1
2
1
Device
2
Laser pulse
0
60
120
180
240
300
0
2000
3000
5000
7000
4000
6000
9000
8000
1000
10000
Range (mm)
2
Spot diameter (mm)
1
Spot diameter of a submeasuring point.
Divergence 9 mrad, spot diameter on the front screen 6 mm
3
Elongation of the overlayed submeasuring points in direction of deflection
at angle step 1°.
Divergence 26.5 mrad, spot diameter on the front screen 6 mm
4
1
Spot diameter (mm)
2
Range (mm)
3
Spot diameter of a submeasuring point.
Divergence 9 mrad, spot diameter on the front screen 6 mm
4
Elongation of the overlayed submeasuring points in direction of deflection at angle step
1°.
Divergence 26.5 mrad, spot diameter on the front screen 6 mm
3.2
Particle filter
By using a digital particle filter to pre-process and optimize the measured distance
values, the device can be tailored to the specific requirements of the respective appli‐
cation.
The particle filter blanks small, irrelevant reflection pulses in dusty environments which
are caused by dust particles or the like. In doing so, successive scans are continuously
evaluated in order to detect static objects.
PRODUCT DESCRIPTION
3
8020631/1DWW/2022-08 | SICK
O P E R A T I N G I N S T R U C T I O N S | TiM1xx
11
Subject to change without notice