background image

 5

PJC-211

      

1.1.1 - 2012

MENU SYSTEM:

Access menu system by pressing Menu button (middle ‘ON’ button) 

for 3 seconds 

Move around in menus by using joysticks

 

Follow instructions on the screen and press buttons as indicated on  

LCD screen

LANGUAGE

SETUP

LANGUAGE

Choose language by moving bow joystick:

English, Norwegian, German, French, Spanish and Italian. 

 

SETUP

Use joystick to choose function

Select: Opens selected function

Cancel: Returns to Main Menu

SYSTEM DEVICES

View all devices connected to S-Link and manually change setup 

values. 

Slide between devices with the joystick to see device information as 

location, thruster direction, retract type, firmware version and serial 

number. 
Edit:     Change location to BOW, STERN, BOW-PORT or STERN-

PORT, thruster direction to Normal or Inverted or retract 

type. For Automatic main switch 1 8977 and interface 8730, 

you can only change location. Use joystick to alter values.

            

Location:

 

 

Can change selected device location between BOW , STERN, 

BOW-PORT or STERN-PORT. For PPC800 or SR61242 only. 

(use BOW-PORT on second bow thruster and STERN-PORT 

on second stern thruster)

            

Direction:

 

 

Can change thruster direction to Normal or Inverted. Change 

this value if the thruster is running in the wrong direction. 

For PPC800 or SR61242 only.

            

 

Retract:

  

 

Setup retract types. For PPC800 or SR61242 only.

             

Normal:

  stand alone,use this for PPC800 without any  

 

   

retract or SR61242 (SR80/100) without   

 

   

PPC800 or SR150000 (SR130/170/210)  

 

   

without PPC800.

              

Type 1:

  Retract SR61242 (SR80/100) with PPC800,  

 

   

both devices needs to be set to Type 1. 

 

 

Type 2:

  Retract SR150000(SR130/170/210) with  

 

   

PPC800, both devices needs to be set to 

 

 

   

Type 2   

 

WHEN INSTALLING A RETRACT THRUSTER WITH 

SPEED CONTROL (PPC800), DO NOT TRY TO RUN THE 

THRUSTER UNTIL YOU HAVE COMPLETED THE ENTIRE 

SETUP PROCEDURE CORRECTLY!

 

 

 

This is to prevent damage to the thruster caused by running 

the thruster while the retract mechanism is not fully opened.  

 

OK

Saves changes and quit editing.

            

Select

:  Switch between Location, Retract and Retract settings.

            

Cancel

: Cancel operation without saving changes.

Cancel: Returns to “SETUP” –menu.

NB!

NB!

Содержание S-linkControl Panel PJC211

Страница 1: ...er s manual Made in Norway Sleipner Motor AS 2012 SLEIPNER MOTOR AS P O Box 519 N 1612 Fredrikstad Norway Tel 47 69 30 00 60 Fax 47 69 30 00 70 w w w s i d e p o w e r c o m sidepower sleipner no PJC...

Страница 2: ...ol joystick for thruster Information display see fol lowing pages for details Press both ON buttons simultanously to activate control panel Press to change between day and night light Press and hold f...

Страница 3: ...dure to setup control panels thrusters and additional equipment must be completed before the system can be used SPECIFIC INFORMATION WHEN USED IN A SYSTEM WITH SR SERIES RETRACTABLE THRUSTERS Symbol s...

Страница 4: ...shown when the thruster is obstructed while deploying The internal buzzer will sound Buzzer can be muted by pressing the OFF button Alarm shown when the thruster is obstructed while retracting SPECIF...

Страница 5: ...device location between BOW STERN BOW PORT or STERN PORT For PPC800 or SR61242 only use BOW PORT on second bow thruster and STERN PORT on second stern thruster Direction Can change thruster direction...

Страница 6: ...PLEASE WAIT for a few seconds while the panel is scanning the S link bus for attached equipment This scan can take up to 15 seconds After a completed system scan the thruster with its associated AMS w...

Страница 7: ...ight mode 1 5 NIGHTLIGHT COLOR Select color of backlight in nightlight mode GREEN BLUE RED WHITE NIGHTLIGHT LEVEL Set level of panel backlight in nightlight mode 1 3 TIMER AUTO OFF Set the time from l...

Страница 8: ...ent on motor relay coil Check motor relay connections short circuit or relay dead System Error X X X X Fatal error System must be serviced by authorized personnel Communiction Fail X X X X No communic...

Страница 9: ...nal Power Controller PJC 211 Proportional Joystick Controlpanel Station 2 optional Automatic Main Switch 8977 12 8977 24 or Manual main switch w ANL fuse S link control system End terminator End termi...

Страница 10: ...11 1 1 1 2012 Supply 12V 24V DC S link External alarm buzzer 12V 24V DC max 0 5A Internal fuse relay External alarm buzzer connection Rear side of panel Connections for optional external buzzer audibl...

Страница 11: ...11 PJC 211 1 1 1 2012 Measurements...

Страница 12: ...irona Tel 34 902 300214 Fax 34 902 300215 www imnasa com imnasa imnasa com Sweden Sleipner AB Str mstad Tel 46 526 629 50 Fax 46 526 152 95 www sleipnerab se Switzerland Senero AG Winterthur Tel 41 52...

Отзывы: