Introduction
1.2 Safety Notes
FUT1010 IP65 NEMA 4X & IP66 NEMA 7 Liquid Quick Start
10
Operating Instructions, 1/2013, A5E02639182-AC
derstand and follow all safety instruction on the electronic media provided. This
res as stated below and must be installed
according to the 1010-464 installation drawing provided on the media. Failure to install the
rescribed manner will result in unsafe operation. Follow all regional safety
ATEX installation
Read, un
equipment is rated for use in explosive atmosphe
equipment in the p
laws when operating this equipment. When properly installed the equipment meets the
following ATEX ratings as stated in EC-Type Examination Certificate KEMA03ATEX1134
Transmitter Markings and Explanations
●
II (1) G [Ex ia] IIC– Transmitter located in the non-hazardous area with intrinsically
safe circuits of category Ex ia, which can be connected to Category 1 Sensors for use i
n
potentially explosive atmosphere containing gases
●
II 3 (1) G Ex nC [ia] IIC T5 (Tamb = 0° To + 60°C) – Category 3 Transmitter located in
Zo
,
●
ne 2 potentially explosive atmosphere with intrinsically safe circuits of category Ex ia
which can be connected to Category 1 Sensors in Zone 0 for use in potentially explosive
atmosphere containing gases
II 2 (1) G Ex d [ia IIC] IIB T5 (Tamb = 0° To + 50°C) – Category 2 Transmitter located
in Zone 1 potentially explosive atmosphere with intrinsically safe circuits of category Ex
ia, which can be connected to Category 1 Sensors for use in potentially explosive
atmosphere containing gases
●
IP66 – Ingress protection against solid bodies, rating of dust-tight and against liquid,
rating of heavy seas
Sensor Markings and Explanations
●
II 1 G Ex ia IIC T5 – Category 1 Sensors located in Zone 0 potentially explosive
atmosphere with intrinsically safe circuits of category Ex ia for use in potentially exp
atmosphere containing gases
losive