11
en
Operating instructions
Please read and observe the detailed safety instructions
at the start of these instructions!
■
Important:
The appliance may never be exposed to frost!
Risk of electric shock!
Switch off the mains voltage supply immediately if
a fault occurs.
■
Immediately shut off the cold water supply to the appli-
ance should it leak.
Getting to know your appliance
The continuous-flow heater heats the water as it flows
through the appliance. The appliance only consumes power
during this period.
D
Operating elements
The continuous-flow heater has two heat settings:
e
Economy setting – two thirds power
II
Intensive setting – full power
The
e
setting is ideal for:
Wash basin
Shower
Bidet
The
II
setting is used in combination with a thermostatically-
controlled premixer, for high temperatures or for large vol-
umes of water, e. g. for:
Dishwashing
Cleaning
Bath tub
Operating the appliance
E
Turn on the hot-water tap
The continuous-flow heater switches on and heats the water
when the hot-water tap is turned on (
Fig. E, 1.
).
It switches off again when the tap is turned off.
Notes (not applicable for DH12...):
When the water tap is
turned on only slightly, the continuous-flow heater will oper-
ate at half power in both of the preselected settings (
e
,
II
).
When the water tap is turned on fully, the appliance will oper-
ate at full, preselected power.
E
Increasing the water temperature
Slightly close the hot-water tap (
Fig. E, 2.
).
E
Decreasing the water temperature
Turn on the cold-water tap (
Fig. E, 3.
).
Startup after a water cutoff
■
Disconnect the appliance from the mains supply (remove
the fuses in the fusebox).
■
Turn on the hot-water tap until the air is purged from the
pipe.
■
Reinstall the fuses.
The appliance is ready for operation.
Saving energy
Use the “
e
” setting whenever possible.
For wash basins: Open the corner valve to such an extent
that only the lower heat setting switches on.
Winter operation
Note:
It is possible in winter that the supply temperature of
the water is reduced and the required outlet temperature is
no longer achieved.
■
In order to compensate for this temperature reduction,
please reduce the water quantity on the tap until the re-
quired water temperature is achieved.
Cleaning
Simply wipe the appliance with a damp cloth.
Do not use acidic or abrasive cleaning materials.
Notes:
It is normally not necessary to descale the appliance.
However, extremely hard water and the frequent flows of
very hot water can cause the appliance to scale up. In this
case please contact our after-sales service.
After-sales service
If you call the after-sales service for assistance, please specify
the
E no.
and
FD no.
of your appliance.
These numbers are found on the inside of the swing-out con-
trol panel of the continuous-flow heater.
Содержание DH 12400
Страница 7: ...7 de 09 14 ...
Страница 35: ......
Страница 37: ...II 4 388 ca 96 70 44 100 ca 72 332 5 hot cold 100 1 2 3 ...
Страница 38: ...III 5 4 1 2 3 max 16 mm B ca 2 mm A 3 4 1 2 ...
Страница 40: ...V 3 4 6 5 min 40 mm 0 mm PE L3 L2 L1 min 40 mm 2 RESET 1 L1L2L3PE ...
Страница 41: ...VI 3 4 1 2 L 3 L 2 L 1 3 2 1 PE PE B 1 2 3 4 A ...
Страница 42: ...G 1 2 A 124 137 472 236 20 100 332 42 388 C D 1 2 3 E ...
Страница 75: ...10 13 ...
Страница 76: ...BSH Hausgeräte GmbH Carl Wery Straße 34 81739 München GERMANY www siemens homeappliances com 9001071765 ...