Function
Minimum duration
External teach-in Q2
3.5
Alignment
Align the sensor with the object. Select the position so that the red emitted light beam
hits the center of the object. You must ensure that the optical opening (front screen) of
the sensor is completely clear [F]. We recommend making the adjustments using an
object with a low remission.
Figure: E
4
Configuration
Perform configuration:
4.1
Setting the switching output via the teach-in quick access button (-/Q1) (+/Q2)
The sensing range is adjusted by pressing the teach-in quick access button for > 1 s.
Do not operate the teach-in buttons using sharp objects. We recommend placing the
sensing range in the object, e.g., see Graphic F. Once the sensing range has been
adjusted, the object is removed from the path of the beam. This causes the background
to be suppressed and the switching output to change.
Sensing range settings via IO-Link. See IO-Link description (8024109).
The sensor is adjusted and ready for operation. Use the following graphic to check the
function. If the switching output fails to behave in accordance with the graphic, check
the application conditions. See section Fault diagnosis
Figure: F
3
COMMISSIONING