13
If you need to connect the exhausted pipe to the
common chimney duct, DO NOT deeply insert the
exhausted pipe into the common chimney duct in
case the resistance increased when exhausting.
If you need to connect the exhausted pipe directly
outside the wall, a shutter (purchase additionally) is
recommended to be mounted at one end of the
exhausted pipe to prevent the external wind from
flowing back inside. Meanwhile, make sure the
exhausted pipe extending outside the wall is at least
30 mm.
The exhausted gas must not enter other hot flue
pipes, also for exhausting smoke of other fuels.
Fix the decorative cover and the adjustable cover on
the cooker hood according to the figure.
Insert the decorative cover into the cooker hood
vertically.
Draw out the adjustable cover from the decorative
cover, and fix it with the fixing brackets via screws.
Install the oil collector into the slot of the grease filter
frame according to the figure.
Installation Instruction
Connection of
Adjustable Cover
Installation of Oil Collector
5.
6.
7.
1.
2.
Connect to a common chimney duct Connect outside the wall
Minimum 30 mm
Ø175mm
Oil Collector