Errors shown  

in display

PPC  

800

AMS  

8977

SR80 

SR100

SR130  

SR170 

SR210

Description

Action

Motor 

Overcurrent

X

Motor current over 

1400A

Thruster must be serviced by au-

thorized personel, reset or PPC800 

power OFF/ON

Motor 

Overtemp

X

X

Motor temperature 

have been over 110

o

C

Motor cool down below 100°C

Power 

Overtemp

X

PPC800 temperature 

have been over 80

o

C

PPC800 cool down below 45°C

Power 

Overtemp

X

SR150000 temperature 

have been over 80

o

C

SR150000 cool down below 45°C

Low Power

X

X

X

Low voltage on Motor

Recharge battery, reset or device 

power OFF/ON

Termoswitch

X

X

X

Motor temperature over 

110

o

C

Motor cool down below 100

o

C

IPC Error

X

X

X

Motor relay faulty

Turn off thruster battery main 

switch. Thruster must be serviced 

by authorized personel, power off 

resets alarm.

Driver fail

X

PPC800 fail

PPC800 must be sendt for service

Thruster 

No Current

X

No power to thruster

Check thruster connections or mo-

tor dead!

Thruster 

Relay Fail

X

X

No current on motor 

relay coil

Check motor relay connections, 

short circuit or relay dead!

System Error

X

X

X

X

Fatal error

System must be serviced by  

authorized personnel

Communiction 

Fail

X

X

X

X

No communication with 

device

Check S-link and power connections

Tempsensor 

Fail

X

Motor temperature sen-

sor fail

Check for an open circiut on the 

temp sensor on the motor

Power Failure

X

No power

Check power connections

Fuse Blown

X

Fuse blown

Replace fuse or check if main cable 

from battery and main cable to 

thruster has been switched

Manual 

Override

X

Main switch manually 

overridden

Pull main switch

Deploy 

obstructed

X

X

Retract obstructed 

while deploying

Turn off all panels. Go for lower 

speed/deeper water and retry.

Retract

obstructed

X

X

Retract obstructed 

while retracting

Turn panel on and manually over-

ride main switch. Remove obstruc-

tion and try again.

Power Fail

Actuator

X

X

Actuator not getting 

any power.

Check actuator connection or power 

to actuator.

Pos.Sensor Fail

X

Retract position sensor 

fail

Check position sensor cables and 

for sensor damage.

Not In Running 

Mode

X

Retract not in running 

mode

Check dipswitch setting on retract 

control box.

Error message overview

Содержание S-linkControl Panel PJC211

Страница 1: ...er s manual Made in Norway Sleipner Motor AS 2012 SLEIPNER MOTOR AS P O Box 519 N 1612 Fredrikstad Norway Tel 47 69 30 00 60 Fax 47 69 30 00 70 w w w s i d e p o w e r c o m sidepower sleipner no PJC...

Страница 2: ...ol joystick for thruster Information display see fol lowing pages for details Press both ON buttons simultanously to activate control panel Press to change between day and night light Press and hold f...

Страница 3: ...dure to setup control panels thrusters and additional equipment must be completed before the system can be used SPECIFIC INFORMATION WHEN USED IN A SYSTEM WITH SR SERIES RETRACTABLE THRUSTERS Symbol s...

Страница 4: ...shown when the thruster is obstructed while deploying The internal buzzer will sound Buzzer can be muted by pressing the OFF button Alarm shown when the thruster is obstructed while retracting SPECIF...

Страница 5: ...device location between BOW STERN BOW PORT or STERN PORT For PPC800 or SR61242 only use BOW PORT on second bow thruster and STERN PORT on second stern thruster Direction Can change thruster direction...

Страница 6: ...PLEASE WAIT for a few seconds while the panel is scanning the S link bus for attached equipment This scan can take up to 15 seconds After a completed system scan the thruster with its associated AMS w...

Страница 7: ...ight mode 1 5 NIGHTLIGHT COLOR Select color of backlight in nightlight mode GREEN BLUE RED WHITE NIGHTLIGHT LEVEL Set level of panel backlight in nightlight mode 1 3 TIMER AUTO OFF Set the time from l...

Страница 8: ...ent on motor relay coil Check motor relay connections short circuit or relay dead System Error X X X X Fatal error System must be serviced by authorized personnel Communiction Fail X X X X No communic...

Страница 9: ...nal Power Controller PJC 211 Proportional Joystick Controlpanel Station 2 optional Automatic Main Switch 8977 12 8977 24 or Manual main switch w ANL fuse S link control system End terminator End termi...

Страница 10: ...11 1 1 1 2012 Supply 12V 24V DC S link External alarm buzzer 12V 24V DC max 0 5A Internal fuse relay External alarm buzzer connection Rear side of panel Connections for optional external buzzer audibl...

Страница 11: ...11 PJC 211 1 1 1 2012 Measurements...

Страница 12: ...irona Tel 34 902 300214 Fax 34 902 300215 www imnasa com imnasa imnasa com Sweden Sleipner AB Str mstad Tel 46 526 629 50 Fax 46 526 152 95 www sleipnerab se Switzerland Senero AG Winterthur Tel 41 52...

Отзывы: