Transport, assembly, and connection
3.2 Assembly
A5E00215731A AD
24
Siemens AG Operating Instructions 2.02 1PL618
1.
Remove the screw plugs or plastic plugs regularly to drain off the condensation water.
2.
Replace the plugs afterwards.
NOTICE
Degree of protection
Nominally the degree of protection of the machine is reduced to IP44 by removing the
plastic plug or screw plug.
[ID 1079.02]
3.2
Assembly
3.2.1
Installation
Instructions relevant to safety
CAUTION
The enclosure components of electric motors can become very hot (possibly > 100 °C). Do
not touch enclosure components while the motor is running or immediately after it has been
running.
CAUTION
When positioning temperature-sensitive components (wires etc.), make sure that they are
not in contact with the motor enclosure.
NOTICE
Note also the technical specifications on the rating plates on the motor enclosure.
Cooling conditions in general
●
In the case of motors that are cooled by the ambient air, the cooling air must be able to
flow unimpeded to and from the motors. Hot discharged air must not be reinducted (see
also "Cooling").
Cooling conditions for motors with pipe connection
Motors that are configured to allow pipes to be connected and/or for operation with a
separately driven fan must have pipes and a fan of suitable type and dimensioning mounted
and connected to them.
Содержание 1PL618 Series
Страница 1: ...Operating Instructions Edition 03 2008 Three phase induction motor AC COMPACT DRIVES Type 1PL618 ...
Страница 2: ...18 03 2008 13 20 ...
Страница 8: ......
Страница 16: ......
Страница 40: ......
Страница 48: ......
Страница 66: ......
Страница 70: ......
Страница 74: ......
Страница 76: ......
Страница 77: ......
Страница 78: ......
Страница 79: ...AB U151 Herstellererklärung AB U161 Konformitätserklärung ...
Страница 80: ......