Explanations of the connection diagram (Tables 2–7):
Q = switching outputs
5.1
DC
DC: 10 V ... 30 V DC,
Table 1: DC
WFZ
1
BN
+ (L+)
2
WH
Q2
3
BU
- (M)
4
BK
Q1
5
GY
ET
1
2
5
4
3
6
Commissioning
1
Alignment: Positioning of objects in the crossed light beams
If one of the two crossed light beams is interrupted, this is signaled by the respective
switching behavior of Q1/Q2.
If light beam 1 is interrupted, switching output Q1 (pin 4) is deactivated.
If light beam 2 is interrupted, switching output Q2 (pin 2) is deactivated.
If an object covers both light beams, light beams 1+2 are interrupted and signaled by
switching outputs Q1 + Q2.
3
1
2
Figure 3: Switching outputs
1
Light beam 1, Q1
2
Light beam 2, Q2
3
Crossing point
5
ELECTRICAL INSTALLATION
8
8023382.14JZ | SICK