Figure 7: Time functions
9
Devices with special features
WS/WE34-B43S01: preset to dark switching
10
Troubleshooting
The Troubleshooting table indicates measures to be taken if the sensor stops working.
Table 9: Troubleshooting
LED indicator/fault pattern
Cause
Measures
Yellow LED does not light up
even though the light beam is
aligned to the receiver and
there is no object in the path of
the beam
No voltage or voltage below
the limit values
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Voltage interruptions
Ensure there is a stable power
supply without interruptions
Sensor is faulty
If the power supply is OK,
replace the sensor
No object in beam path, no out‐
put signal
Test input (Test) is not con‐
nected properly
Check connection of the test
input. When using female
cable connectors with LED
indicators, make sure the test
input is assigned correspond‐
ingly.
Yellow LED flashes; if Alarm is
present then take note of the
corresponding output signal
Sensor is still ready for opera‐
tion, but the operating condi‐
tions are not ideal
Check operating conditions:
align light beam (light stop)
completely on the receiver/
cleaning of optical surfaces /if
potentiometer is set to max.
sensitivity: reduce distance
between sender and
receiver /Check sensing range
and adjust if necessary.
9
DEVICES WITH SPECIAL FEATURES
12
8009200.11O1 | SICK
Subject to change without notice
Содержание WE34
Страница 88: ...WS WE34 en de fr pt it es zh ja ru de en es fr it ja pt ru zh...
Страница 102: ...WS WE34 en de fr pt it es zh ja ru de en es fr it ja pt ru zh...
Страница 116: ...WS WE34 en de fr pt it es zh ja ru de en es fr it ja pt ru zh...
Страница 128: ...C 115 116 SICK 115 128 8009200 11O1 SICK Subject to change without notice...