Binary input device N 262E01 

5WG1 262-1EB01

 

8x potential-free contacts  

Technical Manual 

N 262E01, 4 pages 

Siemens AG

 

 

 

Infrastructure & Cities Sector, Building Technologies   

Update: http://www.siemens.de/gamma 

 Siemens AG 2013 

Control Products and Systems 

 

Subject to change without further notice 

P.O. Box 10 09 53, D-93009 Regensburg 

2.7.3.2/4 
 

Attaching the bus terminal (Figure 3) 
Insert the bus terminal into the guide slot and press the 
bus terminal (D2) backwards until it reaches the stop po-
sition. 
 

D1

D2

D2

D2.4

D2

D2.4

5 mm

D2.1 D2.2

2

D2.3

 

D

   

 

Figure 3: Attaching / removing the bus terminal 

 
Mounting the insulating cap 
If the device is to be mounted on a DIN rail without a 
data rail, then the contact system must be covered using 
the supplied insulating cap.  
 
Removing the locating clamp  (Figure 4) 

-

 

The locating clamp (E3) encloses the contact system 

(E2) on the rear of the device (E1).  

-

 

Insert the screwdriver between the DIN rail mounted 

device (E1) and the locating clamp (E3) and remove 
the clamp.  

 

Clipping on the insulating cap (Figure 4) 

-

 

Place the insulating cap (E4) on the contact system and  

press so that it snaps into place.  

 
 
 
 

 

 

 

Figure 4: Covering the contact system 

Dimension drawing 

 
Dimensions in mm. 
 

 

b

 

9

0

 

44

 

55

 

4

5

 

 

 
b = 6 module units 
 
1 module unit (MU) = 18 mm 
 
 
 

General notes 

 

 

The operating instructions must be handed over to the 
client. 

 

Any faulty device is to be sent together with a return de-
livery note of the local Siemens office. 

 

If you have further questions concerning the product 
please contact our technical support. 

Technical Support 

 

+49 (911) 895-7222 

  

+49 (911) 895-7223 

 

[email protected] 

www.siemens.de/automation/support-request  

 

E3

 

E1

 

E2

 

E2

 

E4  E1 

Содержание 262E01

Страница 1: ...nnected contact is open LED is off or closed LED is illuminated The N 262E01 has an integrated 230 V power supply in order to supply the electronics This power supply en ables the generation of the voltage pulses for checking the switching statuses and for displaying them via the LEDs even when there is no bus voltage present Note The device is without function after the application program has be...

Страница 2: ...age and displaying normal mode addressing mode 1 green LED for displaying the 230 V operating voltage 1 red LED per binary input for status display LED ON contact is closed Inputs 8 inputs potential free with basic insulation 250 V against each other and against the EIB Detection of the switching status of a floating contact connected to an input by means of voltage pulses gen erated by the device...

Страница 3: ...conductor and neutral conductor N for power supply of the electronics A7 LED for displaying the operating voltage Installation and wiring General description The DIN rail mounted device in N system dimensions width 6 module units can be inserted in N system dis tribution boards surface or flush mounted and wher ever DIN rails according to EN 60715 TH35 7 5 are pre sent Installing the DIN rail moun...

Страница 4: ...ct system must be covered using the supplied insulating cap Removing the locating clamp Figure 4 The locating clamp E3 encloses the contact system E2 on the rear of the device E1 Insert the screwdriver between the DIN rail mounted device E1 and the locating clamp E3 and remove the clamp Clipping on the insulating cap Figure 4 Place the insulating cap E4 on the contact system and press so that it s...