background image

12

Installation

This extractor hood 

is intended to be

mounted onto the kitchen wall.

1.

Remove the grease filter
(refer to Operating Instructions).

2.

Draw a line on the wall from the ceiling
to the lower edge of the hood at the
centre of the location where the hood is
going to be mounted.

3.

Use the template to mark the points on
the wall where the screws will be 
mounted. In order to make it easier to
hook the hood onto the screws, draw
the outline of the area where the hood
will be attached.

Ensure that the minimum distance bet-

ween the hob and the extractor hood is
maintained – 

550 mm

for an electric hob

and 

650 mm 

for a gas hob. The bottom

edge of the template equates to the lower
edge of the extractor hood.

4.

Drill 4 x 

l

8 mm holes for the extractor

hood and 2 x 

l

8 mm holes for the

chimney panelling. Insert plugs into the
holes so that they are flush with the wall.

23

172

455

68

150

mind.550 Elektro
mind.650 Gas

216

7.

Attach the extractor hood. 
Adjust the height and align horizontally
with the adjusting screws.

The glass screen must not touch the

wall.

Note: 

Take into account any special

accessories that are going to be fitted.

5.

Attach the 2 enclosed spacers to the
fixing bracket for the flue duct panelling.

6.

Screw on the upper and the two lower
fixing brackets.

Содержание LC57 Series

Страница 1: ...Operatingand installationinstructions LC 57 LC 58 ...

Страница 2: ...2 mind 650 mind 550 Abb 1 ELECTRO Fig 1 GAZ ...

Страница 3: ... is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the combined ventilation system for the entire household must be taken into consideration This rule does not apply to the use of cooking appliances such as hobs and oven...

Страница 4: ... to ensure they do not play with the appliance If the connecting cable for this appliance is damaged the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user The appliance may be connected to the mains by a qualified technician only Dispose of packaging materials properly see Installation instructions This...

Страница 5: ... As the filter becomes more and more saturated with grease not only does the risk of it catching fire increase but the efficiency of the extractor hood can also be adversely affected Important By cleaning the metal grease filters at appropriate intervals the possibility of them catching fire as a result of a build up of heat such as occurs when deep fat frying or roasting is taking place is reduce...

Страница 6: ...aler see optional accessories Use original filters only By doing so you will obtain maximum performance from your extractor hood Disposing of the old activated carbon filter There are no pollutants in the activated carbon filters They can therefore be disposed of as part of your normal domestic refuse 2 Clean the filters 3 Insert the clean filters back into the hood Activated carbon filter For neu...

Страница 7: ...faces Use a mild non abrasive stainless steel cleaner Clean the surface in the same direction as it has been ground and polished Do not use any of the following to clean stainless steel surfaces abrasive sponges cleaning agents containing sand soda acid or chloride Aluminium and plastic surfaces Use a soft non linting window cloth or micro fibre cloth Do not use dry cloths Use a mild window cleani...

Страница 8: ...liance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment by disposing of packaging materials in an environmentally friendly manner Please ask your dealer or inquire at your local authority about current means of disposal The extractor hood can be used in ex...

Страница 9: ...by the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if combustion air can flow through non lockable openings e g in doors windows and via the air intake exhaust air wall box or by other technical measures such as reciprocal interlocking etc If the air intake is inadequa...

Страница 10: ... be no sharp bends l 120 mm approx 113 cm2 l 150 mm approx 177 cm2 If pipes have different diameters Insert sealing strip For exhaust air mode ensure that there is an adequate supply of fresh air Circulating air mode With activated carbon filter if exhaust air mode is not possible Connecting a l 150 mm exhaust air pipe Mount the pipe directly onto the air outlet on the hood Connecting a l 120 mm e...

Страница 11: ...eakers and contactors If the connecting cable for this appliance is damaged the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user This extractor hood corresponds to EC regulations concerning RF interference suppression Electrical connection WARNING THIS APPLIANCE MUST BE EARTHED IMPORTANT Fitting a Diff...

Страница 12: ...e hob and the extractor hood is maintained 550 mm for an electric hob and 650 mm for a gas hob The bottom edge of the template equates to the lower edge of the extractor hood 4 Drill 4 x l 8 mm holes for the extractor hood and 2 x l 8 mm holes for the chimney panelling Insert plugs into the holes so that they are flush with the wall 23 172 455 68 150 mind 550 Elektro mind 650 Gas 216 7 Attach the ...

Страница 13: ...10 Connect the hood to the electricity supply 11 Remove the protective film from the two flue ducts Take care not to damage the stainless steel surfaces which are susceptible to scratches etc 12 Insert the upper flue duct slots downwards into the lower flue duct Protect the cover panels from scratches for example by laying the template used for marking the wall over the top edge of the lower secti...

Страница 14: ...14 Notes ...

Страница 15: ...15 360732 LZ 51850 1 2 3 4 5 6 2x 10x 2x ...

Страница 16: ...5750 208 045 Printed in Germany 0205 Es Siemens Electrogeräte GmbH ...

Отзывы: