User’s manual TM200B
8
5.4.
ELECTRICAL CONNECTION
Only low voltage trained and authorized technicians should be allowed to perform interventions on the electric circuit.
POWER
Make sure the voltage of the motor matches the voltage of
the main power.
Perform the connection, using the power cable.
The power socket must match the plug of the grinder.
The machine is connected to a power system. This system
must be connected to earth, according to in-force safety
regulations.
We remind the user that a magneto thermal breaker must
be installed before the electrical circuit to protect all
conductive devices against short-circuits and overloads.
This protection should always be selected according to the
electrical specifications of the machine, as stated on the
rate plate :
Voltage : one-phase 230 V
Frequency : 50 Hz
Rate : 3,9 A
Main motor power : 0,9 kW
Power connections and extensions must be protected
against splashes and should be fitted onto dry surfaces.
Regularly inspect condition of the power chord, of the switch
and of the cable duct.
Operating the grinder, using a damaged power chord, is strictly prohibited.
Always use a cable winder with both section and length adapted to the power of the machine. Unwind completely the
cable.
Never pull the cable to unplug the grinder. Always use the plug.
Make sure that direction of both wheel and wire wheel rotations match the arrow displayed by the wheel and the wire
wheel housings. The guarantee does not cover damages resulting from a poor connection.
5.5.
DRY TEST AND INITIAL INSPECTION PRIOR TO USING THE EQUIPMENT FOR THE FIRST TIME
Make sure all protections are in place and in
working condition.
Make sure moving parts correctly run and that no
part is damaged.
Check condition of the wheel and the wire wheel.
Make sure the grinder is correctly fixed to the
bench or to its support and that the support is
correctly fixed to the ground.
Perform a dry test : the machine should run
correctly.