Feature
Parameter
CAN
Quantity
1
Function
SICK CAN sensor network (master/slave, multi‐
plexer/server) with termination resistor which can be
activated
1 x CAN (IN/OUT) not isolated
Data transmission rate
20 kbit/s to 1 Mbit/s
Protocol
CSN (SICK CAN sensor network)
IO-Link master
Quantity
4 x IO-Link to X1 male connector
Data transmission rate
max. 230 kBaud
Protocol
IO-Link master 1.1
Digital switching inputs/outputs
X1
4 configurable inputs/out‐
puts incl. IO-Link
4 inputs
X3
4 isolated outputs (high side)
X4
4 isolated inputs
X5
4 isolated inputs
USB
AUX (USB 2.0) for configuration/diagnostics
11.3
Mechanics and electronics
Feature
Parameter
Optical indicators
31 x green status indicators
3 x blue status indicators
6 x green Link indicators
6 x orange activity indicators
9 x red/green device status indicators
Operating elements
1 selector switch present under the servicing panel
2 S1 and S2 switches for GND ISO/GND
Electrical connection
X1 – IO-Link, GPIOs: spring terminals
X2 – POWER: spring terminals
X3 – OUTPUT: spring terminals
X4 – INPUT A: spring terminals
X5 – INPUT B: spring terminals
X6 – SERIAL A: spring terminals
X7 – SERIAL B: spring terminals
X8 – CAN: spring terminals
X9 to X14: RJ-45
Supply voltage
24 V DC, ± 10% SELV in accordance with EN 61010, also applies
to digital inputs
Operating current
Must be limited by external power supply unit to max. 5 A
Power consumption
Typ. 20 W, without connected sensors
Power output
Max. 50 W (input A & B, IO-Link)
Output current for switch‐
ing outputs
X1: 100 mA per output
X3: 700 mA in total
Output current for supply
voltages
X1: max. 700 mA
X4, X5: 700 mA in total
11
TECHNICAL DATA
38
O P E R A T I N G I N S T R U C T I O N S | SIM2000ST
8020764/1FTA/2022-05-02 | SICK
Subject to change without notice