background image

GAMMA wave 

Technical Product Information 

February 2007 

Switch actuator wave GE 561/01 

5WG3 561-4AB01 

 

 

Technical Manual 

wave GE 561/01, 6 pages 

Siemens AG 

 

 

Automation and Drives Group 

Update: http://www.siemens.de/gamma 

©

 Siemens AG 2007 

Electrical Installation Technology 

 

Subject to change without prior notice 

P.O. Box 10 09 53, D-93009 Regensburg 

2.20.8.1/2 
 

Electromagnetic compatibility 

 complies 

with 

EN 

300220,

 

EN 301489, EN 60669-2-1 

 

Environmental specifications 

  Climatic conditions: EN 50090-2-2 

  Ambient operating temperature: - 5  + 45°C 

  Storage temperature: - 25   +70°C 

  Relative humidity (non-condensing): 5% to 93% 

 

Certification 

 complies 

with   - standard 

 

- radio frequency wave 

 

- easy mode push button EP 

 

 

 

CE norm 

complies with the EMC regulations, low voltage regula-
tions and R&TTE regulations 
 
SIEMENS AG hereby states that the switch actuator 
wave GE 561/01 is in compliance with the basic re-
quirements and the other relevant provisions of Regula-
tion 1999/5/EC. 
 
The CE declaration can be inspected at: 
 
SIEMENS AG 
Siemensstraße 10 
93055 Regensburg, Germany 
 
 

Installation instructions 

 

Caution: 

  Installation of the device in metal walls and ceilings 

should be avoided, since the range of radio control is 
thereby substantially reduced. 

  Occasionally the transmission range may be influ-

enced by structural factors (e.g., reinforced concrete) 
or electric/electronic sources of interference. 

  A distance of at least 1 m must be maintained be-

tween the transmitter and the relevant receivers. 

  Although the radio transmission occurs in the safe 

868 MHz frequency band, interference in the radio 
transmission cannot be ruled out. 

  The radio transmission used is not suitable for secu-

rity applications. 

 
 
 

V

  

DANGER

 

  The device may be used only in dry interior rooms, 

for installation in equipment, housings or under cov-
ers. 

  The device must be mounted and commissioned by 

an authorized electrician. 

  The device must not be opened. 

  The prevailing safety and accident regulations must 

be observed. 

  In the planning and installation of electric facilities, 

the relevant regulations, provisions and terms of the 
respective country must be observed. 

  An insulated tool (e.g. a screwdriver with insulation) 

should be used to operate the pushbutton. 

 
 

Mounting 

 
General description 
The device is attached with two screws 4 mm 

 (bore 

spacing 251 mm central). 
 
Opening the terminal chamber (Diagram B) 
Press the snap-in lever (B1) down and outwards (black 
arrow) and flip up the cover of the terminal chamber 
(B2). 
 
Closing the terminal chamber (Diagram B) 
Press down and snap in the cover of the terminal cham-
ber (B2) and screw in the locking screw (B3). 
 
 

B2

B1

5

1

2   L1

3   N

4   L2

A

B

5WG3 561-4AB01
GAMMA wave

Schaltaktor wave GE 561/01
Switch actuat or wave GE 561/01
Un ~ 230V / In 16A / 50Hz

 

Made in Germany

 

µ

µ

 EP

~230V

!

 

 

B1

B2

B3

 

 

Diagram B 

 
 
 

Содержание GAMMA wave GE 561/01

Страница 1: ...led on the top of the device and an LED to display the operation condi tions in the special function operating mode The Special Function operating mode includes the fol lowing functions Connecting radio sensors with the function switching ON OFF or scene Activating deactivating the time switch function Clearing connections to radio sensors Resetting the device to the supplied state Technical Speci...

Страница 2: ...ctural factors e g reinforced concrete or electric electronic sources of interference A distance of at least 1 m must be maintained be tween the transmitter and the relevant receivers Although the radio transmission occurs in the safe 868 MHz frequency band interference in the radio transmission cannot be ruled out The radio transmission used is not suitable for secu rity applications V DANGER The...

Страница 3: ...iver will be reduced and telegram losses may thereby occur 1 2 3 4 5 Kanal 1 L 1 N L 2 Kanal 2 C1 C2 C3 C4 Diagram C C1 Screw terminals C2 Wire fixing C3 Pushbutton C4 LED 1 2 L1 3 N 4 L2 5 Diagram D Terminal assignment Diagram D 1 Load output channel A 2 L1 Power supply L for actuator electronics and channel A 3 N Power supply N for actuator electronics 4 L2 Power supply L for channel B 5 Load ou...

Страница 4: ...utton F2 for the duration of up to 3 seconds switches the actuator to the special function channel A operating mode This is displayed by a slow flashing with approx 0 5 Hz once in 2 seconds of the LED F3 Special function for channel B A long actuation of the pushbutton F2 for the duration of 3 to 6 seconds switches the actuator to the special function channel B operating mode This is displayed by ...

Страница 5: ... B of the switch actua tor are deleted The device is in the supplied state If the pushbutton remains pushed for a maximum of 3 seconds or for 3 to 6 seconds after resetting to the sup plied state it will be directly switched to the special function channel A or special function channel B Time switch operation on period 1 to 60 minutes The two channels of the switch actuator wave can be operated re...

Страница 6: ...F3 begins to flash slowly once in 2 seconds with approx 0 5 Hz upon release of the pushbutton within 3 seconds or 1B Switch on special function channel B Action Long actuation of the pushbutton F2 for the duration of 3 to 6 seconds Display After 3 seconds the LED F3 flashes briefly approx 0 1 sec once After the release of the pushbutton within 3 to 6 seconds the LED shows a steady light 2 Select t...