  Operating the appliance   

en

7

powerBoost position

On some appliances, the glass front can be adjusted to 

an intermediate position (powerBoost position). The 

powerBoost position can be used for eliminating 

particularly strong cooking smells and large amounts of 

steam.
Take hold of the glass front in the centre and open it 

carefully.

Automatic mode

Switching on

Touch the 

#

 symbol.

The fan will start at setting 2.

Touch the 

!

 symbol.

The optimum fan setting is set automatically using 

an air quality sensor.

Switching off

Touch the 

!

 or 

#

 symbol to switch off automatic 

mode.
The fan will switch itself off automatically if the air quality 

sensor detects no further change in the air quality in the 

room.
Automatic mode can run for a maximum of four hours.

Sensor control

In automatic mode, an air quality sensor in the extractor 

hood detects the intensity of the cooking and roasting 

odours. Depending on the air quality sensor setting, the 

fan will switch itself to another fan setting automatically.
Possible sensor settings:
Default sensitivity setting:  

Lowest sensitivity setting:  

Highest sensitivity setting:  

If the sensor controller responds too strongly or not 

enough, it can be changed accordingly:

1.

Touch and hold the 

!

 symbol for one second 

when the fan is switched off. The setting will be 

displayed.

2.

Slide your finger across control panel III to change 

the sensor control setting.

3.

Take your finger off the 

!

 symbol.

Fan run-on time

Switching on

Note: 

If intensive mode has been activated, the run-on 

function will not be available.

Touch the 

A

 symbol until 

x

 lights up on the display 

panel.
The fan will run at fan setting 1.
After approximately 10 minutes, the fan will switch itself 

off automatically.

Switching off

Slide your finger to the right across control panel III until 

a fan setting lights up in the display. 
This immediately stops fan run-on.

Saturation display

If the metal grease filters or activated charcoal filter are/

is saturated, the corresponding symbols will flash once 

the appliance has been switched off:

Metal grease filter: 

!

Activated charcoal filter: 

"

Metal grease filter and activated charcoal filter: 

 

!

 

and 

"

If you have not yet done so, the metal grease filters 

should now be cleaned or the activated charcoal filter 

replaced. 

~

 "Cleaning and maintenance" on page 13

The saturation indicators can be reset while they are 

flashing. Slide your finger to the left across the control 

panel to do so.

Switching over the display for air recirculation mode

For air recirculation mode, the electronic controller must 

be switched over accordingly:

The extractor hood must be connected and switched 

off.

Touch and hold the 

#

 and 

!

 symbols at the 

same time until "2" lights up for air recirculation 

mode (filters that cannot be regenerated). 

Repeatedly touching and holding this button 

combination makes "3" light up for air recirculation 

mode (filters that can be regenerated).

Repeatedly pressing and holding this button 

combination switches the electronic controller back 

over to air extraction mode ("1" ).

Audible signal 

Switching on

Touch and hold the 

#

 and 

&

 symbols at the same time 

for approximately 3 seconds when the fan is switched 

off. An audible signal will sound as an 

acknowledgement.
When the signal tone is activated, 

 will be lit.

Switching off

Touch and hold the 

#

 and 

&

 symbols at the same time 

for approximately 3 seconds when the fan is switched 

off. An audible signal will sound as an 

acknowledgement.
When the signal tone is deactivated, 

 will be lit.

Содержание LC91KWW20B

Страница 1: ...Register your product online siemens home bsh group com welcome en QVWUXFWLRQV IRU LQVWDOODWLRQ DQG XVH Extractor hood ...

Страница 2: ...s perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea...

Страница 3: ...ndows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Fatty deposits in the g...

Страница 4: ...t the after sales service Risk of electric shock Incorrect repairs are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaner...

Страница 5: ...modes Operatingmodes Exhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible If the exhaust air is conveyed throu...

Страница 6: ...ter approx 6 minutes the extractor hood automatically switches back to fan setting 3 Switching off If you would like to stop intensive mode before the preset time expires slide your finger to the left across control panel III to select the fan setting you require Lighting The lighting can be switched on and off independently of the fan Touch the symbol Setting the brightness Press and hold the sym...

Страница 7: ...fter approximately 10 minutes the fan will switch itself off automatically Switching off Slide your finger to the right across control panel III until a fan setting lights up in the display This immediately stops fan run on Saturation display If the metal grease filters or activated charcoal filter are is saturated the corresponding symbols will flash once the appliance has been switched off Metal...

Страница 8: ...independently of the fan Touch the i symbol Setting the brightness Press and hold the i symbol until the required brightness is reached Setting the colour 1 Switch off the fan 2 Touch the i symbol 3 Touch the A or symbol until the colour you require is selected Boost function Switching on Touch the symbol Note After approximately 20 seconds the extractor hood automatically switches back to the fan...

Страница 9: ...l a fan setting lights up in the display This immediately stops fan run on Saturation display If the metal grease filters or activated charcoal filter are is saturated the corresponding symbols will flash once the appliance has been switched off Metal grease filter Activated charcoal filter Metal grease filter and activated charcoal filter and If you have not yet done so the metal grease filters s...

Страница 10: ...he hob Using the controls on the extractor hood always takes priority It is not possible to use the hood controls on the hob during this time Setting up a connection The hood must be switched off before you can connect the hob and extractor hood Connecting directly Make sure that the hob is switched on and is in search mode Refer to your hob s instruction manual for more information Notes If your ...

Страница 11: ... pressing the symbol To connect the extractor hood to your home network the hood and the light must be switched off 1 Press and hold the symbol until the D and Ù indicators start flashing 2 To start automatic login to your home network swipe right over settings area until D and flash 3 Press the WPS button on the router within the next 2 minutes If the extractor hood has successfully connected it ...

Страница 12: ...ally We recommend that you install security updates as soon as possible Resetting the connection You can reset the connections you have saved on your home network and on Home Connect at any time Press and hold the and symbols until an audible signal sounds About data protection When your appliance is connected for the first time to a WLAN network which is connected to the Internet your appliance t...

Страница 13: ...all purpose cleaning products Oven spray Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with the cleaning products Removing metal grease filter 1 Open the glass front fully 2 Open the lock and swing down the metal grease filter When you do this take hold of the metal grease filter from underneath with your other hand 3 Take the metal grease fil...

Страница 14: ... rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing detergents Do not clean heavily soiled metal grease filters together with cookware Pla...

Страница 15: ...ructions apply to several appliance models It may be the case that an optional accessory that is listed does not apply for your appliance Note Observe the installation instructions in the accessory Problem Possible cause Solution The appliance does not work The plug is not plugged in Connect the appliance to the electricity supply Power cut Check whether other kitchen appliances are working Faulty...

Страница 16: ...o be operated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation mode For additional optional accessories refer to the installation instructions provided The surfaces of the appliance are sensitive Avoid damaging them during installation PLQ PP PLQ PP PD PP PLQ PP P...

Страница 17: ...tion Damage to the appliance The surfaces of the appliance are sensitive Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers Warning Risk of fire Fatty deposits in the grease filter may catch fire...

Страница 18: ...ncoming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or...

Страница 19: ...ning Danger of suffocation Packaging material is dangerous to children Never allow children to play with packaging material KGeneral information Generalinformation Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for s...

Страница 20: ... hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor hood such that the lower edge of the glass screen is in line with the lower edges of the adjacent wall hung cabinets Make sure that the specified safety clearances from the hob are complied with 2 Place...

Страница 21: ...ng without a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in fully PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP ...

Страница 22: ...ints Attaching the flue duct If the extractor hood is to be operated in exhaust air mode a flue duct must be fitted The flue duct does not need to be fitted for air recirculation mode Warning Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance Warning Risk of electric shock Components inside the appliance may have sharp edges These may d...

Страница 23: ...6 ...

Страница 24: ...BSH Hausgeräte GmbH Carl Wery Straße 34 81739 München GERMANY 9001158981 9001158981 961001 siemens home bsh group com 0DQXIDFWXUHG E 6 DXVJHUlWH PE XQGHU 7UDGHPDUN LFHQVH RI 6LHPHQV ...

Отзывы: