3
Product description
3.1
Scope of delivery
Scope of delivery
No. of
units
Component
Note
1
Device in the version ordered
-
1
Terminal bracket
-
1
Printed safety notes, multilingual
Brief information and general safety notes
Further topics
•
The actual scope of delivery may differ for special designs, additional orders or due to
the latest technical changes.
3.2
Type code
Type code structure
UC40 – a b c d e f
Position
Description
Characteristic
a
Generation
1: 1. Generation
b
Principle of operation
1: Button operation
c
Operating range
2: 65 mm ... 350 mm
3: 200 mm ... 1,300 mm
4: 350 mm ... 3,400 mm
d
Connection technology 1: male connector, M12, 5-pin
e
Housing material
1: PA66 plastic
f
Output function
B: 1 output
•
1 push-pull digital output with IO-Link 1.1
H: 2 outputs
•
1 push-pull digital output with IO-Link 1.1
•
1 analog output (current and voltage) or push-pull
digital output with IO-Link 1.1 (selectable)
3
PRODUCT DESCRIPTION
10
O P E R A T I N G I N S T R U C T I O N S | UC40
8027772//2022-08-11 | SICK
Subject to change without notice