4.
Type the card’s IP address into the address bar of Internet Explorer. The factory
default IP address for the interface card is
10.10.10.10
WARNING:
When browsing to WiMag Interface Cards using Internet Explorer,
IE
must be set to Compatibility Mode
for configuration changes to be accepted
correctly (see section 16.4.1). Alternatively, use Firefox to complete the following
instructions.
a.
If you are not able to connect to the card, this could be because the card’s
IP address may have been changed. To return the IP address to the factory
default (10.10.10.10) power cycle the card with the ‘configuration link’
removed.
Figure 32 : Loop Detector Replacement Card Configuration Link
5.
Set the ‘new’ IP address of the interface card, as per the configuration sheet.
6.
If required, a ‘Username’ and ‘Password’ may be set. This will be indicated on the
configuration sheet. However, it is generally recommended that username and
password are kept blank.