background image

1.

2.

3.

Figure 4: Reference points

The size of the object must be taken into account when positioning the switching point, 

see

figure 4

.

The positioning procedure is carried out as follows:

Point determination
1.

Move the tool into the WFZ until a switching output switches

2.

Move the tool sideways until the second switching output switches

3.

Move back to the central position and then move towards the center of the fork until
the crossing point is reached and both switching outputs switch

1

2

3

Figure 5: Point determination at the object tip

The alignment of the tool on the Z axis can also be ascertained by repositioning the tool on
the Z axis after point determination has been carried out (Step 4, 5 and 6).

COMMISSIONING 

6

8023382.14JZ | SICK

Subject to change without notice

9

Содержание WFZ

Страница 1: ...O P E R A T I N G I N S T R U C T I O N S WFZ Fork sensors...

Страница 2: ...O P E R A T I N G I N S T R U C T I O N S WFZ Fork sensors de en...

Страница 3: ...t is only permissible within the limits of the legal determination of Copyright Law Any modifica tion abridgment or translation of this document is prohibited without the express writ ten permission o...

Страница 4: ...ating elements and status indicators 6 4 Mounting 7 5 Electrical installation 7 5 1 DC 8 6 Commissioning 8 7 Troubleshooting 10 8 Disassembly and disposal 11 9 Maintenance 11 10 Technical data 11 CONT...

Страница 5: ...1 Maximum pulse power 2 5 mW Puls length 4 s Wavelength 650 670 nm Complies with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice No 50 dated June 24 2007 ATTENTION WARNING I...

Страница 6: ...tection axis 3 Male connector M12 5 pin 4 Fixing hole 5 4 mm 5 LED indicator green supply voltage active 6 LED indicator yellow Status of received light beam Q2 7 LED indicator yellow Status of receiv...

Страница 7: ...screws are to be used This requires an absolute flat mounting surface to avoid twisting of the sensor The reference points of the respective fixing holes to the crossed light beam can be seen in the...

Страница 8: ...s is interrupted this is signaled by the respective switching behavior of Q1 Q2 If light beam 1 is interrupted switching output Q1 pin 4 is deactivated If light beam 2 is interrupted switching output...

Страница 9: ...ways until the second switching output switches 3 Move back to the central position and then move towards the center of the fork until the crossing point is reached and both switching outputs switch 1...

Страница 10: ...1 s The yellow LEDs flash during the teach in procedure NOTE For maximum accuracy we recommend using the teach in function before every measure ment At least however after initial commissioning of th...

Страница 11: ...to the applicable country specific regula tions Efforts should be made during the disposal process to recycle the constituent materials particularly precious metals NOTE Disposal of batteries electri...

Страница 12: ...Ambient operating temperature 10 C 50 C5 Storage temperature 30 C 65 C 1 Limit value operation in short circuit protection mains max 8 A residual ripple max 5 Vss 2 Without load 3 With light dark rat...

Страница 13: ...3 Fixing hole 5 4 mm 4 LED indicator TECHNICAL DATA 10 8023382 14JZ SICK Subject to change without notice 13...

Страница 14: ...B E T R I E B S A N L E I T U N G WFZ Gabelsensoren de en...

Страница 15: ...ks ist nur in den Grenzen der gesetzlichen Bestimmungen des Urheberrechtsgesetzes zul s sig Jede nderung K rzung oder bersetzung des Werks ohne ausdr ckliche schriftli che Zustimmung der Firma SICK AG...

Страница 16: ...dung 17 13 Bedien und Anzeigeelemente 18 14 Montage 19 15 Elektrische Installation 19 15 1 DC 20 16 Inbetriebnahme 20 17 St rungsbehebung 22 18 Demontage und Entsorgung 23 19 Wartung 23 20 Technische...

Страница 17: ...llenl nge 650 670 nm Entspricht 21 CFR 1040 10 und 1040 11 mit Ausnahme von Abweichungen nach Laser Hinweis 50 24 Juni 2007 ACHTUNG ACHTUNG Eingriffe oder Manipulationen oder nicht bestimmungsgem e Ve...

Страница 18: ...ere Seite 2 Detektionsachse 3 Stecker M12 5 polig 4 Befestigungsbohrung 5 4 mm 5 Anzeige LED gr n Betriebsspannung aktiv 6 Anzeige LED gelb Status Lichtempfang Q2 7 Anzeige LED gelb Status Lichtempfan...

Страница 19: ...che eben ist HINWEIS Um die maximale Vibrationsfestigkeit zu erreichen m ssen alle sechs Befestigungs bohrungen verwendet werden Dies erfordert eine absolut ebene Montagefl che um ein Verdrehen des S...

Страница 20: ...s Unterbrechen eines der beiden gekreuzten Lichtstrahlen wird durch das jeweilige Schaltverhalten Q1 Q2 signalisiert Wird der Lichtstrahl 1 unterbrochen so wird der Schaltausgang Q1 pin 4 deaktiviert...

Страница 21: ...der zweite Schaltausgang schaltet 3 Zur ck zur mittleren Position bewegen und anschlie end Richtung Gabelmitte bewe gen bis der Kreuzungspunkt erreicht ist und beide Schaltausg nge schalten 1 2 3 Abb...

Страница 22: ...s blinken die gelben LED Anzeigen HINWEIS Es wird empfohlen f r die maximale Messgenauigkeit die Teach in Funktion vor jeder Mes sung durchzuf hren Mindestens aber nach der Erstinbetriebnahme des Sens...

Страница 23: ...uss entsprechend den geltenden l nderspezifischen Vorschriften entsorgt werden Bei der Entsorgung sollte eine werkstoffliche Verwertung insbeson dere der Edelmetalle angestrebt werden HINWEIS Entsorgu...

Страница 24: ...max 1 000 Hz3 Reproduzierbarkeit 0 01 mm Ansprechzeit max 0 5 ms4 Initialisierungszeit 50 ms Schutzart IP67 Schutzklasse III Betriebsumgebungstemperatur 10 C 50 C5 Lagertemperatur 30 C 65 C 1 Grenzwer...

Страница 25: ...63 100 220 167 156 100 113 78 3 3 1 25 2 4 3 Abbildung 16 Ma zeichnung 1 Detektionsachsen 2 Stecker M12 5 polig 3 Befestigungsbohrung 5 4 mm 4 Anzeige LED TECHNISCHE DATEN 20 8023382 14JZ SICK Subjec...

Страница 26: ...3 8080 7425 E Mail enquiry my sick com Mexico Phone 52 472 748 9451 E Mail mexico sick com Netherlands Phone 31 0 30 229 25 44 E Mail info sick nl New Zealand Phone 64 9 415 0459 0800 222 278 tollfree...

Отзывы: