5 Performance Data

B4A

41

CP 443-1 Advanced for Industrial Ethernet / Manual Part B4A

Release 01/2007
C79000-G8976-C193-06

5.11

Characteristic Data of the Integrated 4

Port Switch 

Learning addresses / deleting addresses (aging time)

The 4-port switch integrated in the CP automatically learns the addresses of the
DTEs connected via a port by evaluating the source addresses in the data
packets. If the switch receives a data packet, it directs this packet only to the port
via which the appropriate DTE can be obtained.

The switch monitors the age of the learned addresses. Addresses that exceed the
“aging time” are deleted.

The aging time set on the CP 443-1 Advanced is 5 minutes.

Ports can be deactivated individually

The individual ports of the 4

port switch integrated in the CP can be deactivated in

STEP 7 / HW Config. This can, for example, be used for service purposes.

The port is turned off completely when it is deactivated. The LINK and RX/TX
LEDs are turned off.

Содержание CP 443-1

Страница 1: ...LED displays Mode selector Ind Ethernet interface 4 x 8 pin RJ 45 Socket MAC address label C PLUG Port 1 Port 2 Port 3 Port 4 CP 443 1 Advanced 6GK7 443 1EX40 0XE0 Version 2 or higher Firmware Version V2 2 for SIMATIC S7 400 Release 01 2007 C79000 G8976 C193 06 ...

Страница 2: ...is supplied with a MAC address preset in the factory To ensure a unique address assignment we recommend that you use this MAC address when configuring the module Additional Documentation on IT Functionality Note Please refer to the detailed description of IT functionality in the Manual Information Technology in SIMATIC S7 5 The CP 443 1 Advanced described here differs slightly In terms of the orga...

Страница 3: ...ternet http www4 ad siemens de view cs en 8777865 Contents Part B6 Notes on the Product B4A 2 Contents B4A 3 1 Properties and Services B4A 6 2 Requirements for Use B4A 11 3 Installation and Commissioning B4A 14 3 1 Procedure Steps in Installation B4A 14 3 2 C PLUG Configuration Plug B4A 17 3 3 Module Replacement without PG B4A 19 4 Displays and Mode Selectors B4A 21 5 Performance Data B4A 24 5 1 G...

Страница 4: ...ard Communication at the same Time B4A 51 8 The CP 443 1 Advanced as Web Server HTML Process Control B4A 53 9 Compatibility with Predecessor Products B4A 54 9 1 Enhanced Functions B4A 54 9 2 Restrictions B4A 56 9 3 Replacing Older Modules B4A 57 10 Further Notes on Operation B4A 59 10 1 Memory Reset Resetting the to the Factory Settings B4A 59 10 2 Working with Fast Ethernet automatic switchover B...

Страница 5: ...1 2007 C79000 G8976 C193 06 10 12 Accessible Nodes Function Requires the Current STEP 7 Version B4A 73 10 13 IP Access protection LOG File in the File System B4A 73 10 14 Further Available Information on the CP B4A 73 11 Loading New Firmware B4A 74 12 Technical Specifications B4A 76 ...

Страница 6: ...Ind Ethernet S PROFINET CBA Use of a SIMATIC S7 400 for Component based Automation on the basis of the new PROFINET standard of the PNO This standard allows Component technology in automation Graphic configuration of communication between intelligent devices instead of laborious programming Vendor independent plant wide engineering S S7 communication with PG functions Operator monitoring and contr...

Страница 7: ...unctions Sending E mail Monitoring devices and process data HTML process control FTP functions File Transfer Protocol for file management and access to data blocks in the CPU client and server functions S Time of day synchronization over Industrial Ethernet according to the following configurable method SIMATIC mode The CP receives MMS time of day messages and synchronizes its local time You can c...

Страница 8: ...on establishment by the FC S S5 S7 addressing mode The addressing mode can be configured for FETCH WRITE access as the S7 or S5 addressing mode S7 addressing mode only for data blocks DBs S IP double addressing detected in the network To save you time consuming troubleshooting in the network the CP detects double addressing in the network When the CP starts up after power down or after the initial...

Страница 9: ...o be able to work in the PROFINET CBA environment you require the SIMATIC iMap engineering tool SIMATIC iMap requires a connection over Industrial Ethernet TCP IP protocol The following SIMATIC iMap project engineering software is required Table 1 2 Version of SIMATIC iMap Functions of the CP 443 1 Advanced V2 0 SP1 The full functionality of the device can be used as of hardware version 2 and firm...

Страница 10: ... of data fields 240 bytes S You require the blocks AG_SEND FC5 and AG_RECV FC6 or alternatively the blocks AG_LSEND FC50 and AG_ LRECV FC60 Transfer of data fields 240 bytes S You require the blocks AG_LSEND FC50 and AG_LRECV FC60 These blocks are shipped with NCM For a detailed description of these blocks refer to the general part of this manual Part A Notice We recommend that you always use the ...

Страница 11: ... be operated as PROFINET IO controllers S When operating the CP as a PROFINET IO controller multiprocessing is not supported in other words only process image of the assigned CPU can be distributed over the CP System Environment The CP 443 1 Advanced is supported by the S7 400 CPUs and CPU operating systems with the order numbers as shown in the following table S The function block FB90 PN_InOut_F...

Страница 12: ...CK PROFINET IO CPU412 412 1XF04 0AB0 V4 0 V4 1 3 3 14 24 24 CPU412 2 412 2XG04 0AB0 V4 0 V4 1 3 3 14 24 24 CPU414 2 414 2XG04 0AB0 V4 0 V4 1 3 3 14 24 24 CPU414 3 414 3XJ04 0AB0 V4 0 V4 1 3 3 14 24 24 CPU416 2 416 2XK04 0AB0 V4 0 V4 1 3 3 14 64 64 CPU416F 2 416 2FK04 0AB0 V4 0 V4 1 3 3 14 64 64 CPU416 3 416 3XL04 0AB0 V4 0 V4 1 3 3 14 64 64 CPU417 4 417 4XL04 0AB0 V4 0 V4 1 3 3 14 64 64 Legend the...

Страница 13: ...or example at a maximum of 64 possible AG_SEND calls At the absolute limit with 64 AG_RECV calls with long data sent at the same time no calls with AG_SEND can be sent because the available send resources are then occupied 2 Note The maximum value shown here applies to the CPU being used if several CPs are operated at the same time the maximum value applies unchanged to the total number of jobs is...

Страница 14: ... Advanced can be plugged into all racks with slots for P and K bus attachment The following racks are suitable S Central rack CR2 central unit S Universal rack UR1 or UR2 as central unit as expansion rack with rack number 1 6 only possible if PROFINET IO is not being used When the CP is installed in an expansion rack you only need to turn off the power supply for the expansion unit Notice When usi...

Страница 15: ...top or PG directly A crossover cable is not necessary Please note the following points S Manual configuration If a port is set to manual configuration the autocrossing mechanism is also deactivated for this port The port then behaves like the interface of a switch Which cable you can use depends on the partner device As default the ports are set for automatic configuration For more detailed inform...

Страница 16: ...ith STEP 7 S Communication diagnostics with NCM S7 Diagnostics S Standard information using HW Config 8 Optional when using with PROFINET CBA Download PROFINET CBA component If the S7 station in which the CP is operated is used as a PROFINET CBA component the interconnections are downloaded using SIMATIC iMap for more detailed information refer to the topic Using the CP with PROFINET CBA Caution R...

Страница 17: ...ata in the flash file system see also Flash Area in Section 5 10 Memory Organization S SNMP Variables modifiable This configuration plug simplifies replacement of modules By simply exchanging the plug all the data can be transferred to the replacement module Notice The CP will not start up without a C PLUG Area of Application The C PLUG is an exchangeable medium for storing configuration and proje...

Страница 18: ...aced much faster and more simply If a device needs to be replaced the C PLUG is simply taken from the failed component and inserted in the replacement As soon as it starts up the replacement automatically has the same device configuration as the failed device Using a C PLUG with old Configuration Data Use only C PLUGs that are formatted for the CP 443 1 Advanced C PLUGs that have already been used...

Страница 19: ... the section Compatibility Notice The Replace module without PG functionality configuration data stored on the CPU can no longer be used fully after downloading PROFINET CBA interconnections since the interconnection information is stored only on the CP You have the following two options S Adopt the C PLUG in a new module You insert the previously used C PLUG in the replaced module this makes the ...

Страница 20: ...s of the new module is sent to the DHCP server this will return either a different or no IP address Ideally you should therefore configure IP as follows Always configure a client ID if you want to obtain the same IP address from the DHCP server after replacing the module If you have configured a new MAC address instead of the factory set MAC address generally the exception the DHCP server always r...

Страница 21: ...only relevant for diagnostics CP Mode LED Displays INTF LED red EXTF LED red BUSF LED red RUN LED green STOP LED yellow CP Operating Mode Starting STOP RUN Running RUN Stopping RUN STOP Stopped STOP In the STOP mode it is still possible to configure and run diagnostics on the CP STOP with internal error or memory reset For example IP double addressing detected in the network In this status S The C...

Страница 22: ...gnal the CP mode the front panel and the RJ 45 socket also include LEDs that provide information about the status of the CP interface to Industrial Ethernet Table 4 1 LED Meaning LED on TXD LED green Flashing CP is sending over Ind Ethernet note in the current version it may also be permanently lit RXD LED green Flashing The CP is receiving over Ind Ethernet LINK green Indicates an established con...

Страница 23: ...e configuration and diagnostics of the CP is possible system connections for configuration diagnostics and PG channel routing are retained The downloading of interconnections for PROFINET CBA communication is not possible FTP access to the file system is possible HTTP access is possible The routing function is active The time of day is not forwarded PROFINET CBA is disabled PROFINET IO is disabled...

Страница 24: ...r example operate 64 S7 connections 30 ISO on TCP connections 10 TCP connections 10 UDP connections 8 ISO transport connections If you require FTP and HTTP access at the same time for FTP 2 x TCP connections and for HTTP 4 x TCP connections see Section 5 7 5 2 Characteristic Data for S7 Communication Table 5 2 Characteristic Explanation Values Total number of S7 connections on Industrial Ethernet ...

Страница 25: ... sure that the processing capabilities of a receiving CP are not permanently exceeded by the sender approximately 150 200 messages per second 2 TCP connections for FTP Of the available to CP connections a maximum of 20 TCP connections can be configured used with the Use FTP protocol option see Section 5 7 Maximum data length for AG_SEND and AG_RECV blocks AG_SEND and AG_RECV were shipped with pred...

Страница 26: ... loss of messages is not detected or displayed by the send blocks AG_SEND or AG_LSEND S Data field length The maximum length of the data fields is 2048 bytes S No reception of UDP broadcast To avoid overload resulting from a high broadcast load the CP does not permit reception of UDP broadcast As an alternative use multicast mode over a UDP connection this gives you the opportunity of registering ...

Страница 27: ...nual Part B4A Release 01 2007 C79000 G8976 C193 06 5 4 Characteristics of Open TCP IP Communication Table 5 4 Characteristic Explanation Values Number of dynamically generated connections over Industrial Ethernet S ISO on TCP connections 1 to 64 Max data length 1452 bytes ...

Страница 28: ...O device S Inputs S Outputs 128 bytes 128 bytes Size of the consistency area for a submodule 128 bytes Data record length 240 bytes max Supported data record numbers 0 to 255 Note Note the following for PROFINET IO If you use modules with 32 bytes of input output data this can lead to I O access errors access errors are entered in the diagnostic buffer of the CPU These I O errors occur during oper...

Страница 29: ...ata for PROFINET CBA Communication Characteristic Typical value Limit value with FB88 with FB90 PROFINET CBA Number of remote interconnection partners 32 64 Total of all I Os 600 600 Data length of all incoming I Os 3200 bytes 8192 bytes 1452 bytes Data length of all outgoing I Os 3200 bytes 8192 bytes 1452 bytes Data length for arrays and structures acyclic interconnections maximum 2048 bytes 819...

Страница 30: ...25 250 Data length of all incoming interconnections 1000 bytes 2000 bytes 1452 bytes Data length of all outgoing interconnections 1000 bytes 2000 bytes HMI variables over PROFINET acyclic Number of stations that can register for HMI variables PN OPC iMap Stations are 2 PN OPC and 1 SIMATIC iMap 3 HMI variable update 500 ms minimum Number of HMI variables 200 maximum Data length of all HMI variable...

Страница 31: ...uency of transmission is directly related to the actual cycle time For technical reasons the cycle time is based on powers of two of the basic cycle time of 1 ms The actual cycle time therefore corresponds to the next higher power of two of the configured transfer frequency This results in the following transfer frequency cycle time for the specified values 10 8 20 16 50 32 100 64 200 128 500 256 ...

Страница 32: ...or PROFINET CBA The additional line in the graphic shows the influence when you use the PROFINET CBA interface of a CP 443 1 Advanced in an S7 400 station It can be seen that in contrast to operation over a CPU network attachment the OB1 cycle remains practically uninfluenced by the CBA communication if PROFINET CBA is operated over a CP 443 1 Advanced 0 1 2 3 4 5 6 0 20 40 60 80 100 120 140 160 1...

Страница 33: ...ET IO or with services such as online monitoring As a result the reaction times for cyclic PROFINET CBA interconnections may exceed the configured value for the transfer frequency You should therefore check the reaction time that can be achieved during commissioning and if necessary change the project engineering Measurements in a Sample Configuration Measurements were made to help you to estimate...

Страница 34: ...r reduced and with longer cycle times they are correspondingly extended Measurement results From the following diagram you can see the average values for the reaction time of the cyclic interconnections depending on the size of the interface DB 0 10 20 30 40 50 60 70 0 480 960 1440 1920 2400 2880 Evaluation From the diagram you can see that the transfer frequencies configured at 10 ms or 20 ms in ...

Страница 35: ...ual Part B4A Release 01 2007 C79000 G8976 C193 06 Note The values of the utilization parameters displayed by SIMATIC iMap as of V2 0 with the Edit Check utilization function relate to the data exchange as far as the CP They do not apply to data access from the user program ...

Страница 36: ...locks a TCP connection must be configured with the Use FTP protocol option Of the available TCP connections a maximum of 20 TCP connections with the Use FTP protocol option can be configured used The following table shows the memory requirements of the FCs available for FTP services The block execution times in FTP depend on the reaction times of the partner and the length of the user data a gener...

Страница 37: ... Maximum Array Size The maximum array size for the CP 443 1 Advanced S is 400 bytes when writing data to the CPU and S 400 bytes when reading data from the CPU Note Please note that the maximum block size in bytes is specified here and that the maximum number of array elements is decided by the byte size of the array basic data type Example The CP 443 1 Advanced can transfer a maximum of 100 array...

Страница 38: ...ameters Flash file system RAM Area Volatile RAM file system ram Non volatile RAM file system sram Battery backed RAM area CPU data Configuration Data Data maintained on the S7 400 CPU SNMP Variables modifiable Interconnection information for PROFINET CBA 5 10 2 File Systems Notice Please refer to the detailed description of FTP functionality in the Manual Information Technology in SIMATIC S7 5 In ...

Страница 39: ...te on Figure 5 1 For the latest information on the configuration limits refer to the table on page B4A 40 or the current system page of your CP Meaning of the Memory Areas On the CP 443 1 Advanced the file system is divided into 3 areas S Flash Area in the C PLUG non volatile memory The flash area allows data to be stored and retained if there is a power down Since the number of times it is possib...

Страница 40: ...cated in the file system below the ram folder All files and folders below this folder are lost when there is a power down S Battery Backed RAM Area sram backed by the battery of the power supply The battery backed RAM area can be used in the same way as the volatile RAM described above This RAM is located in the file system below the sram folder If you turn off the power or if there is a power dow...

Страница 41: ...ata packets If the switch receives a data packet it directs this packet only to the port via which the appropriate DTE can be obtained The switch monitors the age of the learned addresses Addresses that exceed the aging time are deleted The aging time set on the CP 443 1 Advanced is 5 minutes Ports can be deactivated individually The individual ports of the 4 port switch integrated in the CP can b...

Страница 42: ...e you configure for PROFINET IO as follows To be able to use the CP as a PROFINET IO controller create a PROFINET IO system in STEP 7 HW Config You can either assign an existing or a new Ethernet subnet to the CP as the PROFINET IO system Then add the PROFINET IO devices to the PROFINET IO system STEP 7 automatically assigns addresses that you can modify if necessary The address information is sto...

Страница 43: ... automatically after power up or following a power outage Configuration Limits When using the CP type described here the following limits apply within an S7 400 station Number of CPs operating as PROFINET IO controllers 4 How PROFINET IO devices start up with a large operational configuration When operating the module with a large configuration up to 128 communication connections and up to 125 PRO...

Страница 44: ...s 6 2 Interface in the User Program SFBs and SFCs No special FBs or FCs are necessary for PROFINET IO operation The interfacing of the distributed I O is either direct or over SFCs SFBs of the CPU SFB52 RDREC SFB53 WRREC SFB54 RALRM SFC14 DPRD_DAT SFC15 WRRD_DAT SFC49 LGC_GADR SFC51 GD_SZL For a detailed description of these blocks functions refer to the System Software for S7 300 400 System and S...

Страница 45: ...7 C79000 G8976 C193 06 Further Information on PROFINET IO When setting up a PROFINET IO system please read the comprehensive system documentation S For PROFIBUS DP to PROFINET IO Programming Manual Siemens AG S PROFINET System Description The documents listed here are also on the Manual Collection CD supplied with every S7 CP ...

Страница 46: ...ly identically on the interface to the user program The following applies S The interface parameters are identical S FB90 has several additional condition codes in the STATUS parameter S There are differences in the configuration limits of the interface DB see Table 5 6 Please refer to the documentation of the blocks in the online help of STEP 7 or in the general part of this manual If you use the...

Страница 47: ...ce When you later configure the Ethernet interface make the following settings Disable the Set MAC address use ISO protocol option Notice ISO transport connections and S7 connections using the ISO protocol cannot be operated Note Running PROFINET CBA with a CP in the expansion rack is possible only as of STEP 7 V5 3 SP2 For more detailed information on adopting configuration data in the SIMATIC iM...

Страница 48: ...fic data The device specific configuration data and program data are located in the STEP 7 basic project of the PROFINET component For more detailed information refer to the documentation of SIMATIC iMap and the basic help of STEP 7 Representation in SIMATIC iMap S Network View in SIMATIC iMap The following graphic shows the network view of SIMATIC iMAP and illustrates how a CP 443 1 Advanced in a...

Страница 49: ... visible Here you can only see the PROFINET CBA components with their interconnections to the process inputs and process outputs S7 400 stations with CP 443 1 Advanced Assigning Addresses and Properties in SIMATIC iMap You can modify addresses and properties for singleton components such as an S7 400 station with CP 443 1 Advanced only in STEP 7 Downloading Configuration Data When you use the modu...

Страница 50: ...ns from SIMATIC iMap for example power down on the target station it is not always possible to download the interconnections again when the power returns If this error occurs SIMATIC iMap reports the station as being unreachable Remedy Using the module switch or the PG command change the CP 443 1 Advanced from STOP to RUN to bring the target station back an operational status and to allow the inte...

Страница 51: ...re we would like to give you a few tips and recommendations For communication between a PROFINET CBA device and a conventional device use S7 or TCP or ISO on TCP connections Configure the S7 and TCP connections in STEP 7 as follows S for S7 communication PROFINET CBA device single ended passive partner unspecified no configuration is necessary if the device involved in S7 communication is operated...

Страница 52: ...programs in STEP 7 to handle communication with the conventional devices 3 Then generate the PROFINET CBA components in STEP 7 and enter these in the SIMATIC iMap library 4 Interconnect the PROFINET CBA component in SIMATIC iMap 5 Downloading the user program and configuration data to the S7 400 station with STEP 7 6 Downloading the interconnection information of the process inputs and process out...

Страница 53: ...further information in the file system Please note the following special features when operating IT functions Note The data exchange for productive communication S7 connections SEND RECEIVE connections always has a higher priority than data exchange with the Web browser This can lead to delays in the HTML process control in the Web browser Web Browser To access the HTML pages on the CP 443 1 Advan...

Страница 54: ...ts compared with 6GK7 443 1EX40 0XE0 V2 2 V2 3 S Recording of blocked access attempts in a LOG file in the file system of the CP if IP access protection is activated This is new Functional enhancements compared with 6GK7 443 1EX40 0XE0 V2 1 S Open TCP IP communication is supported S Connection diagnostics with FC AG_CNTRL is supported S Instead of FB88 FB90 is available for the user interface to P...

Страница 55: ...communication performance reaction time and data throughput this is particularly noticeable when working in multicomputing systems The new functionality includes S SNMP agent S IP access protection IP ACL also exists on the 6GK7 443 1EX11 0XE0 as of firmware version V2 3 S IP configuration S Diagnostic buffer extract request S S5 S7 addressing mode also exists on 6GK7 443 1EX11 0XE0 S Memory submo...

Страница 56: ...ig S Removing inserting the CP when the power supply is turned on causes an I O error on the CPU this I O error can only be cleared by turning the power supply for the rack off and on again S The configuration data is stored only on the CPU module replacement possible without PG S Downloading the firmware requires the mode selector to be set to STOP and the power supply must be turned off and on S...

Страница 57: ...443 1 IT It is fully compatible with and taking into account the restrictions described above adapted configuration data can be used to replace the following previous modules S CP 443 1 ISO with order number 6GK7 443 1BX00 0XE0 S CP 443 1 ISO with order number 6GK7 443 1BX01 0XE0 S CP 443 1 TCP with order number 6GK7 443 1EX00 0XE0 S CP 443 1 TCP with order number 6GK7 443 1EX01 0XE0 S CP 443 1 wi...

Страница 58: ...le in the Properties dialog of the Ethernet subnet 3 Save compile and download the configuration data to the CPU or CP again Caution Remember the following points regarding the power supply during installation S When using the CP in the central rack or in a universal rack operating as the central unit the following applies The CP 443 1 Advanced should not be inserted or removed while the power sup...

Страница 59: ...ou will always object the configuration data that were previously on the CP with parameters connections IP address How to Use the Functions You can start the memory reset functions in STEP 7 The CP must be in STOP If you use PROFINET IO the CPU must also be in STOP mode S Clear reset In STEP 7 HW Config with PLC Clear Reset or In STEP 7 NCM Diagnostics with the menu command Operating Mode Clear Re...

Страница 60: ...red MAC address and the retentive parameters The CP is therefore immediately ready for downloads using the IP address Overall this has the following effects Data maintained on the S7 400 CPU Deleted memory area Factory set MAC address Fixed data C PLUG Retentive parameters Flash file system RAM Area Volatile RAM file system ram Non volatile RAM file system sram Battery backed RAM area CPU data Con...

Страница 61: ...area is retained the retentive parameters are deleted Overall this has the following effects Data maintained on the S7 400 CPU Deleted data areas Factory set MAC address Fixed data C PLUG Retentive parameters Flash file system RAM Area Volatile RAM file system ram Non volatile RAM file system sram Battery backed RAM area CPU data Configuration Data Note Please note that the interconnection informa...

Страница 62: ...e CP is configured for automatic detection As soon as you define a configuration manually when configuring the CP with STEP 7 HW Config in the properties dialog of the CP Port Parameters tab the automatic switchover is no longer effective This also applies to the autocrossing mechanism described below Autocrossing Mechanism With the autocrossing mechanism integrated in the switch it is possible to...

Страница 63: ...mple the CP is set to 100 Mbps full duplex a CP connected as partner will set 100 Mbps half duplex Reason Due to the fixed setting no autonegotiation response is possible the connected partner recognizes the 100 Mbps with autosensing but nevertheless remains in half duplex S Recommendation Change individual network settings only over MPI If you modify the LAN settings in the properties dialog of t...

Страница 64: ... the client mode at regular intervals to the NTP server in the subnet LAN Based on the responses of the server the most reliable and most accurate time of day is calculated and the time synchronized on the station in all modules with time of day functionality The advantage of this mode is that time of day synchronization is possible over different subnets The accuracy depends on the quality of the...

Страница 65: ...ted for the CP and it does not therefore forward the time However the internal clock of the CP is also synchronized in this situation when a time of day frame is received from the communication bus or from Industrial Ethernet Synchronization using one of the two modes described here must be configured in STEP 7 in the properties dialog of the CP Time of Day Synchronization tab For more detailed in...

Страница 66: ...s access data of the CPU too often using S7 functions This slows down communication generally and can lead to lack of resources on the CPU if SEND RECEIVE FCs are called in OB1 cyclically effect reduced data throughput or increased reaction time Remedy The recommendations below will help to avoid these situations S Do not call communication blocks cyclically in OB1 Communication should be called t...

Страница 67: ... ignored it is possible that the execution of the job will be aborted with an error and resources could be permanently occupied on the CPU 10 5 2 Use of SFB 54 RALRM in PROFINET IO When using SFB54 the optional fields Vendor ID and Instance ID are not supplied in the data structure for the TINFO parameter bytes 28 to 31 You should remember this when evaluating the data 10 5 3 Programmed Communicat...

Страница 68: ...are version V2 2 Use To allow the user program to exchange data with other TCP IP compliant communication partners STEP 7 provides a UDT for the connection parameter assignment and four FBs S UDT 65 TCON_PAR with the data structure for connection parameter assignment S FB65 TCON for connection establishment S FB66 TDISCON for connection termination S FB63 TSEND for sending data S FB64 TRCV for rec...

Страница 69: ...so depends on the number of configured statically established connections You will obtain appropriate condition codes on the call interface of the FBs Please refer to the documentation of the FBs in the online help and in the documentation on STEP 7 There you will also find examples of parameter settings 10 6 SNMP Agent SNMP Simple Network Management Protocol The CP 443 1 Advanced supports data qu...

Страница 70: ...sContact sysLocation and sysName For security reasons only read access is permitted for all other MIB objects S Traps are not supported by the CP MIB Object Interfaces The Interfaces MIB object provides status information on the CP interfaces with the following assignment Index ifDescr 1 4 Port 1 4 5 Internal CP interface Access Permissions using Community Name The CP uses the following community ...

Страница 71: ...Standard IT Interfaces Preventing Illegal Access With various SIMATIC NET components such as OSMs ESMs a wide range of parameter assignment and diagnostic functions for example Web servers network management are available over open protocols and interfaces The possibility of unauthorized misuse of these open protocols and interfaces by third parties for example to manipulate data cannot be entirel...

Страница 72: ...other purposes in the connection configuration S The following port numbers are used for NTP 65532 local port 65533 local port 65534 local port 65535 local port S The following port numbers are used for other services 20 and 21 TCP FTP local port 25 TCP SMTP local port 80 TCP HTTP local port 102 TCP RFC106 local port 135 UDP RPC DCOM 161 UDP SNMP_REQUEST local port 34964 UDP PN I O local port 10 1...

Страница 73: ...cess protection diagnostic object A LOG file is also created in the file system of the CP that you can view in a WEB browser Compared with the recording made in NCM Diagnostics the LOG file provides space for up to 512 entries You will find the LOG file as an HTML file in the file system of the CP in the following directory S ram security IPLogFile htm Further properties The LOG file is created as...

Страница 74: ...e 4 port switch of the module This LAN cable must provide a PtP connection to the PG PC with which you are downloading Downloading over the existing Ethernet network is not permitted Follow the steps outlined below 1 Set the mode selector of the CP to STOP and turn the power off and on again The STOP LED is lit permanently for approximately 3 seconds Following this the LED combination Ready for st...

Страница 75: ...nload The firmware loader then signals a timeout or negative response from the module being loaded Repeat the download using the factory set MAC address If you cannot start the download again following an aborted attempt you should turn off the entire rack and turn it on again You can then trigger the firmware download again within 10 seconds with the mode selector set to STOP In this case you mus...

Страница 76: ...m Current consumption for battery backed RAM file system sram from battery of power supply module 0 018 mA typical 0 063 mA maximum Power loss 7 25 W Permitted ambient conditions S Operating temperature S Transportation storage temperature S Relative humidity max S Altitude 0 C to 60 C 40 C to 70 C 95 at 25 C up to 2000 m above sea level Design Dimensions module in casing H x W x D mm 290 x 25 x 2...

Отзывы: