SYSTEM DESCRIPTION
3
53
8026365/V1-0/2022-03|SICK
Subject to change without notice
S U P P L E M E N T A R Y O P E R A T I N G I N S T R U C T I O N S | VMS4200-x/5200-x MID
3.9.2
Security seal
In order to protect measurement systems that have been verified as legal for trade
against manipulation, all legally relevant components that influence the measurement
result must be provided with seals in accordance with the seal diagram depicted in the
figure below.
The security seals are attached to the VMS5200-x MID components after mounting and
the conformity assessment.
NOTE!
Never break any seals. A broken seal causes the legal for trade calibration period
to end ahead of schedule. The VMS5200-x MID is then no longer permitted to be used for
billing purposes.
▸
The incident must be reported to the manufacturer and the office of weights and
measures.
Security seals prevent the attachment mechanism of the LiDAR sensors and the plug
connections of the connections from misaligning.
Fig. 48: Security seal on the LiDAR sensors of the VMS5200-x MID
Legend
1
Security seal on the mounting plate of the modular bracket on the frame
2
Security seal on the two adjusters of the telescopic tube
3
Security seal on the mounting plates of the LiDAR sensors
4
Security seal on all plug connections for the electrical connections
Seal on the LiDAR
sensor