Site Wiring Requirements
Description
The type of wiring is dependent upon the site requirements:
•
CE (Conformite Europeene) Certified Areas
•
NEC Division 2 or Non-Hazardous Areas
•
Cenelec Zone 1 or Zone 2 Areas
•
Rack Mounting Non-Hazardous Area
AC Mains Wiring
The installation should have a power disconnect external to the
enclosure.
No voltage dependent selections need to be made on the power supply,
as it has a universal input.
See Page 11, CE Installations.
CE Installations
Use Metal Conduit wiring method.
NEC Div 1, Div 2 or Non
Rated Areas
Conductor type: Power cable sized for circuit protection chosen.
Use Cable Gland wiring method:
Cenelec Zone 1 or Zone 2
Rated Areas
Conductor type: Power cable sized for circuit protection chosen, and
must be shielded.
Use Metal Conduit wiring method.
Non Rated Areas or Rack
Mounting
Conductor type: Power cable sized for circuit protection chosen.
2000592-001
Installation
•
7