background image

8

PJC-222

     

1.0.6 - 2012

PANEL

PANEL SETUP

BACKLIGHT LEVEL

  Set level of panel backlight in daylight mode, 1-5
NIGHTLIGHT - COLOR

   Select color of backlight in nightlight mode:  

  GREEN, BLUE, RED, WHITE
NIGHTLIGHT - LEVEL

  Set level of panel backlight in nightlight mode, 1-3
TIMER AUTO OFF

  Set the time from last use to auto panel shutdown.

  Set from 5-60 minutes in 5 minute steps or OFF (panel will   

  not turn off automatically)
OK: 

Saves changes and returns to main menu

Select:  Selecting parameter

Cancel: Returns to main menu without saving changes
Use stern joystick to change value up or down

DEFAULT

DEFAULT SETTINGS

Reset all settings to factory default - follow instructions on screen

Start:   Resets system to default factory settings

Cancel: Returns to main menu without changes

INFO

INFO

The info selection is a service screen. 

Choose the Info screen if you wish to check your system.          

Use joystick to highlight desired choice.
Select : Selects highlighted info menu.

Back : Returns to main menu. 

 

PANEL INFO

Shows panels firmware version, hardware version, serial number 

and S-Link voltage into the panel.
Back : Returns to Info menu. 
HYDRAULIC INFO

Shows system pressure and oil temperature.

Thruster can be operated with the joystick. 
STOP: Emergency stop – Activates dump valve and Stop thrusters.

Back : Returns to Info menu
AC THRUSTER INFO

Shows AC thruster temperature and rpm for every AC thrusters 

installed. Blank square indicates no AC thruster installed in this 

instance.Thruster can be operated with the joystick. 
STOP: Emergency stop – Stop thrusters.

Back : Returns to Info menu. 

Содержание S-linkControl Panel PJC222

Страница 1: ...r s manual GB Made in Norway Sleipner Motor AS 2012 SLEIPNER MOTOR AS P O Box 519 N 1612 Fredrikstad Norway Tel 47 69 30 00 60 Fax 47 69 30 00 70 w w w s i d e p o w e r c o m sidepower sleipner no PJ...

Страница 2: ...er control units are running the thruster in op posite direction to the hold function the hold function will be deactivated Information display see following pages for details Press and hold ON button...

Страница 3: ...hen the oil level is low the screen will illuminate red a external buzzer will sound a low oil level symbol will appear flash upper left When the oil temperature is higher than 75 C the screen will il...

Страница 4: ...YDRAULIC AC MOTOR POWER PACK TEMP SENSOR The AC motor temp sensor fail symbol will show in the upper right corner if the system is set up with an hydraulic AC motor power pack and the sensor has an op...

Страница 5: ...lluminate red an buzzer will sound the SAC temperature will show with a AL See SAC Manual for more details TEMPERATURE SENSOR FAIL When there is something wrong with the temperature sensor in the SAC...

Страница 6: ...and stop when the oil temp drops below 40 C PUMP 1 PTO mounted Pump 1 can be set to OFF ON or AUTO When pump 1 is set to auto the pump is on when any panel is turned on and off when all panels are of...

Страница 7: ...ystick to alter values Location Can change selected device location between BOW STERN BOW PORT or STERN PORT For PPC800 or SR61242 only use BOW PORT on second bow thruster and STERN PORT on second ste...

Страница 8: ...Resets system to default factory settings Cancel Returns to main menu without changes INFO INFO The info selection is a service screen Choose the Info screen if you wish to check your system Use joys...

Страница 9: ...9 PJC 222 1 0 6 2012 S link System Overview Hydraulic STATION 1 STATION 2 OPTIONAL...

Страница 10: ...10 PJC 222 1 0 6 2012 S link System Overview AC...

Страница 11: ...y 12V 24V DC S link External alarm buzzer 12V 24V DC max 0 5A Internal fuse relay External alarm buzzer connection Rear side of panel Connections for optional external buzzer audible alarm Panel cutou...

Страница 12: ...irona Tel 34 902 300214 Fax 34 902 300215 www imnasa com imnasa imnasa com Sweden Sleipner AB Str mstad Tel 46 526 629 50 Fax 46 526 152 95 www sleipnerab se Switzerland Senero AG Winterthur Tel 41 52...

Отзывы: