This command generates a simple list of available commands.
Enter the
list
command at any time from the Configuration Management
interface to see event buffer messages. The list command has an inter-
nal current sequence number that is set to 1 each time a Configuration
Management login occurs. The list command will show 21 messages
each time it is entered, beginning with the current sequence number. The
current sequence number is updated each time
list
is used. A new cur-
rent sequence number can be entered with the
list
command:
local>
list 10
10 LOG:Port 10: Start probing
09/27
08:14:22.42
11 LOG:User logged in
09/27
08:14:27.00
12 LOG:Port 10: Start link validation
09/27
08:14:29.92
13 LOG:Port 1: Start link validation
09/27
08:14:29.93
14 LOG:Port 10: Link up (this half)
09/27
08:14:33.92
15 LOG:Port 1: Link up (both halves)
09/27
08:14:33.93
16 LOG:Port 4: Start link validation
09/27
08:20:22.52
17 LOG:Port 6: Start link validation
09/27
08:20:22.56
18 LOG:Port 4: Link up (both halves)
09/27
08:20:26.52
19 LOG:Port 6: Link up (this half)
09/27
08:20:26.56
20 LOG:Port 5: Take port off-line
09/27
08:20:54.84
21 LOG:Port 7: Take port off-line
09/27
08:21:10.27
22 LOG:Port 7: Start test mode
09/27
08:21:13.07
23 LOG:Port 1: Link down (no carrier in three polls)
09/27
08:23:23.77
24 LOG:Port 1: Lost carrier
09/27
08:23:23.77
25 LOG:Port 1: Start probing
09/27
08:23:23.77
26 LOG:Port 1: Start link validation
09/27
08:23:46.32
27 LOG:Port 1: Link up (both halves)
09/27
08:23:50.32
28 LOG:Port 7: Stopped test mode
09/27
08:27:43.41
29 LOG:Port 7: Take port off-line
09/27
08:27:43.41
30 LOG:User logged out
09/27
08:34:45.48
31 LOG:User logged in
09/27
08:41:05.05