AC75 Hardware Interface Description
Strictly confidential / Preliminary
s
AC75_HD_V00.202
Page 101 of 120
27.04.2006
5.8 Air
Interface
Test conditions: All measurements have been performed at T
amb
= 25°C, V
BATT+ nom
= 4.0V.
The reference points used on AC75 are the BATT+ and GND contacts (test points are shown
in Figure 4).
Table 34: Air Interface
Parameter
Min
Typ
Max
Unit
GSM
850
824
849 MHz
E-GSM
900 880
915 MHz
GSM
1800
1710
1785 MHz
Frequency range
Uplink (MS
→
BTS)
GSM
1900
1850
1910 MHz
GSM
850
869
894 MHz
E-GSM
900 925
960 MHz
GSM
1800
1805
1880 MHz
Frequency range
Downlink (BTS
→
MS)
GSM
1900
1930
1990 MHz
GSM
850
31 33 35 dBm
E-GSM 900
31 33 35 dBm
GSM 1800
28 30 32 dBm
RF power @ ARP with 50
Ω
load
GSM
1900 28 30 32 dBm
GSM
850 124
E-GSM
900
174
GSM
1800 374
Number of carriers
GSM
1900 299
GSM
850 45
MHz
E-GSM
900
45
MHz
GSM
1800 95
MHz
Duplex spacing
GSM
1900 80
MHz
Carrier
spacing
200
kHz
Multiplex, Duplex
TDMA / FDMA, FDD
Time slots per TDMA frame
8
Frame
duration
4.615
ms
Time slot duration
577
µs
Modulation GMSK
GSM 850
-102
-108
dBm
E-GSM 900
-102
-108
dBm
GSM 1800
-102
-107
dBm
Receiver input sensitivity @ ARP
BER Class II < 2.4% (static input level)
GSM 1900
-102
-107
dBm
15
Power control level PCL 5
16