background image

Introduction

5

04.2016

KFV

1.4 

Care and service instructions

•  Regular annual maintenance should be carried out to ensure that all movable components 

are functioning correctly and are lubricated with non-corroding and non-resinous grease.

•  Never use cleaning agents that are aggressive or contain solvents, as these may damage 

the surface of the components. 

•  Both the contractor and the user must be trained in the operation and maintenance of the 

multi-point lock.

1.5 

Installation conditions and requirements

•  Local building laws and regulations must be observed before and during door installation 

in addition to the following requirements and conditions:

•  Observe the milling dimensions
•  Position the frame parts according to the specifications, observing the horizontal and 

vertical adjustment accurately.

•  Before installing the multi-point lock, check the dimensional accuracy of the door and 

the door frame. The multi-point lock must not be installed if the door and/or the frame is 
warped and/or damaged.

•  Install the multi-point lock and accessories according to our assembly instructions. Use the 

clamp included in the delivery supplied for assembly.

•  Remove any splinters from the lock mortise after milling.
•  Once the lock is installed, do not perform mechanical work on the door (such as drilling or 

milling). Do not drill into or through the main lock under any circumstances.

•  Observe the specified positions and sizes when drilling the holes. 
•  Follow the hardware manufacturer's instructions when drilling the holes for the operating 

handle/hardware.

•  Install hardware components and cylinder flush without overtightening the screws or 

screwing them in at an angle.

•  Fasten handle set by hand only and do not use force when installing the spindle.
•  Keep the distance between the secondary sash and frame parts: 

 

  

 

 

For 1-leaf doors: 2 to 6 mm 

  

 

 

For 2-leaf doors: 4 to 6 mm

•  Operating elements should not impede each other.
•  Check that any existing block setting is packed correctly.
•  Surface treatment of the door and door frame must take place before the multi-point lock 

is installed. A subsequent surface treatment can reduce the functional capacity of the 
multi-point lock.

•  Use only acid-free neutral-cure sealants to prevent corrosion of components and/or the door.

1.5.4 

Dimensions

All measurements are given in mm.

Содержание KFV AS3500

Страница 1: ...S C H E N G L I S H F R A N A I S E S PA O L I TA L I A N O N E D E R L A N D S E S K P O L S K I Assembly instructions AS3500 Multi point lock Window systems Door systems Comfort systems ASSEMBLY IN...

Страница 2: ......

Страница 3: ...ning the latch optional 11 2 4 Installing the A opener optional 12 2 5 Installing the door arrester or daytime release optional 13 2 6 Screwing on the multi point lock 15 2 7 Cutting the door frame 16...

Страница 4: ...frame parts with Q adjustment may be used 1 2 3 Transport Always transport the multi point lock in a vertical position whether uninstalled or installed in the door leaf Do not place the multi point lo...

Страница 5: ...ccording to our assembly instructions Use the clamp included in the delivery supplied for assembly Remove any splinters from the lock mortise after milling Once the lock is installed do not perform me...

Страница 6: ...ns and symbols 6 See note on page 17 for transport when installed in an element This symbol indicates that you should read information given at the relevant point of the instructions The number in the...

Страница 7: ...20 290 130 B003 2400 760 980 1020 270 130 B039 1700 760 355 952 263 62 B041 1700 760 605 952 13 62 B166 1855 760 730 952 43 62 B253 2170 760 980 952 108 62 B296 2170 760 355 1020 665 130 B298 2170 760...

Страница 8: ...steel frame parts Material number Material description Contents pieces 3489830 MAGNETIC TRIGGER 3500 Q S1 VE2 2 3489831 MAGNETIC TRIGGER 3500 Q S1 VE10 10 3489832 MAGNETIC TRIGGER 3500 Q S1 VE100 100...

Страница 9: ...ze ranges A B C G B001 2170 760 730 1020 B003 2400 760 980 1020 B039 1700 760 355 952 B041 1700 760 605 952 B166 1855 760 730 952 B253 2170 760 980 952 B296 2170 760 355 1020 B298 2170 760 605 1020 In...

Страница 10: ...Installation 10 04 2016 KFV 2 2 Pre drilling the operating lever optional Assembly according to the hardware manufacturer s instructions...

Страница 11: ...Installation 11 04 2016 KFV 2 3 Repositioning the latch optional 1 2 3 4...

Страница 12: ...re in mm 12 KFV 2 4 Installing the A opener optional A opener Material number Material description Contents pieces 3493787 F1060 A opener 2 0 1 Read the assembly instructions A opener for the installa...

Страница 13: ...Installation All dimensions are in mm 13 04 2016 KFV 2 5 Installing the door arrester or daytime release optional 314 5 18 150 D 20 16 34 5 D 2 1 Only when using item B A B...

Страница 14: ...ZSK 201 T3 8063 VS35 E 1 3483984 ZSK 201 T3 8063 VS40 E 1 3483985 ZSK 201 T3 8063 VS45 E 1 3483986 ZSK 201 T3 8063 VS50 E 1 3483987 ZSK 201 T3 8063 VS55 E 1 3483988 ZSK 201 T3 8063 VS60 E 1 3483989 Z...

Страница 15: ...2 6 Screwing on the multi point lock 9x Installation 15 04 2016 KFV...

Страница 16: ...2 7 Cutting the door frame Installation All dimensions are in mm 16 KFV...

Страница 17: ...ssembled element with the AS3500 multi point lock including magnetic triggers It is therefore recommended to install the magnetic triggers first when the element is installed on site or prior to trans...

Страница 18: ...2 9 Screwing in the frame parts max 5 mm max 5 mm Installation 18 04 2016 KFV...

Страница 19: ...2 10 Adjusting the frame parts 1 2 3 Installation 19 04 2016 KFV...

Страница 20: ...e lock faceplate Turn the key in the cylinder lock in the opening direction The latch must retract when the key is turned Check the function of the deadbolt Turn the key in the cylinder lock in the lo...

Страница 21: ...lever down vertically and hold down 2 Move the slider up on the faceplate vertically 3 Set the handle of the E opener or the KFV daytime latch 115 A B to daytime operation The AS 3500 multi point lock...

Страница 22: ...AS 3500 multi point lock from 35 to 80 mm In this way the lever handle and the turn button for the safety lock are arranged on a visual axis The metric fixing screws countersunk 8 mm are provided with...

Страница 23: ...ectromechanical opening The deadbolt in the main lock is not locked in this opening procedure The motor is fixed with three screws included If the motor is not installed the screw holes are covered by...

Страница 24: ...the cylinder lock To secure the safe function the key must be turned in the opening direction until it reaches the noticeable stop and held in this position until the door opens by a gap of approx 50...

Страница 25: ...arranty shall become void if modifications that are not authorised by us or have not been described in this documentation are performed on the product and or individual components or if the product an...

Страница 26: ...Appendix 26 04 2016 KFV...

Страница 27: ......

Страница 28: ...tschland Telefon 49 271 39310 Frankreich Telefon 33 3 89618131 Gro britannien Telefon 44 2476 622000 Italien Telefon 39 02 9353601 sterreich Telefon 43 6225 8301 Polen Telefon 48 77 4477700 Russland T...

Отзывы: