installing with an intermediate floor, slightly
screw the mounting brackets onto the appliance. In-
sert the appliance into the opening in the intermedi-
ate floor. Mark the holes for the mounting brackets
on the side walls. Unscrew the mounting brackets
from the appliance again.

3.

Screw the mounting brackets to the unit. In doing
so, only tighten the screws tight enough that the
mounting bracket can still be moved.

Содержание LI60LBC24

Страница 1: ... LI60LBC24 en User manual and installation instructions Register your product on My Siemens and discover exclusive ser vices and offers siemens home bsh group com welcome The future moving in Siemens Home Appliances ...

Страница 2: ...on Only use this appliance For extracting cooking vapour In private households and in enclosed spaces in a domestic environment Up to an altitude of max 2000 m above sea level Do not use the appliance With an external timer 1 3 Restriction on user group This appliance may be used by children aged 8 or over and by people who have reduced physical sensory or mental abilities or inad equate experienc...

Страница 3: ...eration is possible if the ap pliance is operated exclusively in circulat ing air mode WARNING Risk of fire Fatty deposits in the grease filters may catch fire Never operate the appliance without a grease filter Clean the grease filters roughly every 2 months Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a solid fuel heating appliance e g wood ...

Страница 4: ...unction with aluminium parts in the interior of the appliance may cause ex plosions Never use highly caustic alkaline or highly acidic cleaning agents In particular do not use commercial or industrial cleaning agents in conjunction with aluminium parts e g grease filter on extractor hoods 2 Avoiding material damage ATTENTION Condensate may cause corrosion damage To prevent condensation from buildi...

Страница 5: ...es burning gas or other fuels not applicable to appliances that only discharge the air back into the room If the exhaust air is to be conveyed into a non functioning smoke or ex haust gas flue you must obtain the consent of the heating engineer re sponsible If the exhaust air is conveyed through the external wall a tele scopic duct should be used 5 Familiarising yourself with your appliance 5 1 Co...

Страница 6: ... or highly acidic cleaning agents In particular do not use commer cial or industrial cleaning agents in conjunction with aluminium parts e g grease filter on extractor hoods WARNING Risk of electric shock An ingress of moisture can cause an electric shock Before cleaning pull out the mains plug or switch off the fuse in the fuse box Do not use steam or high pressure cleaners to clean the appliance...

Страница 7: ...hen cleaning the grease filter in the dish washer light discolouration may occur This discoloura tion has no effect on the performance of the metal grease filters Requirement The grease filters have been removed Removing the grease filter Page 7 1 Observe the information regarding the cleaning agents 2 Place the grease filters loosely into the dishwasher Do not clean heavily soiled grease filters ...

Страница 8: ...s applicable throughout the EU 10 Customer Service If you have any queries on use are unable to rectify faults on the appliance yourself or if your appliance needs to be repaired contact Customer Service Function relevant genuine spare parts according to the corresponding Ecodesign Order can be obtained from Customer Service for a period of at least 10 years from the date on which your appliance w...

Страница 9: ...en installing the appliance 11 1 Scope of delivery After unpacking all parts check for any damage in transit and completeness of the delivery 11 2 Unit dimensions You will find the dimensions of the appliance here 11 3 Safety clearances Comply with the safety clearances for the appliance ...

Страница 10: ...es to you Unrestricted operation is possible if the ap pliance is operated exclusively in circulat ing air mode Risk of poisoning from flue gases being drawn back in If an extractor hood with an open flued heat production source is installed the power supply for the extractor hood must be provided with a suitable safety switch Risk of poisoning from flue gases being drawn back in Do not emit the e...

Страница 11: ...r supply with alternating current only via a properly installed socket with earthing The protective conductor system of the do mestic electrical installation must be prop erly installed Never equip the appliance with an external switching device e g a timer or remote control When the appliance is installed the mains plug of the power cord must be freely ac cessible If free access is not possible a...

Страница 12: ...rs reduce the suction power and increase the fan noise Use an exhaust pipe that is made of non combust ible material To prevent condensate from returning fit the ex haust pipe with a 1 gradient from the appliance Round pipes Use round pipes with an inner diameter of 150 mm re commended or at least 120 mm 11 9 Instructions for the air extraction mode For air extraction mode a one way flap should be...

Страница 13: ...ut the filter pull out fully 2 Undo the screw for the front end stop and pull it for wards as far as possible 3 Close the filter pull out and align it to the furniture 4 Pull out the filter pull out again 5 Retighten the screw for the front end stop Setting the air flow Requirement The grease filters have been removed Removing the grease filter Page 7 1 To set the air flow change the position of t...

Страница 14: ...ausing damage do not bend the grease filters 4 Loosen the screw connection with the fitted unit 5 Remove the appliance 11 11 Air flow diagrams You can find the air flow diagrams below Basic ventilation adjustment diagram Static pressure drop pA L The A measured sound pressure level at 10 m sabin L The A measured sound pressure level relative to 1 pW WA Setting Airflow ...

Страница 15: ...10 K11 K12 K factor 0 50 0 63 0 75 0 89 0 93 1 06 1 12 1 23 1 36 1 47 1 57 1 69 Basic ventilation size diagram Real pressure in the ventilation duct pA L The A measured sound pressure level at 10 m sabin L The A measured sound pressure level relative to 1 pW WA ...

Страница 16: ...am Static pressure drop pA L The A measured sound pressure level at 10 m sabin L The A measured sound pressure level relative to 1 pW WA Cut away rings Existing opening of the reducing disc Without reducing disc Airflow K1 K2 K3 K4 K5 K factor 2 41 2 82 3 24 3 76 4 31 ...

Страница 17: ...lation instructions en 17 Forced ventilation size diagram Real pressure in the ventilation duct pA L The A measured sound pressure level at 10 m sabin L The A measured sound pressure level relative to 1 pW WA ...

Страница 18: ......

Страница 19: ......

Страница 20: ... 9001578323 9001578323 011027 en Manufactured by BSH Hausgeräte GmbH under the trademark licence of Siemens AG ...

Отзывы: