Figure 4: Alignment
2
Sensing range
Observe application conditions: adjust the distance between the sensor and the reflector
according to the corresponding diagram [see
] (x = sensing range, y = operating
reserve).
If several through-beam photoelectric sensors which are installed next to one another are
to be used, we recommend swapping the sender/receiver arrangement at every second
through-beam photoelectric sensor and ensuring that there is sufficient distance between
the through-beam photoelectric sensors. By doing this, mutual interference can be pre‐
vented [see
].
100
10
1
sensing range
typ. max. sensing range
m
10
20
30
40
50
60
Figure 5: Characteristics
0
10
(32.81)
20
(65.62)
30
(98.43)
40
(131.23)
50
(164.04)
60
(196.85)
Distance in m (feet)
Sensing range
Sensing range max.
50
60
0
Figure 6: Bar graph
3
Sensitivity setting
Sensor with potentiometer: open the sensor cover and protective hood, make sure that no
dirt has gotten into the sensor.
The sensitivity is adjusted with the potentiometer (type: without stop). Clockwise rotation:
operating reserve increased; counterclockwise rotation: operating reserve reduced. We rec‐
ommend setting the potentiometer to “Maximum”.
The sensor is adjusted and ready for operation.
4
Time function setting
WSE24-2xx4x: t0= no time delay, t1 = time delay, t2 = time delay; for -2R: 0 = relay deacti‐
vated, 1 = relay active. Time delay selector switch can be set on the device according to the
following graphic.
Time stages: 0.5 ... 10 s can be adjusted.
COMMISSIONING
8
8008782.14BT | SICK
Subject to change without notice
11
Содержание WE-2B 4 Series
Страница 88: ...WS WE24 2 en de fr pt it es zh ja ru de en es fr it ja pt ru zh...
Страница 102: ...WS WE24 2 en de fr pt it es zh ja ru de en es fr it ja pt ru zh...
Страница 116: ...WS WE24 2 en de fr pt it es zh ja ru de en es fr it ja pt ru zh...
Страница 128: ...C Health 115 116 SICK 115 128 8008782 14BT SICK Subject to change without notice...