Correct flame formation

Burner

The flame formation and temperature development must be 

checked for each burner after the appliance is converted to a 

different gas type.
In the event of a problem, compare the nozzle values to the 

values in the table.

Only for models without safety pilot

1.

Ignite the hob burner as described in the operating 

instructions.

2.

Check the large and small flames for the correct flame 

formation. The flame must burn evenly and continuously.

3.

Using the burner knob, switch quickly between the large and 

small frame. Repeat this process a few times. The gas flame 

must not flicker or go out.

Only for models with safety pilot

1.

Ignite the hob burner as described in the operating 

instructions.

2.

Turn the burner knob to the small flame setting.  

Check whether the ignition is activated by holding the knob in 

the "small flame" position  for approximately 1 minute.

3.

Check the large and small flames for the correct flame 

formation. The flame must burn evenly and continuously.

4.

Using the burner knob, switch quickly between the large and 

small frame. Repeat this process a few times. The gas flame 

must not flicker or go out.

Oven

Lower gas burner or grill burner (optional)

1.

Ignite the lower gas burner as described in the operating 

instructions.

2.

Check the flame formation with the oven door open: 

The flame must burn evenly throughout (it may be slightly 

uneven in the first few minutes, but after a few minutes, the 

flames should burn constantly).

3.

To check that the thermocouple is functioning correctly, let 

the appliance run for a few minutes.
If necessary, check the settings. If it is not functioning 

correctly, replace the bypass screw in the burner.

Technical data – Gas

Different types of gas and the corresponding values are listed 

here.

Nozzle values for the auxiliary burner

Nozzle values for the standard burner

*G20/G25

G20

G20

G25

G25

G30/G31

**G30 G25.1 G27

G30

Gas pressure (mbar)

20/25

20

25

20

25

28-30/37

50

25

20

37

Nozzle (mm)

0.72

0.72

0.68

0.77

0.72

0.50

0.43

0.72

0.77

0.47

Bypass nozzle (mm)

0.50

0.50

0.50

0.50

0.50

0.30

0.30

0.50

0.50

0.30

Max. input power (kW)

1

1

1

1

1

1

1

1

1

1

Min. input power (kW)

 0.55

 0.55

 0.55

 0.55

 0.55

 0.55

 0.55

 0.55

 0.55

 0.55

Gas flow at 15 °C and 1013 mbar m³/h 0.095/

0.111

0.095

0.095

0.111 0.111 -

-

0.111 0.116 -

Gas flow at 15 °C and 1013 mbar g/h

-

-

-

-

-

73

73

-

-

73

* For France and Belgium
** For G30 (50 mbar), nozzle set HEZ298070 must be ordered from our after-sales service.

*G20/G25 G20

G20

G25

G25

G30/G31

**G30 G25.1 G27

G30

Gas pressure (mbar)

20/25

20

25

20

25

28-30/37

50

25

20

37

Nozzle (mm)

0.97

0.97

0.91

1

0.94

0.65

0.58

0.94

1.00

0.62

Bypass nozzle (mm)

0.58

0.58

0.58

0.58

0.58

0.38

0.38

0.58

0.58

0.38

Max. input power (kW)

1.75

1.75

1.75

1.75

1.75

1.75

1.75

1.75

1.75

1.75

Min. input power (kW)

 0.9

 0.9

 0.9

 0.9

 0.9

 0.9

 0.9

 0.9

 0.9

 0.9

Gas flow at 15 °C and 1013 mbar m³/h 0.167/

0.194

0.167

0.167

0.194 0.194 -

-

0.194 0.203 -

Gas flow at 15 °C and 1013 mbar g/h

-

-

-

-

-

127

127

-

-

127

* For France and Belgium
** For G30 (50 mbar), nozzle set HEZ298070 must be ordered from our after-sales service.

Содержание HX423210N

Страница 1: ...04 150296 Ú Instructions for connecting gas and gas conversion for After Sales Service only 2 é Aanwijzing voor de gasaansluiting en omschakeling Alleen voor de klantenservice 11 ...

Страница 2: ... rating plate If there is no symbol for your country follow the technical guidelines that apply in your country when making settings Before setting up the appliance determine the gas type and pressure in the local supply network Before using the appliance for the first time make sure that all settings have been made correctly Pay attention to local and international rules and regulations All conne...

Страница 3: ... and tighten this 4 To perform a leak test see the section entitled Leak test Open the gas supply Notes G EN ISO 228 G TS EN ISO 228 G A torque spanner must be used when the gas is connected Connection in accordance with EN 10226 R TS 61 210 EN 10226 R 1 Place the new seal on the connecting piece Make sure that the seal is correctly seated 2 Attach the connecting piece with a size 24 key to the en...

Страница 4: ...n and grill nozzles must also be replaced Numbers are printed on the nozzles indicating their diameter Further information about the gas types suitable for the appliance as well as the corresponding gas nozzles can be found in the section entitled Technical properties gas After the conversion After the appliance has been converted to a different gas type you must perform a leak test See the sectio...

Страница 5: ... to the control panel and pulling them straight out Converting the appliance from natural gas to liquefied gas If the appliance was set to natural gas at the time of delivery factory setting NG G20 G25 and is now being converted to liquefied gas for the first time LPG G30 G31 For models with safety pilot In order to reach the bypass nozzles the control panel must be removed See the section Removin...

Страница 6: ...s and burner parts 3 If there are any burner connection screws in the hob remove them all 4 Remove the two screws T20 at the front right and left of the hob panel Do not remove the plastic parts underneath 5 For models with a wok burner optional Remove the four screws M4 from the wok burner 6 Hold the hob panel at the front and tilt it upwards at an angle of no more than 30 Use the profile bar whi...

Страница 7: ... straight down into the holder 7 Fit burner housings of the correct size onto each burner and ensure that the spark plug is inserted into the opening on the edge of the burner housing Place the enamelled burner caps in the centre of the matching burner bases 8 Refit the pan supports Make sure that the 80 mm wide pan support is fitted on the auxiliary burner 9 Fit the control knobs carefully 10 At ...

Страница 8: ... the part closed with the blind plug Checking the burner nozzles 1 Open the gas supply Carry out the leak test separately for each nozzle 2 Carefully close the hole in the burner nozzle to be checked using your finger or a suitable device 3 Spray the nozzle with a leakage spray 4 Press the function selector and turn it anti clockwise This supplies the nozzle with gas If small bubbles or foam form ...

Страница 9: ... but after a few minutes the flames should burn constantly 3 To check that the thermocouple is functioning correctly let the appliance run for a few minutes If necessary check the settings If it is not functioning correctly replace the bypass screw in the burner Technical data Gas Different types of gas and the corresponding values are listed here Nozzle values for the auxiliary burner Nozzle valu...

Страница 10: ... 0 46 Max input power kW 3 3 3 3 3 3 3 3 3 3 Min input power kW 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 Gas flow at 15 C and 1013 mbar m h 0 285 0 332 0 285 0 285 0 332 0 332 0 332 0 348 Gas flow at 15 C and 1013 mbar g h 218 218 218 For France and Belgium For G30 50 mbar nozzle set HEZ298070 must be ordered from our after sales service G20 G25 G20 G20 G25 G25 G30 G30 G25 1 Gas pressure mbar 20 25...

Страница 11: ...keurig in acht Indien voor uw land geen symbool aanwezig is moet u zich bij de instellingen houden aan de technische richtlijnen van uw land Voordat u het apparaat opstelt moet u bij uw gasleverancier informatie inwinnen over de gassoort en gasdruk Verzeker u vóór de inbedrijfstelling van het apparaat ervan dat alle instellingen correct zijn uitgevoerd Plaatselijke en internationale regelingen en ...

Страница 12: ...i deze stevig aan 4 Lees voor de uitvoering van een lektest het hoofdstuk Lektest na Open de gastoevoer Aanwijzingen G EN ISO 228 G TS EN ISO 228 G Bij de aansluiting van het apparaat moet een torsiesleutel worden gebruikt Aansluiting volgens EN 10226 R TS 61 210 EN 10226 R 1 Plaats de nieuwe afdichting op het aansluitstuk Let erop dat de afdichting goed op haar plaats zit 2 Bevestig het aansluits...

Страница 13: ...van de standaardgasinstelling moeten de bypass schroeven van de branderkranen óf vervangen óf tot aan de aanslag ingedraaid worden Indien aanwezig moeten ook de oven en grillsproeiers worden vervangen Op de sproeiers staan getallen die de diameter aangeven Meer informatie over gassoorten die voor het apparaat geschikt zijn vindt u in het hoofdstuk Technische eigenschappen gas Na de omzetting Na de...

Страница 14: ...eningspaneel vast te houden en vervolgens recht eruit te trekken Omschakeling van aardgas naar vloeibaar gas Wanneer het apparaat bij levering standaardinstelling op aardgas NG G20 G25 was ingesteld en nu voor het eerst naar vloeibaar gas LPG G30 G31 wordt omgeschakeld Voor modellen met ontbrandingsbeveiliging Om bij de bypass koppen te kunnen komen moet het bedieningspaneel worden gedemonteerd Zi...

Страница 15: ...vasthouden en naar boven trekken De afscherming komt los Let erop dat de scharnieren niet kwijtraken 2 Pannenhouders en branderonderdelen verwijderen 3 Alle mogelijk aanwezige brander aansluitschroeven van de kookplaat verwijderen 4 De twee schroeven T20 rechts en linksvoor op de kookplaat afnemen De kunststof onderdelen die zich daaronder bevinden niet verwijderen 5 Voor modellen met wokbrander o...

Страница 16: ...n in de bevestigingsklemmen plaatsen 2 De beide schroeven T15 M4 die van het bedieningspaneel zijn afgenomen weer indraaien 3 De schroeven T20 die aan de rechter en linkerkant uit de frontprofielen zijn gehaald weer inbrengen De kunststof afschermingen weer aanbrengen 4 De kookplaat voorzichtig inbrengen Let erop dat de kunststof onderdelen onder de schroeven er niet uitvallen De beide schroeven T...

Страница 17: ...aat van de grillbrander en de grillbrander met elkaar verbindt en trek de brander voorzichtig recht eruit Let erop dat het thermo element en de bougieaansluitingen niet worden beschadigd De brandersproeiers zijn nu vrij toegankelijk 3 Draai de sproeier van de grillbrander los steeksleutel van 7 mm 4 De nieuwe sproeier die voor de omgezette gassoort nodig is kunt u met behulp van de tabel bepalen Z...

Страница 18: ...t er gas naar de sproeier Indien zich kleine belletjes of schuim vormen duidt dit op een gaslek Volg de instructies op in het hoofdstuk Wat te doen bij een gaslek Correcte vlamvorming Branders Na de omzetting naar een andere gassoort moet voor elke brander de vlamvorming en temperatuurontwikkeling worden gecontroleerd Vergelijk in geval van een probleem de sproeierwaarden met de waarden in de tabe...

Страница 19: ...20 37 Kop mm 0 97 0 97 0 91 1 0 94 0 65 0 58 0 94 1 00 0 62 Bypass kop mm 0 58 0 58 0 58 0 58 0 58 0 38 0 38 0 58 0 58 0 38 Ingangsvermogen max kW 1 75 1 75 1 75 1 75 1 75 1 75 1 75 1 75 1 75 1 75 Ingangsvermogen min kW 0 9 0 9 0 9 0 9 0 9 0 9 0 9 0 9 0 9 0 9 Gasverbruik bij 15 C en 1013 mbar m h 0 167 0 194 0 167 0 167 0 194 0 194 0 194 0 203 Gasverbruik bij 15 C en 1013 mbar g h 127 127 127 Voor...

Страница 20: ...enst worden besteld G20 G25 G20 G20 G25 G25 G30 G30 G25 1 Gasdruk mbar 20 25 20 25 20 25 28 30 50 25 Kop mm 1 00 1 00 0 98 1 13 1 10 0 70 0 62 1 10 Bypass kop mm Ingangsvermogen max kW 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 Ingangsvermogen min kW Gasverbruik bij 15 C en 1013 mbar m h 0 2 0 233 0 2 0 2 0 233 0 233 0 233 Gasverbruik bij 15 C en 1013 mbar g h 153 153 Voor Frankrijk en België Voor G30 50 mba...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ... 9000713468 9000713468 ...

Отзывы: