3.2 Service procedures for Gigaset SL100/ 150 base station
Press: "menu-key", 8, 9, ABCD (see table below), o.k.
Pos. acknowledge tone (rising sequence of notes) = Procedure has been accepted.
Feature
A
B
C
D (Option)
Read out RFPI number of base station
1 - 0
-
Pause after access code
and
length of dial pause ("P")
1
-
1 1 = 1 sec.
2 = 2 sec.
3 = 3 sec.
4 = 6 sec.
Pause after signal-key
1
-
2 1 = 800 ms
2 = 1600 ms
3 = 3200 ms
Automatic attenuation correction
(dependant on country)
1
-
3 0 = off
1 = on
Time for end of call identification
(to distinguish between 2 ringing pulses of
one call with long pauses between pulses
and 2 separate calls)
1
-
4 0 = 4 sec.
1 = 5.5 sec.
2 = 7 sec.
3 = 11 sec.
4 = 2.5 sec.
Hook-flash-prevention
(cradle switch
identification) (short press on cradle switch-
key is extended by SW to prevent that it is
interpreted as a press on the flash-key)
1
-
5 0 = 800 ms
1 = 2000 ms
Pause after line seizure
1
-
6 1 = 1 sec.
2 = 3 sec.
3 = 7 sec.
Music on hold
1
-
7 0 = off 1 = on
Read customer settings
1
-
8
- (see
description below)
*
Suppress first call if SMS is activated
1
-
9 0 = no 1 = yes
System PIN reset
3 76200 -
-
Programming data on an address
4 76200 1 Specific
code
needed
Read out SW-version
(decimal figures)
4 76200 2 Example:
01
002
00 …
01 = SW-variant
002 = SW-version
00 = Revision
Range of ringing frequency recognition
4 76200 3 0 = 20- 60 Hz
1 = 15- 75 Hz
2 = other settings
Dial pulsing:
pulse pause ratio
(make break ratio)
4 76200 4 0 = 1.5 : 1
1 = 2 : 1
CLIP list activation
4 76200 5 0 = on 1 = off
Off-hook CLIP activation
4 76200 6 0 = off 1 = on
Approval test
6 76200 5
-
Working time
7 - 1
-
see
**