A fault, what to do?

If the fault could not be eliminated, please call customer service.

Fault

Cause

Solution

Who

Water flow-rate is too low.

The filter in either the water tap 
or the showerhead is clogged.

Remove the filter and either 
clean it or descale it.

Customer

The filter in the corner regulating 
valve is clogged.

Clean the filter.

Servicing expert

The desired water temperature 
is not reached.

The power limit has been 
reached. Water flow-rate is too 
high and/or the cold water 
supply temperature is too low.

Reduce the flow-rate at the 
water faucet supply.

Customer

The power limit has been 
reached. Water flow-rate is too 
high and/or the cold water 
supply temperature is too low.

Use the angle valve to regulate 
the flow-rate. 
Check the flow-rate limiter or 
replace it with a smaller one.

Servicing expert

The desired water temperature 
is not reached.

The continuous-flow heater is 
connected to a thermostatically-
controlled water faucet.

The temperature at the con-
tinuous-flow heater must be set 
to max.

Customer

The water is not warm.

The fuse in the house electrical 
installation has triggered/blown.

Check the fuse in the house 
electrical installation.

Customer

The appliance’s automatic 
circuit breaker has been 
triggered.

Check the appliance’s auto-
matic circuit breaker. Check the 
permissible supply temperature.

Servicing expert

From time to time, cold water 
flows out.

The air sensor in the appliance 
detects air in the water and 
momentarily switches the 
heating element off.

After a few seconds, the 
continuous-flow heater 
automatically goes back into 
operation.

Continuous-flow heater 
automatically resolves 
problem

GB

Содержание DE 12400

Страница 1: ...018 DE 40021 DE 40024 Montageanweisung 2 Installation Instructions 5 Manuel de montage 8 Montagehandleiding 11 Instrukcja monta u 14 Instrucciones de instalación 17 Manual de instalação 20 Инструкция по монтажу 23 26 DE GB FR NL PL ES PT RU HK ...

Страница 2: ...ge müssen die unbenutzten Öffnungen wasserdicht ver schlossen werden Spannungsführende Teile dürfen nach der Montage nicht mehr berührbar sein Montage Auspacken Haube abnehmen Gerät auspacken und auf Transportschäden kontrollieren Verpackung und gegebenenfalls Altgerät umweltgerecht entsorgen Montagevorbereitung Wandmontage Der Durchlauferhitzer muss fest an der Wand montiert werden Befestigen Sie...

Страница 3: ...uf 38 C l min 7 3 9 9 11 6 13 2 12 C auf 60 C l min 3 9 5 4 6 3 7 2 Einschaltmenge l min 2 6 2 6 2 6 2 6 Einschaltfließdruck MPa bar 0 025 0 25 0 025 0 25 0 025 0 25 0 025 0 25 Fließdruck bei Nennleistung und 60 C mit Durchflussbegrenzer MPa bar 0 022 0 22 0 028 0 28 0 035 0 35 0 048 0 48 ohne Durchflussbegrenzer MPa bar 0 007 0 07 0 013 0 13 0 020 0 20 0 026 0 26 Einsatzbereich in Wässern Spezifi...

Страница 4: ...urchfluss über das Eckventil regulieren Den Durchflussbegrenzer kontrollieren oder einen kleineren einsetzen Fachmann Die eingestellte Wassertemperatur wird nicht erreicht Der Durchlauferhitzer ist an eine Thermostat Mischbatterie angeschlossen Die Temperatur muss am Durchlauferhitzer auf max eingestellt werden Kunde Das Wasser wird nicht warm Die Sicherung in der Hausinstallation hat ausgelöst Di...

Страница 5: ...d check for transportation damage Dispose of the packaging and where applicable the old appliance in an environmentally conscious manner Preparation for assembly Wall mounted assembly The continuous flow heater must be fitted securely to the wall If required secure the appliance using the lower adjusting screws The distance from the wall is variable This allows you to compensate for any unevenness...

Страница 6: ...38 C l min 7 3 9 9 11 6 13 2 12 C to 60 C l min 3 9 5 4 6 3 7 2 Switch on quantity l min 2 6 2 6 2 6 2 6 Switch on flow pressure MPa bar 0 025 0 25 0 025 0 25 0 025 0 25 0 025 0 25 Flow pressure at rated power and 60 C With flow limiter MPa bar 0 022 0 22 0 028 0 28 0 035 0 35 0 048 0 48 Without flow limiter MPa bar 0 007 0 07 0 013 0 13 0 020 0 20 0 026 0 26 Operative range in waters of specific ...

Страница 7: ...late the flow rate Check the flow rate limiter or replace it with a smaller one Servicing expert The desired water temperature is not reached The continuous flow heater is connected to a thermostatically controlled water faucet The temperature at the con tinuous flow heater must be set to max Customer The water is not warm The fuse in the house electrical installation has triggered blown Check the...

Страница 8: ...iemens Electrogeräte GmbH Carl Wery Str 34 81739 München Germany Family Line 01805 2223 Siemens Hausgeräte Besuchen Sie uns im Internet http www siemens de hausgeraete 5650038525 Printed in Germany 04 05 ...

Страница 9: ...I 5 3 4 4 1 1 2 ...

Страница 10: ...II 100 1 2 3 4 388 ca 96 70 44 100 ca 72 332 5 ...

Страница 11: ...III max 17 mm max 31 mm ca 2 mm ca 16 mm 3 4 2 1 ...

Страница 12: ...ç 1 minut Proplachovat 1 minutu U U U Ud d d da a a al l l li i i it t t t v v v vo o o oz z z zd d d du u u ux x x x v v v v t t t te e e eh h h he e e en n n ni i i ie e e e 1 1 1 1 m m m mi i i in n n nu u u ut t t ty y y y Odstraniti vazduh 1 minut Odzraãivati 1 minutu àÕ ÕÕ 1 π warm hot chaude caliente heet goràcy tepl goräheij toplo toplo πÌÈ ÑÕπ ...

Страница 13: ...V min 40 mm 0 mm 1 2 RESET L1L2L3PE min 40 mm L1 L2 L3 PE 3 4 6 5 ...

Страница 14: ...VI 3 4 1 2 5 6 7 8 L 3 L 2 L 1 3 2 1 PE PE 2 1 3 A B LED C ...

Страница 15: ...eraturas elevadas ou grandes caudais de água p ex Lavar a louça Limpezas Abrir a torneira deágua quente Quando a torneira de água quente é aberta o aquecedor é ligado e aquece a água Ele volta a desligar se quando a torneira é fechada Se a temperatura de entrada for alterada a temperatura de saída também é respectivamente modificada Aumentar a temperatura da água Se com a torneira de água quente t...

Страница 16: ...robinet régulateur à équerre est bouché Ouvrez le robinet d eau chaude en grand puis ouvrez et fermez à plusieurs reprises le robi net régulateur à équerre Ensuite nettoyez le crible du robinet d eau L appareil s arrête pendant le prélèvement d eau chaude la température de l eau baisse Insérez dans le robinet d eau chaude un joint qui ne gonfle pas Si vous ne pouvez pas remédier à la panne coupez ...

Отзывы: