FOX SPRAYER OPERATING INSTRUCTIONS
PRIOR TO START UP
Completely uncrate unit. Inspect for shipping damages that could interfere with unit
operation. Check for crating/shipping materials lodged in pump/motor assembly, belt
drive (if applicable) steering mechanism and wheel & tire area. Check for foreign debris
in sprayer tank.
Read this manual and comply with all of the safety instructions. Familiarize yourself with
the operating instructions and component location prior to using the unit.
If you have a gas engine powered unit, read and familiarize yourself with the Honda
Owner’s Manual.
Read and be familiar with the CAT Pump manual and operating instructions.
If electrically powered unit, ensure adequate power and extension cords are available to
operate the unit (see chart below).
MOTOR
HP
100 FT.
200 FT.
300 FT.
500 FT.
115V
230V
115V
230V
115V
230V
115V
230V
1/4
# 14
# 14
# 10
# 12
# 8
# 10
# 6
# 8
1/3
# 12
# 14
# 10
# 12
# 6
# 10
# 4
# 8
1/2
# 10
# 12
# 8
# 10
# 6
# 8
# 4
# 6
3/4
# 10
# 12
# 6
# 10
# 4
# 8
# 2
# 6
1
# 8
# 10
# 6
# 8
# 4
# 6
# 4
1 ½
# 4
# 10
# 0
# 8
# 6
# 4
2
# 8
# 6
# 4
# 2
3
# 8
# 6
# 4
# 2
5
# 6
# 4
# 2
# 0
Wire Size for 115 & 230 Volt Single Phase Circuits
Distance
– Motor to Fuse or Motor to Meter Box
9