RS485 interface 

Interface type 

RS485, (electrically isolated) 

 

Baud rate, data bits / stop bit(s), parity 

As for RS232 (depends on software) 

 

 

Cable type 

Cable length 

Standard RS bus cable 

Max. 1200 m 

Plug-in screw terminal 

 

Solid or stranded conductors 

0.25…2.5 mm2 or 2 x 1.5 mm2 

Simple cable lengths, cable 

types 

Connection cable 

Ethernet and

 

PXM20-E

  Max. 100 m 

  Cable type 

Standard at least CAT5  

UTP (Unshielded Twisted Pair)  

or STP (Shielded Twisted Pair) 

Connection cable 

L

ON

W

ORKS

 bus

 

See Installation Guide CA110396 

  Cable type 

CAT5 

 

 

 

Housing protection standard Protection standard 

IP 20 to IEC 60529 

Protection class 

Protection class 

III to EN 60730 

 

 

 

Ambient conditions 

Normal operation 

To IEC 60721-3-3 

 

  Environmental conditions 

Class 3K5 

 

   

Temperature 

0...50 °C 

 

   

Humidity 

5…95 % r.h. (non-condensing) 

 

  Mechanical conditions 

Class 3M2 

 

Transport 

To IEC 60721-3-2 

 

  Environmental conditions 

Class 2K3 

 

   

Temperature 

-25…70 °C 

 

   

Humidity 

5…95 % r.h. (non-condensing) 

 

  Mechanical conditions 

Class 2M2 

 

 

 

Standards, directives and 

approvals 

 

 

 

Product standard 

EN 60730-1 

 

 

CM1T9223xx

 

 

 

CM1T9222en_C1

 

 

 

  

Zertifikat

  

 

AMEV: Supports profiles AS-A and AS-B to 

AMEV directive "BACnet in public 

buildings" 

BACnet 2011, V1.1

 

 

 

http://database.ul.com/

 

 

Document download 

www.hqs.sbt.siemens.com/gip/general/dlc/dl

c_mobile_direct.asp?BPZ:PXC001

 

 

 

Environmental compatibility 

 

 

The product environmental declaration 

CM1E9223 contains data on 

environmentally compatible product design 

and assessments (RoHS compliance, 

materials composition, packaging, 

environmental benefit, disposal) 

ISO 14001 (Environment) 

ISO 9001 (Quality) 

 

 

 

Dimensions 

See “Dimensions” 

 

Weight 

Without / with packaging 

 

PXC001.D, PXC001-E.D 

 

PXA-40-RS1, PXA40-RS2 

 

0.635 kg / 0.731 kg 

0.048 kg / 0.060 kg 

 

 

 

 

8 / 10 
Siemens 

PXC001   System controllers 

CM1N9223en_01 

Building Technologies 

 

2014-04-04 

Содержание DESIGO PX Series

Страница 1: ...omation level via BACnet System controllers for the integration of Desigo RXB RXL room controllers Native BACnet devices with communication via BACnet LonTalk or BACnet IP BTL label BACnet communications passed the BTL test Comprehensive management and system functions alarm management time scheduling trends remote management access protection etc Supports operation via local or network compatible...

Страница 2: ...m Controller for the integration of KNX M Bus Modbus or SCL over BACnet LonTalk PXC001 D System Controller for the integration of KNX M Bus Modbus or SCL over BACnet IP PXC001 E D Option modules Type Up to 800 data points PXA40 RS1 SCL up to 1000 data points M Bus and Modbus up to 2000 data points PXA40 RS2 Equipment combinations PXC001 D PXC001 E D PXA40 RS1 PXA40 RS2 Interfaces KNX X Serial RS23...

Страница 3: ... screw terminal block RS485 11 RS232 interface 12 Plug in screw terminal block KNX 13 RJ45 interface ETS tool for service use 14 KNX programming pin 15 RJ45 interface for operator unit or PX KNX tool 16 Slider for mounting on DIN rail PXA40 RS RX TX SERVICE RX TX RS232 RS485 KNX SERVICE INFO COMM LOW BATT FAULT RUN HMI TOOL HMI 5 4 CLB CLA 1 2 3 6 7 8 RS485 RS232 9 10 CE SERVICE KNX TOOL CE 2b 922...

Страница 4: ...Continuously OFF Continuously ON Flashing Flashing per wink command OK No connection to switch No IP address configured Physical identification of system controller after receipt of wink command SERVICE LonTalk PXC001 D Red Continuously OFF Continuously ON Flashing Flashing per wink command LONWORKS node is configured Faulty LONWORKS chip or service pin currently depressed LONWORKS node is not con...

Страница 5: ...ique identification in the network BACnet IP or BACnet LonTalk press the Service button with a long pointed object or send a wink command to the appropriate system controller service LED blinks Variant via V24 If the Force Firmware Download Key is pressed for approx 10 s during a restart reset the current D MAP program is deleted from the FLASH The system controller waits briefly for the signal to...

Страница 6: ...as power Insert new battery correctly Note the special disposal notes on Li batteries A wrist strap and grounding cable must be used to avoid hardware damage through electrostatic discharge ESD Firmware and operating system stored in non volatile Flash ROM Flash ROM memory can be easily updated on the plant when a new firmware version is available Disposal The devices are classified as waste elect...

Страница 7: ... Level Network LonWorks FT5000 Transceiver Twisted Pair 78 kBit s Screw terminals BACnet on UDP IP IEEE802 3 Auto sensing 10 Base T 100 Base TX RJ45 shielded Local Communication HMI Tool PXM10 RS232 PXM20 BACnet LonTalk RJ45 Tool RJ45 Local Communication HMI PXM10 RS232 PXM20 BACnet LonTalk RJ45 PXM10 RS232 One PXM10 operator unit and one PXM20 per system controller may be connected But not twice ...

Страница 8: ...Mechanical conditions Class 3M2 Transport To IEC 60721 3 2 Environmental conditions Class 2K3 Temperature 25 70 C Humidity 5 95 r h non condensing Mechanical conditions Class 2M2 Standards directives and approvals Product standard EN 60730 1 CM1T9223xx CM1T9222en_C1 Zertifikat AMEV Supports profiles AS A and AS B to AMEV directive BACnet in public buildings BACnet 2011 V1 1 http database ul com Do...

Страница 9: ... 8 7 6 5 43 2 1 1 KNX data CE 2 KNX data CE 3 Not used 4 Not used 5 Not used 6 Not used 7 Not used 8 Not used 9281z04 1 2 3 4 5 6 7 8 9 1 DCD Data carrier detect 6 DSR Data set ready 2 RXD Received data 7 RTS Request to send 3 TXD Transmit data 8 CTS Clear to send 4 DTR Data terminal ready 9 NC Not connected 5 GND Signal ground Plug in screw terminal block 6 Tx 7 Rx 8 Screen connected to functiona...

Страница 10: ... 143 46 15 38 5 50 8 70 256 271 5 133 5 149 4 90 44 3 32 5 9223M01 All dimensions in mm 2014 Siemens Switzerland Ltd Subject to change 10 10 Siemens PXC001 System controllers CM1N9223en_01 Building Technologies 2014 04 04 ...

Отзывы: