Technical Product Information
January 2005
Binary Input wave AP 261
5WG3 261-3AB11
Technical Manual
wave AP 261, 4 pages
Siemens AG
Automation and Drives Group
Update: http://www.siemens.de/gamma
Siemens AG 2005
Electrical Installation Technology
Subject to change without prior notice
P.O. Box 10 09 53, D-93009 Regensburg
2.20.3.2/2
Electrical safety
•
Pollution degree (according to IEC 60664-1): 2
•
Protection (according to EN 60529): IP 20
•
Overvoltage category (according to IEC 60664-1): III
•
Device complies with EN 60669-2-1 and IEC 60664-1
Electromagnetic compatibility
complies with
EN 301489, EN 300220
Environmental specifications
•
Climatic conditions: EN 50090-2-2
•
Ambient operating temperature: - 5 ... + 45
°
C
•
Storage temperature: - 25 ... + 70
°
C
•
Relative humidity (non-condensing): 5% to 93%
Certification
complies with
- standard
-
radio frequency rf
-
easy mode push button EP
CE norm
complies with the EMC regulations (residential build-
ings),
low voltage regulations and R&TTE regulations:
The CE declaration can be inspected at:
SIEMENS AG
Siemensstraße 10
93055 Regensburg
Installation Instructions
Caution:
•
The device may be used for interior installations and in
dry rooms only.
•
The device may not be opened for warranty reasons.
•
Occasionally the transmission range may be influ-
enced by structural conditions (e.g. reinforced con-
crete) or electric / electronic sources of interference.
•
A
minimum
distance
of 1 m
must
be
maintained
be-
tween the
binary input
wave
and
the
relevant
receivers.
•
Although the radio transmission is carried out in the
safe 868 MHz range, disruptions to the radio transmis-
sion cannot be excluded.
•
This product is not suitable for security applications in
professional alarm systems.
Mounting
It
is
advisable
to
attach
the
radio-controlled sensor to the
fixed
door/window
frame
and
to
attach
the
magnet
to
the
movable
door
or
window. The mounting plate (B2) of the
binary input (B1) as well
as
the
magnet (B3)
can
be
fixed
using
the
supplied
adhesive
strips
or
with
screws
if
nec-
essary. When using the adhesive strips the ground must
be clean and non-greasy. It
should
be
ensured that
the
SIEMENS
markings
on
the
mounting
plate
and
magnet
lie on top of each other as much as possible (Diagram B)
and that the
distance
(gap)
between
the
mounting
plate
and
the
magnet is at least 3 mm but does not exceed
10 mm. With the magnet at this distance from the binary
input, the internal reed contact is closed.
Diagram B
Before clipping the radio-controlled sensor onto the
mounting plate,
the
insulating
strip
(C4)
that
is
inserted
in
the
battery compartment (C1) on the back of the sensor
must be removed and if necessary an external contact
should be connected.
Diagram C
B1
B2
B3
min. 3mm
max. 10mm
C2
C3
C1
C4
C5