Special Instructions – Methane RH240 / RH360
Lighting the pilot:
1.
Turn wall thermostat to it’s lowest setting
2.
Turn gas cock dial to “OFF” position
3.
WARNING:
Wait at least 5 minutes to allow any gas in the combustion
chamber or burner area to vent. If you smell gas in the appliance area or
near the floor,
STOP
and follow warning instructions on page 4 of this
manual. Failure to do so may result in fire or explosion.
4.
If you don’t smell gas, turn on the gas supply to the H17 pilot valve
(smaller, L.P. valve).
5.
Depress the reset button on the H17 pilot valve and hold.
6.
Light pilot. Continue to depress reset button for 30 – 45 seconds or until
pilot remains burning when the reset button is released.
Lighting the main, methane burner:
7.
With the L.P. pilot burning, turn the main valve gas cock dial to the
“PILOT” position and press momentarily, then turn gas cock dial to “ON”.
8.
The valve should now be configured for normal thermostat control.
Gas Cock
Dial
H17 Pilot
Valve
Reset
Button
Main Burner
Pilot & dual thermocouple assembly
Methane
L.P.
26