Information
Base Station System
Technical Description (TED:BSS)
BS-240/241
4.1.3
Parameters of Tower Mounted Amplifier (TMA)
900 MHz Tower Mounted Amplifier
Electrical
System
Specified
Typical
Uplink
RF-band
890- 915 MHz
Return Loss (ANT / BTS port)
> 14 dB
> 15 dB
Return Loss by- pass mode
> 7,7 dB
> 10dB
Nominal gain
25.5 +2/- 2.5 dB at 25˚C (77˚F)
25.5 +3/- 3.5 dB -33˚C to +65˚C
(-27˚F to +149˚F)
25.5 +/- 1 dB at
25˚C (77˚F)
Gain ripple
< +/- 0.5 dB at 25˚C (77˚F)
< +/- 0.8 dB -33˚C to +65˚C
(-27˚F to +149˚F)
Passband ripple, max
< = 0.5 dB
Insertion loss bypass mode, max.
< = 5 dB
max. 3.4 dB
Noise figure, max.
3.6 dB
2.8 dB
Max. input power CW
8 x 15 Watt input TMA
1 dB compression point (CP1)
> = 16.5 dBm (output)
3rd order Intercept Point (IP3) on input
+ 1 dBm
>= 6 dBm
Current consumption
< = 500 mA
< = 400 mA
Downlink
RF- band
935 – 960 MHz
Insertion loss
< = 0.8 dB
< = 0.4 dB
Downlink Return Loss (ANT / BTS port)
> = 18 dB
>= 18.5 dBm
Return Loss (ANT / BTS port) bypass mode > = 18 dB
>= 18.5 dBm
Passive Intermodulation products,
max. @ ANT port
IMD3 and higher
< = -108 dBm
-120 dBm
Passive Intermodulation products,
max. @ BTS port
IMD3 and higher
<= -108 dBm + Gain (Ant- BTS)
-100 dBm
Tab. 4.3
Parameters of 900 MHz Tower Mounted Amplifier