background image

ASSEMBLY INSTRUCTIONS

KFV

A-opener 2.2

Electro-mechanical systems

Comfort systems

Door systems

Window systems

Содержание KFV A-Opener 2.2

Страница 1: ...ASSEMBLY INSTRUCTIONS KFV A opener 2 2 Electro mechanical systems Comfort systems Door systems Window systems...

Страница 2: ......

Страница 3: ...Connections and operating elements 7 4 2 Cable and wiring diagram 8 5 INSTALLATION 10 5 1 Installing the A opener 10 5 2 Milling the door leaf 10 5 3 Routing and connecting cables 11 5 3 1 Via the SI...

Страница 4: ...ks with a rigid catch in which the catch is locked in a key withdrawal position inside the range of 30 to 30 with cylinder locks with a non restrictive catch in which the catch can always be freely tu...

Страница 5: ...n designates warning notices that warn of personal injury The type and source of the hazard defines the cause of the hazard The potential consequences of non obser vation of warning notices are e g da...

Страница 6: ...onditions must be observed before and during installation Observe the specified positions and sizes for all milling and drilling dimensions within the defined tolerances Install the A opener 2 2 in ac...

Страница 7: ...e 24 V DC white 2 Analogue connection Terminal 2 output supply voltage 24 V DC Terminal 3 output supply voltage Terminal 4 input for external unlocking signal at 24 V DC 1 seconds opening process 3 Bu...

Страница 8: ...e 230 V AC mains power supply must be carried out in compliance with the current German VDE regula tions e g VDE 0100 and any relevant country specific requirements A opener via SI BUS connection A op...

Страница 9: ...2 2 SN R1 R2 R3 24V DC GND 24V DC GND Input B C D 2 3 4 SI BUS system 1 1s 1s V L N PE V A SI Bus Siemensstr 10 D 42551 Velbert A OPENER 2 2 SN R1 R2 R3 24V DC GND 24V DC GND Input B C D 2 3 4 1 2 3...

Страница 10: ...1 Installing the A opener 3 x M4x11 The A opener 2 2 is supplied unas sembled as standard f f Screw the A opener to a suitable KFV multi point lock using the three screws included in the delivery T 1...

Страница 11: ...urr all holes for the cable routing Do not route cables over sharp edges File or line any sharp edges Route cables without kinking A SI Bus Siemensstr 10 D 42551 Velbert A OPENER 2 2 SN R1 R2 R3 24V D...

Страница 12: ...l unlocking signal 7 Violet Pink Red White 2 24VDC Operating voltage 24 V DC Blue Brown 3 GND Operating voltage White Blue 4 1 2 4 f f Establish a plug connection with the cable type F or E 1 and the...

Страница 13: ...he key in the locking direction until the main deadbolt extends The lever handle is blocked the child proof lock is active f f Turn the key in the unlocking direction until the main deadbolt retracts...

Страница 14: ...rrectly seated If the lever handle does not return to its original posi tion by itself the multi point lock must be checked by KFV 6 4 2 Functional disorder of the profile cylinder f f If you cannot r...

Страница 15: ...P 40 Electrical data Operating voltage UB 24 V DC 19 V DC to 32 V DC Operating current standby standby IST Type 30 mA Operating current for motor control IB Type 500 mA max 1000 mA Reverse polarity pr...

Страница 16: ...t and Certification Authority test report identification number FS 1708 336996 001 The incomplete machine may only be commissioned if it has been ascertained if required that the machine into which it...

Страница 17: ...17 20 Assembly instructions Electro mechanical systems A opener 2 2 17 20 09 2019 H39 ELEKS011EN 00 6 7 Test report Electromagnetic compatibility...