AC75 Hardware Interface Description
Strictly confidential / Preliminary
s
AC75_HD_V00.202
Page 83 of 120
27.04.2006
5.2 Operating
Temperatures
Table 21: Board temperature
Parameter
Min
Typ
Max
Unit
Operating temperature range
-30
+85
°C
Automatic shutdown
Temperature measured on AC75 board
Temperature measured at battery NTC
-30
-20
---
---
+90
+60
°C
Table 22: Ambient temperature according to IEC 60068-2 (without forced air circulation)
Parameter
Min
Typ
Max
Unit
Operating temperature range
-30
+25
+75
°C
Restricted operation
---
+75
to
+85
°C
Table 23: Charging temperature
Parameter
Min
Typ
Max
Unit
Battery temperature for software controlled fast charging
(measured at battery NTC)
0 ---
+45
°C
Note:
•
See
3.3.4 for further information about the NTCs for on-board and battery
temperature measurement, automatic thermal shutdown and alert messages.
•
When data are transmitted over EGPRS or GPRS the AC75 automatically reverts to a
lower Multislot Class if the temperature increases to the limit specified for normal
operation and, vice versa, returns to the higher Multislot Class if the temperature is back
to normal. For details see Chapter 3.4 “Automatic EGPRS/GPRS Multislot Class
Change”.
5
Due to temperature measurement uncertainty, a tolerance on the stated shutdown thresholds may occur. The
possible deviation is in the range of ± 3°C at the overtemperature limit and ± 5°C at the undertemperature limit.
6
Restricted operation allows normal mode speech calls or data transmission for limited time until automatic
thermal shutdown takes effect. The duration of emergency calls is unlimited because automatic thermal
shutdown is deferred until hang up.