Document No. 540-743 

Installation Instructions  

September 10, 2009 

4.  Pull the cable through the required mounting 

hardware in the order shown. 

MEC0045R1

49
50
51
52

AI21

AI22

AI23

AI24

41
42
43
44
45
46
47
48

+

-

+

-

+

-

+

-

AI17

AI18

AI19

AI20

33
34
35
36
37
38
39
40

+

-

+

-

+

-

+

-

DI5

DI6

DI7

DI8

9

10

11
12
13
14
15
16

DI1

DI2

DI3

DI4

1
2
3
4
5
6
7
8

SHIELD

53
54
55
56

24 VDC

 SENSOR

SUPPLY

SIG 1

COM 1

DI

SIG 2

5      COM2*

4          RTD

3      COM 1

2    LCDPR*

1    OVRRD*

6     SETPT*

SENSOR

TERMINAL BLOCK

COM 2

24 VDC+

 

 

* Optional feature 
NOTE: 1.  Some terminal blocks have only four terminal points. 
 

2.  Not all wires are used with all sensor models. 

 

3.  COM2 is the return signal path for the setpoint option. 

 

4.  Wiring configuration is only an example and can differ 

 

 

depending on application.

 

Figure 8.  Electrical Box and Rough-in Mounting, 

Typical. 

 

Figure 7.  MEC Wiring. (Wiring to Full-featured 

Sensor 544-780). 

5.  Install the two sensor mounting screws provided 

but do not tighten. 

Electrical Box and Rough-in 
Mounting, Typical 

6.  Mount the sensor base plate on the wall, noting 

the "UP" arrow on the stabilizer plate: 

a.  Level the sensor base plate for appearance 

only. 

1.  If a locator is attached to the rough-in device, 

remove the locator by removing the two screws 
and lightly rocking the locator to pull it free. 

b.  Tighten the two mounting screws to the 

sensor base plate. 

2.  Untie the twist tie and pull about three inches 

(75 mm) of the sensor cable into the space. 

CAUTION: 

 

Over-tightening may cause the sensor 
base plate to crack or bend. 

3.  If you have a single-sensor electrical box, install 

the electrical box adapter plate. See Figure 8. 

If you have a double-sensor electrical box, 
install the required mounting plate(s). 

If you use a universal adapter kit for a retrofit 
job, install the multi-slotted plate in place of the 
electrical box adapter plate. See Figure 8. 

7. Continue 

with 

Drywall Mounting (No Rough-in, 

Typical), 

Steps 7 through 13. 

The installation is now complete. 

 

 

 

Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and 
models as design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective 
owners.

 

© 2009 Siemens Building Technologies, Inc. 

 

Siemens Building Technologies, Inc.  

Industry Sector 
1000 Deerfield Parkway 
Buffalo Grove, IL  60089-4513 
U.S.A. 

Your feedback is important to us. If you have 
comments about this document, please send them 
to 

[email protected]

 

 

Document No. 540-743 

Printed in the U.S.A. 

Page 5

 

of

 

5

 

Содержание 1000 series

Страница 1: ...le where applicable and sensor color C C F F A desert beige B white e g 544 770FA for F desert beige Warning Caution Notations WARNING Personal injury loss of life may occur if a procedure is not performed as specified CAUTION Equipment damage or loss of data may occur if you do not follow procedure as specified Item Number 540 743 2 Rev DA Figure 1 Room Temperature Sensor Showing All Optional Fea...

Страница 2: ... 9 cm 155 252P25 TB 238 536 666 Mounting Strap standard light switch plate field supplied to mount sensor on 2 4 electrical box 540 040 540 237 544 782 Single Adapter Base Mounting Kit 2 4 boxes all single sensor installations on walls with oversized holes paint lines etc that need to be covered and on exterior brick cement type walls Kit includes Electrical Box Adapter Plate Assembly 192 495 Adap...

Страница 3: ...nting holes 3 Cut a 1 inch 25 mm center hole with a hole saw 4 If using screws to attach the sensor insert two plastic wall anchors 5 Pull about three inches 75 mm of the cable through the mounting hardware in the order shown See Figure 2 Figure 2 Drywall Mounting No Rough in Typical 6 Mount the sensor base plate on the wall noting the UP arrow on the stabilizer plate a Install either the two moun...

Страница 4: ...1 Tighten the sensor front retaining screw See Figure 2 12 Terminate the other end of the wires either a at the MBC RBC module terminal block s Figure 5 or b at the appropriate UC terminal blocks Figure 6 The installation is now complete Terminating the Cable Wires NOTE 1 All connections for one sensor must be terminated in the same cabinet whether MBC RBC MEC or UC 2 Unitary Controller installati...

Страница 5: ... the locator by removing the two screws and lightly rocking the locator to pull it free b Tighten the two mounting screws to the sensor base plate 2 Untie the twist tie and pull about three inches 75 mm of the sensor cable into the space CAUTION Over tightening may cause the sensor base plate to crack or bend 3 If you have a single sensor electrical box install the electrical box adapter plate See...

Отзывы: