
C
Clliin
niitte
ek
k A
Ad
dv
va
an
nttu
us
s
O
Op
pe
erra
atto
orr’’s
s
G
Gu
uiid
de
e
2
25
5
O
O
p
p
e
e
r
r
a
a
t
t
i
i
n
n
g
g
t
t
h
h
e
e
S
S
y
y
s
s
t
t
e
e
m
m
Managing Results
Managing Results
Results are transmitted to the printer and computer as soon
Results are transmitted to the printer and computer as soon as all reagent
as all reagent
areas on the strip are read.
areas on the strip are read. If a record is flagged for
If a record is flagged for a confirmatory report and
a confirmatory report and
Edit flagged results is On, that record is
Edit flagged results is On, that record is not transmitted until after the end-of-
not transmitted until after the end-of-
run reports complete.
run reports complete.
End-of-Run Reports
End-of-Run Reports
The analyzer may display up to 3 end-of-run reports when the run, or a STAT
The analyzer may display up to 3 end-of-run reports when the run, or a STAT
test, is completed. These reports display if you have
test, is completed. These reports display if you have marked any analytes to
marked any analytes to
flag for confirmatory or microscopic tests, and if
flag for confirmatory or microscopic tests, and if Mark positives is On.
Mark positives is On.
To request these reports:
To request these reports:
1.
1. S
Specif
pecify 1 or m
y 1 or more te
ore tests f
sts for the
or the Confi
Confirmato
rmatory Rep
ry Reports A
orts A and B
and B or
or
Microscopy Report.
Microscopy Report.
2.
2. In t
In the S
he Set
etup r
up rou
outi
tine
ne, se
, sele
lect
ct
On
On
for Edit flagged results.
for Edit flagged results.
The Confirmatory and Microscopic Report screens display the
The Confirmatory and Microscopic Report screens display the
SEQ #
SEQ #
and
and
ID
ID
of the record, and the
of the record, and the abbreviation for each positive analyte marked for
abbreviation for each positive analyte marked for
flagging.
flagging.
Up to 5 records may be displayed on 1 screen.
Up to 5 records may be displayed on 1 screen.
3
3.. U
Us
se
e
Move Up
Move Up
and
and
Move Down
Move Down
to view additional records.
to view additional records.
If both the Confirmatory and Microscopic Reports contain records, the
If both the Confirmatory and Microscopic Reports contain records, the
Confirmatory Reports display first.
Confirmatory Reports display first.
4.
4. Edit t
Edit these res
hese result
ults befor
s before exit
e exiting th
ing the Conf
e Confirmat
irmatory Repo
ory Report. Ref
rt. Refer to
er to
Editing
Editing
Results in the Confirmatory Reports
Results in the Confirmatory Reports
‚ p
‚ pag
age
e 25
25..
5
5.. S
Se
elle
ec
ctt
to print a report.
to print a report.
6
6.. S
Se
elle
ec
ctt
Return to Ready/Run
Return to Ready/Run
to exit the report screen.
to exit the report screen.
If an error is
If an error is reported for 1 or more analytes, a
reported for 1 or more analytes, a report displays after the
report displays after the
Confirmatory and Microscopic Reports. This report displays last.
Confirmatory and Microscopic Reports. This report displays last.
7.
7. Re
Rete
test an
st any spe
y speci
cime
mens l
ns lis
iste
ted.
d.
Editing Results in the
Editing Results in the Confirmatory Reports
Confirmatory Reports
Use this procedure to edit the results of
Use this procedure to edit the results of confirmatory testing.
confirmatory testing.
1.
1. Duri
During the e
ng the end of run r
nd of run revie
eview
w, acces
, access the Co
s the Confirm
nfirmatory R
atory Report
eport screen
screens.
s.
2.
2. Sele
Select a r
ct a record
ecord from
from the
the Confi
Confirmat
rmatory Re
ory Report A
port A screen
screen..
The flagged
The flagged positive test results
positive test results display
display..