Technical Information
Chapter
4
TiM3xx
Electrical installation
8014318/YK97/2015-04-27
© SICK AG · Germany · All rights reserved · Subject to change without notice
27
4.5.3
Wiring of switching outputs OUT 1 to OUT 4
Switching outputs OUT 1 to OUT 3 signal in combination infringement of the individual fields
of a field set (combinatorics table
see TiM3xx operating instructions
). Output OUT 4 is used
to output an error and a regular index pulse.
PNP variant:
NPN variant (TIM3XX-XXXXXXXXS02):
Characteristic data of all switching outputs is identical.
TiM3xx
V
S
= DC 9 ... 28 V
OUT 1
Structure and wiring principle of output
OUT 2 (pin 13), OUT 3 (pin 14) and
OUT 4 (pin 4) same as output OUT 1
12
5
GND
V
out
Quenching circuit:
Install an anti-surge
diode directly at the
load!
For inductive load:
TiM3xx
OUT 1
12
5
GND
1
V
S
V
S
Quenching circuit:
Install an anti-surge
diode directly at the
load!
For inductive load:
Structure and wiring principle of output
OUT 2 (pin 13), OUT 3 (pin 14) and
OUT 4 (pin 4) same as output OUT 1
V
S
= DC 9 ... 28 V
V
out