Smart Cart Overview 

3

System Overview 

10

Control Panel 

16

Touch Screen 

20

Patient Exam 

22

2D 26
Doppler 30
Annotation / Body Marker 

36

Analysis 38
Review 42
Reports 46
Export / Import 

50

2

Содержание ACUSON P500

Страница 1: ...ACUSON P500 Ultrasound System FROSK Edition Quick Reference Guide siemens com ultrasound ...

Страница 2: ...Contents Smart Cart Overview 3 System Overview 10 Control Panel 16 Touch Screen 20 Patient Exam 22 2D 26 Doppler 30 Annotation Body Marker 36 Analysis 38 Review 42 Reports 46 Export Import 50 2 ...

Страница 3: ...leaver and push down or pull up to adjust height Smart Cart Height Adjustment Smart Cart Overview System Overview Control Panel Touch Screen Patient Exam 2D Doppler Annotation Body Marker Analysis Review Reports Export Import 3 ...

Страница 4: ...Locking and Unlocking the Wheels 1 There are two lock positions 2 Press large tab down to lock 3 Lift large tab up to unlock Lock Unlock Smart Cart Overview 4 ...

Страница 5: ... To lock place the lever in the up position 4 Connecting transducers to the MTM follows the same process Attaching the Multiple Transducer Module MTM 2 1 4 4 4 Control Panel Touch Screen Patient Exam 2D Doppler Analysis Review Reports Export Import Annotation Body Marker Smart Cart Overview System Overview 5 ...

Страница 6: ...ach side of the Smart Cart 2 When transporting the cart with transducers place the cables through the provided hook to prevent damage TIP Instructions for removal of the ACUSON P500 system from the cart are located by the back handle of the Smart Cart Smart Cart Overview 6 ...

Страница 7: ...heral Power Peripheral USB LAN DC Out Located on the upper back of the Smart Cart Located on the lower back of the Smart Cart Smart Cart Overview Control Panel Touch Screen Patient Exam 2D Doppler Analysis Review Reports Export Import Annotation Body Marker System Overview 7 ...

Страница 8: ... the back of the holder Pull the holder towards the floor to remove Clean with mild detergent Insert into transducer holder pressing upward until you hear a click Cleaning the Smart Cart Use only approved disinfectants For a complete list see the ACUSON P500 system Help menu 8 ...

Страница 9: ...Control Panel Touch Screen Patient Exam 2D Doppler Analysis Review Reports Export Import Annotation Body Marker Smart Cart Overview System Overview 9 ...

Страница 10: ...cer 1 Ensure lever lock is in the down unlocked position 2 Align the connector and press into the transducer port 3 Place the lock in the up position 4 Once the system detects the transducer the name displays to the right of the image 10 ...

Страница 11: ...ction 2 High Definition Multimedia Interface HDMI connection 3 Universal Serial Bus USB ports 4 Audio Jack Headphones Smart Cart Overview Control Panel Touch Screen Patient Exam 2D Doppler Analysis Review Reports Export Import Annotation Body Marker System Overview 11 ...

Страница 12: ...W spectral Doppler Mode Depth Zoom Button Press to start or end Zoom Dial Adjusts the scanning depth or amount of magnification of the image Angle Button Changes the PW Doppler angle in 60 degree increments Dial Changes the PW Doppler angle in 1 degree increments Invert Moves the spectral tracing or color Doppler to above or below the baseline Starts or stops Tissue Equalization Technology TEC pro...

Страница 13: ... modes Baseline Increases or decreases the baseline in the pulsed and continuous wave and color Doppler modes Freeze pauses or resumes scanning User programmable key for ending a study Activates the Body Marker menus available for the active preset Activates the annotation menus for the active preset Smart Cart Overview Control Panel Touch Screen Patient Exam 2D Doppler Analysis Review Reports Exp...

Страница 14: ...ad and slide controls are free of gel Dry surface with lint free cloth Monitor Moisten clean lint free cloth with mild detergent or water Wipe monitor to clean Dry surface with lint free cloth Cleaning the ACUSON P500 System Use only approved disinfectants For a complete list see the ACUSON P500 system Help menu System Overview 14 ...

Страница 15: ...Smart Cart Overview Touch Screen Patient Exam 2D Doppler Analysis Review Reports Export Import Annotation Body Marker Control Panel System Overview 15 ...

Страница 16: ... Soft Key buttons 3 DGC 4 Depth Zoom 5 Measure 6 Clip Store 7 Print Store 1 8 Print Store 2 9 Freeze 10 TEQ 11 Touch pad keys 12 Touch pad 13 2D push rotary gain 14 Color push rotary gain 15 M mode push rotary gain 1 2 3 4 5 6 7 9 10 11 12 13 14 15 8 16 ...

Страница 17: ...kflow Controls 24 Arrow 25 Alternate keyboard 26 End Exam 27 Clear Screen 28 Text Annotation 29 Body Marker 30 Alphanumeric keyboard 16 18 21 19 22 23 24 27 25 28 26 29 30 20 17 Smart Cart Overview Patient Exam 2D Doppler Analysis Review Reports Export Import Annotation Body Marker Control Panel Touch Screen System Overview 17 ...

Страница 18: ...n page Review Opens the page to review an exam create a slide show or teaching file Report Opens the report screen to view the results and close the study Browser Allows viewing of the patient studies start a new exam restart an exam and delete studies Config Opens menus for user customization of the system Help Opens the user manual menu for the Help menu 18 ...

Страница 19: ...ing Slide Moves or changes on screen functions such as a caliper or color box Scrolls through a list i e thumbnails Pinch and spread Changes the size of an on screen function i e Doppler gate Touch Pad Smart Cart Overview 2D Doppler Analysis Review Reports Export Import Annotation Body Marker Patient Exam Control Panel Touch Screen System Overview 19 ...

Страница 20: ...rence image 2D Physio Settings Biopsy Steer L R Flip L U D Flip U Steer PW xxxxxxxxxxx xx_xx_xxxx_xx_xx_xx x ACUSON xxxx xxxx xxxxxxxxxxxx VF13 5 Small Parts ธ Tx Power 100 MA 0 59 ASC 2 DTCE Low Dyn R 75 dB THI 8 9 MHz 26 dB 45 tps Dual Focus Position MultiHertz 8 9 MHz Update Position Position Dyn R 76 dB THI On Gate 0 Image Presets Gen Edge OTCE Adv SieCl Map Tint Tx Power Focus Min Parallel Tr...

Страница 21: ...Smart Cart Overview 2D Doppler Analysis Review Reports Export Import Annotation Body Marker Patient Exam Control Panel Touch Screen System Overview 21 ...

Страница 22: ...how Files 2 Source Media 3 Search Criteria 4 Search 5 Clear Search 6 Study List 7 Send 8 Output Device 9 Delete 10 Export Import 11 Navigation menu 1 2 6 3 4 5 7 9 10 11 8 Browser Patient Exam Patient Browser 22 ...

Страница 23: ...x You may start the exam without registering a patient and then update the patient information at any time before ending the exam TIP TIP Patient Data Smart Cart Overview Control Panel Touch Screen Patient Exam 2D Doppler Analysis Review Reports Export Import Annotation Body Marker System Overview 23 ...

Страница 24: ...ient Data Edit data Click OK Patient Exam TIP TIP To change the patient data entry fields select short or long form on the General 2 Configuration page You can start an new exam or restart an exam from the Patient Browser page Patient Data Cont 24 ...

Страница 25: ...Smart Cart Overview Control Panel Touch Screen Doppler Analysis Review Reports Export Import Annotation Body Marker Patient Exam 2D System Overview 25 ...

Страница 26: ...f displayed gray shades Map Soft Key Changes gray scale image based on the intensity of the signal Tint Soft Key Display of a color overlay applied to the gray scale image L R Flip Soft Key Flips the left side of the image to the right and vice versa U D Flip Soft Key Flips the top of the image to the bottom and vice versa Zoom Pan Button Touch Pad Zoom enlarges the image and Pan allows movement t...

Страница 27: ...Biopsy Soft Key Activates biopsy angles Depth Zoom push rotary button Distance of the image into the body DGC Slide Pots Adjustment of brightness to adjust for dark areas on the image due to sound absorption in the tissue Dual Soft Key Displays two images in a side by side format Smart Cart Overview Control Panel Touch Screen Patient Exam 2D Doppler Analysis Review Reports Export Import Annotation...

Страница 28: ...the number of focal zones Image Presets Soft Key Allows selection of Res Gen and Detail to adjust for patient body type MultiHertz Multiple Frequency Imaging Soft Key Allows the user to select frequencies in both fundamental and harmonic modes while performing real time 2D imaging Overall Gain rotary button Adjusts the overall brightness of the image Persist Soft Key Number of frames averaged to f...

Страница 29: ...ation method that uses returning high frequencies to create the image TEQ Ultrasound Technology Button Continuously optimizes the overall gain and DGC Press once to activate twice to deactivate Tx Power Soft Key Allows adjustment of the power setting Trapezoid Soft Key Increases the FOV for a linear transducer resulting in a trapezoidal shaped image Smart Cart Overview Control Panel Touch Screen P...

Страница 30: ...line Map Soft Key Changes spectral Doppler tracing gray scale based on the intensity of the signal Sweep Soft Key Adjusts the speed of the spectral Doppler tracing Tint Soft Key Display of a color overlay applied to the spectral Doppler tracing PW Press Rotary button Button Enters Exits PW Doppler Rotary Increases Decreases the PW spectral tracing gain Pulsed wave Doppler controls that can be adju...

Страница 31: ...justs the spatial averaging for flow Priority Soft Key Adjusts the priority of the resolution of color Doppler compared to 2D Increasing improves the color Doppler display and decreasing improves the 2D display Controls shared by Color Doppler Energy CDE and Color Doppler Velocity CDV modes Smart Cart Overview Control Panel Touch Screen Patient Exam 2D Doppler Analysis Review Reports Export Import...

Страница 32: ...ses the Color gain CDE Soft Key Enters Exits Color Doppler Energy Power Doppler mode CDV Soft Key Enters Exits Color Velocity Directional Doppler CW Soft Key Enters Exits continuous wave Doppler Note Must have a phased array transducer attached and have PW active Doppler Color Doppler Controls 32 ...

Страница 33: ...e size of the sample volume gate Simult Soft Key Displays both the 2D image and spectral tracing in real time Steer Changes the D line angle Update Rate Soft Key Adjusts how often the 2D reference image updates during duplex imaging Volume Soft Key Increases or decreases the audio of the spectral Doppler signal Controls used during pulsed wave PW Doppler real time imaging Smart Cart Overview Contr...

Страница 34: ...ntensity of the signal Sweep Soft Key Adjusts the speed of the spectral Doppler tracing Tint Soft Key Display of a color overlay applied to the gray scale image or spectral tracing Controls that can be adjusted during real time imaging or on the frozen image on the pulsed or continuous wave tracing Spectral Doppler Shared Image Controls TIP To bypass the Doppler Cursor Mode or select Frequency or ...

Страница 35: ...djusts the pulse repetition period PRF of the active mode Steer Soft Key Angles the D line or color box to the left or right Real time only controls shared by PW continuous wave CDE and CDV modes TIP You can customize the ACUSON P500 System Doppler behavior on the Exam tab of the Configuration menus Smart Cart Overview Control Panel Touch Screen Patient Exam 2D Doppler Analysis Review Reports Expo...

Страница 36: ...a line of text Delete Word Removes the last word typed Hide Show Text Removes or displays text Home Area selected for the text to begin or cursor to return Set Home Position Allows selection of home position for the text cursor Feature Function Change Body Marker Changes the displayed body marker 36 ...

Страница 37: ...Smart Cart Overview Control Panel Touch Screen Patient Exam 2D Doppler Analysis Review Reports Export Import Annotation Body Marker System Overview 37 ...

Страница 38: ...Press the Auto Stat soft key on the upper left of the monitor 3 Select Above Below or Both Doppler Auto Trace Analysis TIP Auto Stat functions on a real time or frozen image Auto Stat measurements do not enter into the exam report 38 ...

Страница 39: ...ements Touch Pad Move anchor and edit caliper functions Delete Removes one measurement starting with the last one performed Delete all Removes all calipers Smart Cart Overview Control Panel Touch Screen Patient Exam 2D Doppler Annota tion Body Marker Analysis Review Reports Export Import System Overview 39 ...

Страница 40: ...e touch pad to position the caliper and press Set or tap the touch pad to anchor 4 Position the first caliper and press Set 5 Use the Edit button to toggle between calipers 6 Press Set to anchor the second caliper The calipers and active measurements display green TIP General Measurements 40 ...

Страница 41: ...oggle between calipers 6 Press Set to anchor the second caliper 7 Press Print Store to enter the measurement into the patient report TIP You can also measure and enter information into the patient report from an image in Review This function only works with an open exam Smart Cart Overview Control Panel Touch Screen Patient Exam 2D Doppler Analysis Review Reports Export Import Annotation Body Mark...

Страница 42: ...view Opens review on an exam in progress Browser Opens a menu that allows selection of a saved exam Return to Imaging Returns to real time imaging Select Deselect Review touch pad functions Play Pause Cine touch pad functions 42 ...

Страница 43: ...t frame 9 Set End Marker 10 Frame Frame total 11 Last frame 12 Save Cine review functions available during the exam and in Review 1 2 3 4 5 6 7 8 9 10 11 12 Smart Cart Overview Control Panel Touch Screen Patient Exam 2D Doppler Analysis Review Reports Export Import Annotation Body Marker System Overview 43 ...

Страница 44: ...eating a Slide Show 1 From an active exam press Review 2 From a saved exam press Browser 3 Tap images for the slide show 4 Tap Slide Show 5 You can Stop or Start the slide show 6 Tap Exit to return to imaging 44 ...

Страница 45: ...er a name 6 Click on New Adding Images to a Teaching File 1 From an active exam press Review 2 From a saved exam press Browser 3 Select the teaching file 4 Click on Append 5 Add images to the teaching file Smart Cart Overview Control Panel Touch Screen Patient Exam 2D Doppler Analysis Review Reports Export Import Annotation Body Marker System Overview 45 ...

Страница 46: ...Reports Only entered exam specific measurements appear in the report Feature Function Report Enters Exits Report page Scrolling Touch pad allows scrolling through reports sections 46 ...

Страница 47: ...ointer to draw 6 Select Delete to erase the last area 7 Select Delete All to erase all drawn areas TIP Drawing function is only available in the CV exam Smart Cart Overview Control Panel Touch Screen Patient Exam 2D Doppler Analysis Review Reports Export Import Annotation Body Marker System Overview 47 ...

Страница 48: ... to the Report 1 Select Results 2 Select either 2D measurements or 3D measurements 3 Select the value for editing 4 Enter new value 1 Select Summary 2 Add comments in the text box 3 Select Load Comments to add preconfigured comments 48 ...

Страница 49: ...ting an Image in the Report 1 Select image 2 Press Set Smart Cart Overview Control Panel Touch Screen Patient Exam 2D Doppler Analysis Review Reports Export Import Annotation Body Marker System Overview 49 ...

Страница 50: ...elect the exam 3 Select the Output Device 4 Click Send 5 The study appears in the Queue Import a Study 1 Press Browser 2 Select the Source Media 3 Select exams for import 4 Exams appear at D Local Disk You can only import a study in DICOM format 50 ...

Страница 51: ...t 1 Press Browser or Review 2 Select patient exam 3 Select images 4 Click Export 5 Select the format type 6 Select export destination 7 Click Export Smart Cart Overview Control Panel Touch Screen Patient Exam 2D Doppler Analysis Review Reports Export Import Annotation Body Marker System Overview 51 ...

Страница 52: ...s of Siemens Medical Solutions USA Inc The products features mentioned in this document may not be commercially available in all countries Due to regulatory reasons their future availability cannot be guaranteed Please contact your local Siemens organization for further details Images used in this guide are for educational purposes only They have been modified or compressed and may not reflect the...